Well Details

Well ID: 115-20229
Loading map...
County: Susquehanna
Municipality: Springville Township
Operator Name: CHIEF OIL & GAS LLC
Farm/Lease Name: TEEL UNIT 3H
First Permit Date: 2009-10-05
Last Permit Date: 2009-10-05
Spud Date: 2010-01-07
Unconventional: Yes
Horizontal: Yes
Producing: Yes
Violations: 2
Latitude: 41.700827
Longitude: -75.889816

Well Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
1852641 2009-11-18 No Violations Noted
1863072 2010-02-05 Violation(s) Noted Drilling long string. depth at 6161'. Drillers log not filled out up to date. Only filled out to depth of surface casing. 581257
1895955 2010-06-30 Violation(s) Noted No activity on site. Reserve pit still present. Fence around pit needs repair. Four 55-gallon steel drums on southern portion of pad. One drum leaking onto ground. Drums labeled gear oil. Violation cited for unpermitted discharge of industrial waste to ground. Also noted poly tanks lined along pad 590690
1899611 2010-07-21 Outstanding Violations - No Viols Req'd : I arrived on site at approximately 8:00 am. At the time of inspection, there was no activity on site. The purpose of the inspection was to follow up on violations observed during an inspection completed on June 30, 2010. Based on my inspection, I observed the following: the four drums (including the leaking drum) of gear oil have been removed; the two drums labeled non-regulated waste have been removed; and the poly totes that were along the edge of the pad have also been removed from the site. Upon inspection of the ground surface in the area where the leaking drum was located, there is evidence of impacted soil still present. Remediation of this area which included removal of impacted soils is still required.
As requested on the June 30th inspection, the existing fence around the reserve pit has not been repaired and/or maintained.  According to 78.56(a) 3, ¿pits¿shall be¿ reasonably protected from unauthorized acts of third parties.¿  

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-2 313960.0 181.0 0.0 0.0 0.0 0.0
2012-1 438792.79 182.0 0.0 0.0 0.0 0.0
2011-2 644771.0 180.0 0.0 0.0 0.0 0.0
2011-1 839194.0 157.0 0.0 0.0 0.0 0.0
2010-2 1417439.0 175.0 0.0 0.0 0.0 0.0
2010-3 266976.0 37.0 0.0 0.0 0.0 0.0
2009-0 0.0 0.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-2 PRODUCED FLUID 153.7 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR HYDRAULIC FRACTURING
2010-2 DRILLING FLUID WASTE 2584.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119 EUREKA RESOURCES (WILLIAMSPORT WATER TREATMENT) WILLIAMSPORT PA
2010-2 FRACING FLUID WASTE 1633.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119 EUREKA RESOURCES (WILLIAMSPORT WATER TREATMENT) WILLIAMSPORT PA
2010-2 DRILLING FLUID WASTE 1682.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451 SUNBURY GENERATION WASTE WATER TRMT FAC SHAMOKIN DAM PA
2010-2 PRODUCED FLUID 643.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451 SUNBURY GENERATION WASTE WATER TRMT FAC SHAMOKIN DAM PA
2011-1 FRACING FLUID WASTE 509.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451 SUNBURY GENERATION WASTE WATER TRMT FAC SHAMOKIN DAM PA
2012-1 PRODUCED FLUID 332.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR HYDRAULIC FRACTURING