If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-115-20594 | | Well ID: 37-115-20594 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.688636, -75.922086 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 08 | + | | Spud Date: 2011-08-01 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2011-06-17 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2012-10-29 | ||
+ | | 2012-10-29 | ||
+ | | style="text-align: right;" | 5652.00 | ||
+ | | style="text-align: right;" | 105840.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="14"| 1 | ||
+ | | rowspan="1"| Sand, White, 40/70 | ||
+ | | rowspan="1"| Baker Hughes | ||
+ | | rowspan="1"| Proppant | ||
+ | | Quartz | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 1.00 | ||
+ | | style="text-align: right;" | 0.04 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| Alpha 1427 | ||
+ | | rowspan="4"| Baker Hughes | ||
+ | | rowspan="4"| Biocide | ||
+ | | Didecyl dimethyl ammonium chloride | ||
+ | | 7173-51-5 | ||
+ | | style="text-align: right;" | 0.10 | ||
+ | | style="text-align: right;" | 0.00002000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Quaternary ammonium compounds,<br/> benzyl-C12-16-alkyldimethyl, chlorides | ||
+ | | 68424-85-1 | ||
+ | | style="text-align: right;" | 0.05 | ||
+ | | style="text-align: right;" | 0.00001000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Glutaraldehyde | ||
+ | | 111-30-8 | ||
+ | | style="text-align: right;" | 0.30 | ||
+ | | style="text-align: right;" | 0.00007000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Ethanol | ||
+ | | 64-17-5 | ||
+ | | style="text-align: right;" | 0.05 | ||
+ | | style="text-align: right;" | 0.00001000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| Scaletrol 720 | ||
+ | | rowspan="2"| Baker Hughes | ||
+ | | rowspan="2"| Scale Inhibitor | ||
+ | | Calcium chloride | ||
+ | | 10043-52-4 | ||
+ | | style="text-align: right;" | 0.05 | ||
+ | | style="text-align: right;" | 0.00001000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Ethylene glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 0.30 | ||
+ | | style="text-align: right;" | 0.00008000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| Operator | ||
+ | | rowspan="1"| Carrier | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 1.00 | ||
+ | | style="text-align: right;" | 0.90 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| Superset-W | ||
+ | | rowspan="2"| Baker Hughes | ||
+ | | rowspan="2"| Activator | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 0.50 | ||
+ | | style="text-align: right;" | 0.00085000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Nonyl phenol ethoxylate | ||
+ | | 9016-45-9 | ||
+ | | style="text-align: right;" | 0.50 | ||
+ | | style="text-align: right;" | 0.00085000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| Super LC, 30/50 | ||
+ | | rowspan="3"| Baker Hughes | ||
+ | | rowspan="3"| Proppant | ||
+ | | Quartz | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 0.97 | ||
+ | | style="text-align: right;" | 0.04 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Phenolic resin | ||
+ | | 9003-35-4 | ||
+ | | style="text-align: right;" | 0.05 | ||
+ | | style="text-align: right;" | 0.00249000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Methenamine | ||
+ | | 100-97-0 | ||
+ | | style="text-align: right;" | 0.00010000 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| FRW-18 | ||
+ | | rowspan="1"| Baker Hughes | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Distillates, petroleum, hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 0.30 | ||
+ | | style="text-align: right;" | 0.00019000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 156: | Line 305: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2011- | + | | 2011-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 5.69 Tons | | style="text-align: right;" | 5.69 Tons | ||
Line 162: | Line 311: | ||
| 100081 | | 100081 | ||
|- | |- | ||
− | | 2011- | + | | 2011-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 194.32 Tons | | style="text-align: right;" | 194.32 Tons | ||
Line 168: | Line 317: | ||
| 101247 | | 101247 | ||
|- | |- | ||
− | | 2011- | + | | 2011-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 7.47 Tons | | style="text-align: right;" | 7.47 Tons | ||
Line 174: | Line 323: | ||
| 101534 | | 101534 | ||
|- | |- | ||
− | | 2011- | + | | 2011-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 3,320.09 Tons | | style="text-align: right;" | 3,320.09 Tons | ||
Line 180: | Line 329: | ||
| THR029 | | THR029 | ||
|- | |- | ||
− | | 2011- | + | | 2011-S02 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 4,722.57 Bbl | | style="text-align: right;" | 4,722.57 Bbl | ||
Line 186: | Line 335: | ||
| | | | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Basic Sediment (in Barrels) | | Basic Sediment (in Barrels) | ||
| style="text-align: right;" | 0.74 Bbl | | style="text-align: right;" | 0.74 Bbl | ||
Line 192: | Line 341: | ||
| THR029 | | THR029 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 124.76 Tons | | style="text-align: right;" | 124.76 Tons | ||
Line 198: | Line 347: | ||
| 301626 | | 301626 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 717.17 Bbl | | style="text-align: right;" | 717.17 Bbl | ||
Line 204: | Line 353: | ||
| THR029 | | THR029 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 1,986.67 Bbl | | style="text-align: right;" | 1,986.67 Bbl | ||
Line 210: | Line 359: | ||
| WMGR123NE001 | | WMGR123NE001 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 7,345.37 Bbl | | style="text-align: right;" | 7,345.37 Bbl | ||
Line 216: | Line 365: | ||
| | | | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 12.16 Tons | | style="text-align: right;" | 12.16 Tons | ||
Line 222: | Line 371: | ||
| THR029 | | THR029 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 79.60 Bbl | | style="text-align: right;" | 79.60 Bbl | ||
Line 228: | Line 377: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 54.64 Bbl | | style="text-align: right;" | 54.64 Bbl | ||
Line 234: | Line 383: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 188.76 Bbl | | style="text-align: right;" | 188.76 Bbl | ||
Line 240: | Line 389: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 165.76 Bbl | | style="text-align: right;" | 165.76 Bbl | ||
Line 246: | Line 395: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 9.00 Bbl | | style="text-align: right;" | 9.00 Bbl | ||
Line 252: | Line 401: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 17.50 Bbl | | style="text-align: right;" | 17.50 Bbl | ||
Line 258: | Line 407: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.64 Tons | | style="text-align: right;" | 0.64 Tons | ||
Line 264: | Line 413: | ||
| 101247 | | 101247 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M05 |
| Waste Water Treatment Sludge (in Tons) RWC 804 | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
| style="text-align: right;" | 4.78 Tons | | style="text-align: right;" | 4.78 Tons | ||
Line 270: | Line 419: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 5.60 Bbl | | style="text-align: right;" | 5.60 Bbl | ||
Line 276: | Line 425: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 2.27 Bbl | | style="text-align: right;" | 2.27 Bbl | ||
Line 282: | Line 431: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Waste Water Treatment Sludge (in Tons) RWC 804 | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
| style="text-align: right;" | 0.72 Tons | | style="text-align: right;" | 0.72 Tons | ||
Line 288: | Line 437: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 11.95 Bbl | | style="text-align: right;" | 11.95 Bbl | ||
Line 294: | Line 443: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 0.39 Bbl | | style="text-align: right;" | 0.39 Bbl | ||
Line 300: | Line 449: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 187.45 Bbl | | style="text-align: right;" | 187.45 Bbl | ||
Line 306: | Line 455: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 0.85 Bbl | | style="text-align: right;" | 0.85 Bbl | ||
Line 331: | Line 480: | ||
| 1990340 | | 1990340 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2011-07-22 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 338: | Line 487: | ||
| 2000375 | | 2000375 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2011-08-25 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 345: | Line 494: | ||
| 2005264 | | 2005264 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2011-09-21 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 352: | Line 501: | ||
| 2007054 | | 2007054 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2011-08-23 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 359: | Line 508: | ||
| 2007193 | | 2007193 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2011-09-27 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 366: | Line 515: | ||
| 2007204 | | 2007204 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2011-08-29 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 373: | Line 522: | ||
| 2007235 | | 2007235 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2011-08-25 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 380: | Line 529: | ||
| 2009267 | | 2009267 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2011-10-03 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 387: | Line 536: | ||
| 2012667 | | 2012667 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2011-10-19 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 394: | Line 543: | ||
| 2119423 | | 2119423 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2012-11-21 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 464: | Line 613: | ||
| 621318 | | 621318 | ||
| 08/23/2011 | | 08/23/2011 | ||
− | | 08 | + | | 2011-08-23 |
| 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | | 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | ||
| Administrative | | Administrative | ||
Line 472: | Line 621: | ||
| 621319 | | 621319 | ||
| 08/23/2011 | | 08/23/2011 | ||
− | | 08 | + | | 2011-08-23 |
| SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 480: | Line 629: | ||
| 621333 | | 621333 | ||
| 08/29/2011 | | 08/29/2011 | ||
− | | | + | | 2011-08-29 |
| 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | | 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | ||
| Administrative | | Administrative | ||
Line 488: | Line 637: | ||
| 621334 | | 621334 | ||
| 08/29/2011 | | 08/29/2011 | ||
− | | | + | | 2011-08-29 |
| SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 512: | Line 661: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-115-20594 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.688636,"lon":-75.922086,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Springville Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 147743 | |
Farm/Lease Name: AUGUSTINE 3 | |
License Status: Active | |
Spud Date: 2011-08-01 | |
Permit Date: 2011-06-17 | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Latitude: 41.688636 | |
Longitude: -75.922086 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-10-29 | 2012-10-29 | 5652.00 | 105840.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Sand, White, 40/70 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 1.00 | 0.04 | |
Alpha 1427 | Baker Hughes | Biocide | Didecyl dimethyl ammonium chloride | 7173-51-5 | 0.10 | 0.00002000 | ||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 0.05 | 0.00001000 | |||||
Glutaraldehyde | 111-30-8 | 0.30 | 0.00007000 | |||||
Ethanol | 64-17-5 | 0.05 | 0.00001000 | |||||
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Calcium chloride | 10043-52-4 | 0.05 | 0.00001000 | ||
Ethylene glycol | 107-21-1 | 0.30 | 0.00008000 | |||||
Water | Operator | Carrier | Water | 7732-18-5 | 1.00 | 0.90 | ||
Superset-W | Baker Hughes | Activator | Methanol | 67-56-1 | 0.50 | 0.00085000 | ||
Nonyl phenol ethoxylate | 9016-45-9 | 0.50 | 0.00085000 | |||||
Super LC, 30/50 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 0.97 | 0.04 | ||
Phenolic resin | 9003-35-4 | 0.05 | 0.00249000 | |||||
Methenamine | 100-97-0 | 0.00010000 | 0.00 | |||||
FRW-18 | Baker Hughes | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 0.30 | 0.00019000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CABOT OIL & GAS CORP | 4,177.68 | 16 | 0.00 | 0 | 0.00 | 0 |
2013 | CABOT OIL & GAS CORP | 21,430.56 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 16,317.71 | 318 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 7,671.72 | 230 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 9,666.76 | 359 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 6,140.13 | 309 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 2,302.00 | 121 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 2,077.00 | 66 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2011-S02 | Drill Cuttings (in Tons) | 5.69 Tons | LANDFILL | 100081 |
2011-S02 | Drill Cuttings (in Tons) | 194.32 Tons | LANDFILL | 101247 |
2011-S02 | Drill Cuttings (in Tons) | 7.47 Tons | LANDFILL | 101534 |
2011-S02 | Drill Cuttings (in Tons) | 3,320.09 Tons | LANDFILL | THR029 |
2011-S02 | Drilling Fluid Waste (in Barrels) | 4,722.57 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-S02 | Basic Sediment (in Barrels) | 0.74 Bbl | LANDFILL | THR029 |
2012-S02 | Drill Cuttings (in Tons) | 124.76 Tons | LANDFILL | 301626 |
2012-S02 | Drilling Fluid Waste (in Barrels) | 717.17 Bbl | LANDFILL | THR029 |
2012-S02 | Fracing Fluid Waste (in Barrels) | 1,986.67 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE001 |
2012-S02 | Fracing Fluid Waste (in Barrels) | 7,345.37 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-S02 | Fracturing Fluid Waste (in Tons) | 12.16 Tons | LANDFILL | THR029 |
2012-S02 | Produced Fluid (in Barrels) | 79.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S01 | Produced Fluid (in Barrels) | 54.64 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE002 |
2013-S02 | Produced Fluid (in Barrels) | 188.76 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014-S01 | Produced Fluid (in Barrels) | 165.76 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014-S02 | Produced Fluid (in Barrels) | 9.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015-S01 | Produced Fluid (in Barrels) | 17.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016-S02 | Synthetic Liner Materials (in Tons) RWC 806 | 0.64 Tons | LANDFILL | 101247 |
2017-M05 | Waste Water Treatment Sludge (in Tons) RWC 804 | 4.78 Tons | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 5.60 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 2.27 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M06 | Waste Water Treatment Sludge (in Tons) RWC 804 | 0.72 Tons | REUSE (AT WELL PAD) | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 11.95 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 0.39 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 187.45 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 0.85 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1990340 | Primary Facility | 2011-07-22 | Routine/Complete Inspection | No Violations Noted | |
2000375 | Primary Facility | 2011-08-25 | Drilling/Alteration | No Violations Noted | Patterson 252. Company Man not available. 13 3/8" cemented with 460 sks with 25 bbl returns. Set at 585'. Floats held. Secondary containment in place and in good condition. |
2005264 | Primary Facility | 2011-09-21 | Drilling/Alteration | No Violations Noted | Follow up on status of well. Operator had taken excessive gas kick and have been in process of pluggin off gas so they can kick off and drill out. Drill pipe is free @3940'. Well is currently dead with 17.1 mud weight. Coil tubing unit ran out of diesel and uncoiled. At time of inspection trying to get tubing out of hole. Coil tubing unit on site to displace water in drill pipe with 17.1 mud. |
2007054 | Primary Facility | 2011-08-23 | Routine/Complete Inspection | Violation(s) Noted | |
2007193 | Primary Facility | 2011-09-27 | Drilling/Alteration | No Violations Noted | Patterson 252. Have cement plug set. Top of plug at 3350'. Currently no gas present above plug. Bottom of pipe at 3935'. Have 16.6 wt mud in hole and are slowly reduing mud wt at .10 lb at a time ciculating 5 bottoms up each interval. |
2007204 | Primary Facility | 2011-08-29 | Routine/Complete Inspection | Violation(s) Noted | |
2007235 | Primary Facility | 2011-08-25 | Routine/Complete Inspection | No Violations Noted | |
2009267 | Primary Facility | 2011-10-03 | Drilling/Alteration | No Violations Noted | Patterson 252. Flaring at time of inspection. Currently circulating 4 bottoms up at .10 ppg mud weight intervals. Currently at 13.7 ppg. Goal is to bring mud wt down to water weight equivalent while working gas up out of the hole. Drill pipe bottom is at 3300' (50 ' off bottom). Will continue to circulate for several days. |
2012667 | Primary Facility | 2011-10-19 | Drilling/Alteration | No Violations Noted | DEP on site 11:30. Patterson 252. Currently at 11.8 mud wt. Previously weighted down to water wt.and still had minimal amount of gas. At time of inspection rig broke down. Will be going back in hole to tag TOC. Eventually will be running 7" casing to fracture zone @5600' and produce through 7". DEP off site at 12:25. |
2119423 | Primary Facility | 2012-11-21 | Routine/Complete Inspection | No Violations Noted | |
2542988 | Primary Facility | 2016-12-08 | Site Restoration | No Violations Noted | |
2743170 | Primary Facility | 2018-06-18 | Routine/Complete Inspection | No Violations Noted | This well is in production. Personnel were applying temporary stabilization BMPs to the disturbed areas during the inspection. There were no violations noted. If you have any questions, please contact me. |
2757357 | Primary Facility | 2018-07-11 | Drilling/Alteration | No Violations Noted | At time of inspection arrived on location at 15:30. (4) new 20" conductors, 16" mouse-holes and CellarTech units have been set on pad. Liner and drilling mats have been placed on location in preparation for future drilling activities. (4) new annular vent tanks have been placed at edge of pad with annular vents plumbed from cellars to tanks for all (4) new wells on pad.
- There are also (2) existing wells on pad, the 3H and 4H. Both these wells have been temporarily shut in with night caps installed. Both wells had (2) annular vents, the (13 3/8"x 9 5/8") and (9 5/8"x 5 1/2") vents plumbed to individual vent tanks for each well. Gas checks performed at vent tank openings showed: Tank #1 = 100% LEL, 60% CH4; Tank #2 = 100% LEL, 7% CH4. Well heads were covered with protective steel plates limiting access at time of inspection. No markings were noted on these wells vent tanks to indicate which well was which. Gas checks performed 3' away from vent tanks showed 0% LEL, 0% CH4. Since no health and safety concer |
2758427 | Primary Facility | 2018-07-24 | Drilling/Alteration | No Violations Noted | I arrived at the site at 12:49. The weather conditions are cloudy skies, breezy and humid with rain showers and temperatures in the low to mid 70's as I arrived to the site. The rain had stopped shortly after I arrived. Precision Drilling Rig Super Single # 181 is on the location. The current drilling depth is (666) feet. I met with Will Dean, site company man, consultant of Cabot Oil and Gas and Frank Estes of Cabot Oil and Gas out of the Pittsburgh Office. Mr. Dean provided me with the following details in reference to site activities. "The rig mobilized to the site on July 19th. We are currently drilling the 9H well. The surface casing section of this well will be cemented between (720-800) feet. Thus far, the surface casing on the 11H and 13H wells has been cemented. The next well to be drilled with the surface casing cemented will be the 5H. The 3H and 4H were in production, but are currently shut in. The production fluid storage tanks have been removed from the location. Nabors Rig X 36 will dr |
2807103 | Primary Facility | 2018-10-16 | Routine/Complete Inspection | No Violations Noted | Jon Sassi (EPS) and I arrived on site at 1304 to conduct a FUI inspection on behalf of the Department.
Upon our arrival, we spoke with Brian Kudrick (EHS Consultant - Cabot) who directed us to the location of the release and accompanied us until his colleagues arrived. Roughly 10 minutes after beginning our inspection Steve Watson, Brody Webster, and Steve Catalfamo (all of whom were representing Cabot) arrived on site. During our discussion with Cabot, they informed us that the liner used for drilling and well stimulation operations is 40 mil thickness layered in a felt-liner-felt arrangement as seen in photo #4. They informed us that Cabot's SOP is to inspect the liner between drilling and fracing and make any repairs as needed. They then remove any contaminants and lay it back down if it is deemed suitable for reuse. According to the aforementioned Cabot representatives we spoke with on site, 2 roll off dumpsters of material have been excavated so far containing 30 yards each. According to Cabot, the s |
2808691 | Primary Facility | 2018-11-21 | Incident- Response to Accident or Event | No Violations Noted | I arrived at the site at 11:05 in response to a reported spill incident of (10) gallons of diesel fuel. The weather conditions are cloudy skies, breezy and chilly with snow flurries, and temperatures in the low 30's. Steve Watson, Environmental Health and Safety Specialist, and Herb Swiney, completions consultant, both of Cabot Oil and Gas were at the site during the inspection. Keane is the Cabot subcontractor at the site conducting hydraulic fracturing (stimulation) operations for the B Augustine 5H, 9H, 11H and 13H wells. Cabot submitted stimulation notices to the Department on 10/24/18. The comments in the notices indicate that frac operations would begin at 8 AM on 10/25/18. Frac operations are temporarily suspended today, 11/21/18, due to the Thanksgiving holiday according to Mr. Watson. Operations will resume on 11/23/18, Mr. Watson indicated. The 3H and 4H wells are the existing wells on the pad. These wells are currently shut in. The production equipment associated with these wells has been |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2007054 | 621318 | 08/23/2011 | 2011-08-23 | 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | Administrative | 402 |
2007054 | 621319 | 08/23/2011 | 2011-08-23 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | 6018.610 |
2007204 | 621333 | 08/29/2011 | 2011-08-29 | 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | Administrative | 402 |
2007204 | 621334 | 08/29/2011 | 2011-08-29 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | 6018.610 |
For data sources see[7]