X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-125-24386"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-125-24386
 
| Well ID: 37-125-24386
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.019622, -80.268839 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.019622, -80.268839 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 11/16/2011
+
| Spud Date: 2011-11-16
 
|-
 
|-
| Permit Date: 2/28/2011
+
| Permit Date: 2011-02-28
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2012-05-13
 +
| 2012-05-13
 +
| style="text-align: right;" | 7833.00
 +
| style="text-align: right;" | 4,873,258.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="24"| 1
 +
| rowspan="2"| DWP-944
 +
| rowspan="2"| Calfrac Well Services
 +
| rowspan="2"| Biocide
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.00190000
 +
| style="text-align: right;" |
 +
|-
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00569000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Carrier
 +
| Water
 +
|
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 94.53
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| DWP-204 Clay Control
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Buffer
 +
| Formic acid
 +
| 64-18-6
 +
| style="text-align: right;" | 13.00
 +
| style="text-align: right;" | 0.00148000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| DWP-901
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Gel Breaker
 +
| Peroxydisulfuric acid, diammonium salt
 +
| 7727-54-0
 +
| style="text-align: right;" | 95.00
 +
| style="text-align: right;" | 0.00059000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| DWP-612
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Friction Reduction
 +
| Long Chain Polyacrylamide
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.12
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="7"| DAP-925
 +
| rowspan="7"| Calfrac Well Services
 +
| rowspan="7"| Corrosion Inhibitor
 +
| Polyoxyalkylenes
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00016000
 +
| style="text-align: right;" |
 +
|-
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Thiourea polymer
 +
| 68527-49-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00016000
 +
| style="text-align: right;" |
 +
|-
 +
| Fatty Acids
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00016000
 +
| style="text-align: right;" |
 +
|-
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00033000
 +
| style="text-align: right;" |
 +
|-
 +
| Olefin
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00003000
 +
| style="text-align: right;" |
 +
|-
 +
| Propargyl alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00005000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Hydrochloric Acid
 +
| rowspan="2"| Calfrac Well Services
 +
| rowspan="2"| Acid
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.67
 +
| style="text-align: right;" |
 +
|-
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.28
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| DWP-690
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Friction Reducer Breaker
 +
| Hydrogen peroxide
 +
| 7722-84-1
 +
| style="text-align: right;" | 7.00
 +
| style="text-align: right;" | 0.00071000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="6"| DAP-901
 +
| rowspan="6"| Calfrac Well Services
 +
| rowspan="6"| Scale Inhibitor
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00420000
 +
| style="text-align: right;" |
 +
|-
 +
| Organic Phosphonate
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00420000
 +
| style="text-align: right;" |
 +
|-
 +
| Phosphoric Acid Ammonium Salt
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00070000
 +
| style="text-align: right;" |
 +
|-
 +
| Amine Salt
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00070000
 +
| style="text-align: right;" |
 +
|-
 +
| Ammonium chloride
 +
| 12125-02-9
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00140000
 +
| style="text-align: right;" |
 +
|-
 +
| Oxyalkylated Polyamine
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00070000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Proppant
 +
| Sand
 +
|
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 4.27
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| DWP-111
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Viscosity Additive
 +
| Polysaccharide Suspension
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.05
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 156: Line 381:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 15AUGU
+
| 2012-S01
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 110.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15DECU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 77.50 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15JULU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 170.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15NOVU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 110.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15OCTU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 55.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15SEPU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 133.75 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16APRU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16AUGU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 110.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16DECU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 138.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16FEBU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 82.50 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16JANU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16JULU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 83.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16JUNU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 67.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-013-20609
 
|-
 
| 16MARU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 110.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16MAYU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16NOVU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 28.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 45.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-013-20609
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 23.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28803
 
|-
 
| 16SEPU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 30.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2012-1
 
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 115.60 Tons
 
| style="text-align: right;" | 115.60 Tons
Line 276: Line 387:
 
| 0250050885
 
| 0250050885
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 831.17 Tons
 
| style="text-align: right;" | 831.17 Tons
Line 282: Line 393:
 
| 100172
 
| 100172
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 280.13 Tons
 
| style="text-align: right;" | 280.13 Tons
Line 288: Line 399:
 
| 100277
 
| 100277
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 1,232.32 Bbl
 
| style="text-align: right;" | 1,232.32 Bbl
Line 294: Line 405:
 
| 0250050885
 
| 0250050885
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 3,632.00 Bbl
 
| style="text-align: right;" | 3,632.00 Bbl
Line 300: Line 411:
 
|  
 
|  
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 3,008.33 Bbl
 
| style="text-align: right;" | 3,008.33 Bbl
Line 306: Line 417:
 
|  
 
|  
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 831.28 Bbl
 
| style="text-align: right;" | 831.28 Bbl
Line 312: Line 423:
 
|  
 
|  
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 18.58 Bbl
 
| style="text-align: right;" | 18.58 Bbl
Line 318: Line 429:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 13.22 Bbl
 
| style="text-align: right;" | 13.22 Bbl
Line 324: Line 435:
 
| 34-031-27177
 
| 34-031-27177
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 7.24 Bbl
 
| style="text-align: right;" | 7.24 Bbl
Line 330: Line 441:
 
| 34-059-24202
 
| 34-059-24202
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 51.73 Bbl
 
| style="text-align: right;" | 51.73 Bbl
Line 336: Line 447:
 
| 34-105-23619
 
| 34-105-23619
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 0.69 Bbl
 
| style="text-align: right;" | 0.69 Bbl
Line 342: Line 453:
 
| 34-119-28776
 
| 34-119-28776
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 646.09 Bbl
 
| style="text-align: right;" | 646.09 Bbl
Line 348: Line 459:
 
|  
 
|  
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 6.41 Bbl
 
| style="text-align: right;" | 6.41 Bbl
Line 354: Line 465:
 
| 2D0859721
 
| 2D0859721
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 29.49 Bbl
 
| style="text-align: right;" | 29.49 Bbl
Line 360: Line 471:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 24.36 Bbl
 
| style="text-align: right;" | 24.36 Bbl
Line 366: Line 477:
 
| 34-059-24202
 
| 34-059-24202
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 6.41 Bbl
 
| style="text-align: right;" | 6.41 Bbl
Line 372: Line 483:
 
| 34-119-28776
 
| 34-119-28776
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 7.69 Bbl
 
| style="text-align: right;" | 7.69 Bbl
Line 378: Line 489:
 
| 34-121-23995
 
| 34-121-23995
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 569.76 Bbl
 
| style="text-align: right;" | 569.76 Bbl
Line 384: Line 495:
 
|  
 
|  
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 53.86 Bbl
 
| style="text-align: right;" | 53.86 Bbl
Line 390: Line 501:
 
|  
 
|  
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 601.00 Bbl
 
| style="text-align: right;" | 601.00 Bbl
Line 396: Line 507:
 
|  
 
|  
 
|-
 
|-
| 2015-07
+
| 2015-M07
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 170.00 Bbl
 
| style="text-align: right;" | 170.00 Bbl
Line 402: Line 513:
 
|  
 
|  
 
|-
 
|-
| 2015-08
+
| 2015-M08
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 110.00 Bbl
 
| style="text-align: right;" | 110.00 Bbl
Line 408: Line 519:
 
|  
 
|  
 
|-
 
|-
| 2015-09
+
| 2015-M09
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 133.75 Bbl
 
| style="text-align: right;" | 133.75 Bbl
Line 414: Line 525:
 
|  
 
|  
 
|-
 
|-
| 2015-1
+
| 2015-M10
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 558.94 Bbl
+
| style="text-align: right;" | 55.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-10
+
| 2015-M11
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 55.00 Bbl
+
| style="text-align: right;" | 110.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-11
+
| 2015-M12
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 110.00 Bbl
+
| style="text-align: right;" | 77.50 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-12
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 77.50 Bbl
+
| style="text-align: right;" | 558.94 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2016-01
+
| 2016-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 444: Line 555:
 
|  
 
|  
 
|-
 
|-
| 2016-02
+
| 2016-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 82.50 Bbl
 
| style="text-align: right;" | 82.50 Bbl
Line 450: Line 561:
 
|  
 
|  
 
|-
 
|-
| 2016-03
+
| 2016-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 110.00 Bbl
 
| style="text-align: right;" | 110.00 Bbl
Line 456: Line 567:
 
|  
 
|  
 
|-
 
|-
| 2016-04
+
| 2016-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 462: Line 573:
 
|  
 
|  
 
|-
 
|-
| 2016-05
+
| 2016-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 468: Line 579:
 
|  
 
|  
 
|-
 
|-
| 2016-06
+
| 2016-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 67.50 Bbl
 
| style="text-align: right;" | 67.50 Bbl
Line 474: Line 585:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2016-07
+
| 2016-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 83.00 Bbl
 
| style="text-align: right;" | 83.00 Bbl
Line 480: Line 591:
 
|  
 
|  
 
|-
 
|-
| 2016-08
+
| 2016-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 110.00 Bbl
 
| style="text-align: right;" | 110.00 Bbl
Line 486: Line 597:
 
|  
 
|  
 
|-
 
|-
| 2016-09
+
| 2016-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 30.00 Bbl
 
| style="text-align: right;" | 30.00 Bbl
Line 492: Line 603:
 
|  
 
|  
 
|-
 
|-
| 2016-10
+
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 45.00 Bbl
 
| style="text-align: right;" | 45.00 Bbl
Line 498: Line 609:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2016-10
+
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 23.00 Bbl
 
| style="text-align: right;" | 23.00 Bbl
Line 504: Line 615:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2016-11
+
| 2016-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 28.00 Bbl
 
| style="text-align: right;" | 28.00 Bbl
Line 510: Line 621:
 
|  
 
|  
 
|-
 
|-
| 2016-12
+
| 2016-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 138.00 Bbl
 
| style="text-align: right;" | 138.00 Bbl
Line 516: Line 627:
 
|  
 
|  
 
|-
 
|-
| 2017-01
+
| 2017-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 82.50 Bbl
 
| style="text-align: right;" | 82.50 Bbl
Line 522: Line 633:
 
| 95-7-37312-10
 
| 95-7-37312-10
 
|-
 
|-
| 2017-01
+
| 2017-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 528: Line 639:
 
| 95-7-37312-32
 
| 95-7-37312-32
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 53.50 Bbl
 
| style="text-align: right;" | 53.50 Bbl
Line 534: Line 645:
 
| 95-7-37312-21
 
| 95-7-37312-21
 
|-
 
|-
| 2017-03
+
| 2017-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 540: Line 651:
 
|  
 
|  
 
|-
 
|-
| 2017-03
+
| 2017-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 546: Line 657:
 
| 95-7-37312-16
 
| 95-7-37312-16
 
|-
 
|-
| 2017-04
+
| 2017-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 552: Line 663:
 
|  
 
|  
 
|-
 
|-
| 2017-05
+
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 92.00 Bbl
 
| style="text-align: right;" | 92.00 Bbl
Line 558: Line 669:
 
| 95-7-37312-10
 
| 95-7-37312-10
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 564: Line 675:
 
| 95-7-37312-10
 
| 95-7-37312-10
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 570: Line 681:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 30.00 Bbl
 
| style="text-align: right;" | 30.00 Bbl
Line 576: Line 687:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2017-09
+
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 22.50 Bbl
 
| style="text-align: right;" | 22.50 Bbl
Line 582: Line 693:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 588: Line 699:
 
|  
 
|  
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 594: Line 705:
 
| 95-7-37312-17
 
| 95-7-37312-17
 
|-
 
|-
| 2017-11
+
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 42.50 Bbl
 
| style="text-align: right;" | 42.50 Bbl
Line 600: Line 711:
 
| 95-7-37312-21
 
| 95-7-37312-21
 
|-
 
|-
| 2017-12
+
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 606: Line 717:
 
|  
 
|  
 
|-
 
|-
| 2017-12
+
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 612: Line 723:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 76.50 Bbl
 
| style="text-align: right;" | 76.50 Bbl
Line 618: Line 729:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2018-02
+
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 52.25 Bbl
 
| style="text-align: right;" | 52.25 Bbl
Line 624: Line 735:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2018-03
+
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 37.50 Bbl
 
| style="text-align: right;" | 37.50 Bbl
Line 630: Line 741:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2018-03
+
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 636: Line 747:
 
| 95-7-37312-21
 
| 95-7-37312-21
 
|-
 
|-
| 2018-04
+
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 2.50 Bbl
 
| style="text-align: right;" | 2.50 Bbl
Line 642: Line 753:
 
|  
 
|  
 
|-
 
|-
| 2018-04
+
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 18.75 Bbl
 
| style="text-align: right;" | 18.75 Bbl
Line 648: Line 759:
 
| ODNR 2015-29
 
| ODNR 2015-29
 
|-
 
|-
| 2018-05
+
| 2018-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 654: Line 765:
 
|  
 
|  
 
|-
 
|-
| 2018-05
+
| 2018-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 660: Line 771:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2018-06
+
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 666: Line 777:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 16.25 Bbl
 
| style="text-align: right;" | 16.25 Bbl
Line 672: Line 783:
 
|  
 
|  
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 678: Line 789:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2018-08
+
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 35.00 Bbl
 
| style="text-align: right;" | 35.00 Bbl
Line 684: Line 795:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 57.50 Bbl
 
| style="text-align: right;" | 57.50 Bbl
Line 690: Line 801:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 71.25 Bbl
 
| style="text-align: right;" | 71.25 Bbl
Line 696: Line 807:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 107.50 Bbl
 
| style="text-align: right;" | 107.50 Bbl
Line 702: Line 813:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2019-01
+
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 708: Line 819:
 
| 95-7-37312-19
 
| 95-7-37312-19
 
|-
 
|-
| 2019-03
+
| 2019-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 714: Line 825:
 
|  
 
|  
 
|-
 
|-
| 2019-03
+
| 2019-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 739: Line 850:
 
| 2035507
 
| 2035507
 
| Primary Facility
 
| Primary Facility
| 01/09/2012
+
| 2012-01-09
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 811: Line 922:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 05/13/2012
 
| 05/13/2012
 
| style="text-align: right;" | 7833.00
 
| style="text-align: right;" | 4,873,258.0
 
| style="text-align: right;" |
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="24"| 1
 
| rowspan="2"| DWP-944
 
| rowspan="2"| Calfrac Well Services
 
| rowspan="2"| Biocide
 
| 2,2-Dibromo-3-nitrilopropionamide
 
| 10222-01-2
 
| style="text-align: right;" | 20.00
 
| style="text-align: right;" | 0.00190000
 
| style="text-align: right;" |
 
|-
 
| Polyethylene glycol
 
| 25322-68-3
 
| style="text-align: right;" | 60.00
 
| style="text-align: right;" | 0.00569000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Water
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Carrier
 
| Water
 
|
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 94.53
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| DWP-204 Clay Control
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Buffer
 
| Formic acid
 
| 64-18-6
 
| style="text-align: right;" | 13.00
 
| style="text-align: right;" | 0.00148000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| DWP-901
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Gel Breaker
 
| Peroxydisulfuric acid, diammonium salt
 
| 7727-54-0
 
| style="text-align: right;" | 95.00
 
| style="text-align: right;" | 0.00059000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| DWP-612
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Friction Reduction
 
| Long Chain Polyacrylamide
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" | 0.12
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="7"| DAP-925
 
| rowspan="7"| Calfrac Well Services
 
| rowspan="7"| Corrosion Inhibitor
 
| Polyoxyalkylenes
 
|
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00016000
 
| style="text-align: right;" |
 
|-
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
| Thiourea polymer
 
| 68527-49-1
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00016000
 
| style="text-align: right;" |
 
|-
 
| Fatty Acids
 
|
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00016000
 
| style="text-align: right;" |
 
|-
 
| Methanol
 
| 67-56-1
 
| style="text-align: right;" | 60.00
 
| style="text-align: right;" | 0.00033000
 
| style="text-align: right;" |
 
|-
 
| Olefin
 
|
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00003000
 
| style="text-align: right;" |
 
|-
 
| Propargyl alcohol
 
| 107-19-7
 
| style="text-align: right;" | 10.00
 
| style="text-align: right;" | 0.00005000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="2"| Hydrochloric Acid
 
| rowspan="2"| Calfrac Well Services
 
| rowspan="2"| Acid
 
| Hydrochloric acid
 
| 7647-01-0
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.67
 
| style="text-align: right;" |
 
|-
 
| Hydrochloric acid
 
| 7647-01-0
 
| style="text-align: right;" | 15.00
 
| style="text-align: right;" | 0.28
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| DWP-690
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Friction Reducer Breaker
 
| Hydrogen peroxide
 
| 7722-84-1
 
| style="text-align: right;" | 7.00
 
| style="text-align: right;" | 0.00071000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="6"| DAP-901
 
| rowspan="6"| Calfrac Well Services
 
| rowspan="6"| Scale Inhibitor
 
| Methanol
 
| 67-56-1
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00420000
 
| style="text-align: right;" |
 
|-
 
| Organic Phosphonate
 
|
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00420000
 
| style="text-align: right;" |
 
|-
 
| Phosphoric Acid Ammonium Salt
 
|
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00070000
 
| style="text-align: right;" |
 
|-
 
| Amine Salt
 
|
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00070000
 
| style="text-align: right;" |
 
|-
 
| Ammonium chloride
 
| 12125-02-9
 
| style="text-align: right;" | 10.00
 
| style="text-align: right;" | 0.00140000
 
| style="text-align: right;" |
 
|-
 
| Oxyalkylated Polyamine
 
|
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00070000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Sand
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Proppant
 
| Sand
 
|
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 4.27
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| DWP-111
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Viscosity Additive
 
| Polysaccharide Suspension
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" | 0.05
 
| style="text-align: right;" |
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 11:20, 3 August 2019

Well Details

Well ID: 37-125-24386
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Morris Township
Operator Name: CNX GAS CO LLC
Well Pad ID: 148001
Farm/Lease Name: CONRHEIN NV30CHS
License Status: Active
Spud Date: 2011-11-16
Permit Date: 2011-02-28
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.019622
Longitude: -80.268839

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-05-13 2012-05-13 7833.00 4,873,258.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 DWP-944 Calfrac Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00190000
Polyethylene glycol 25322-68-3 60.00 0.00569000
Water Calfrac Well Services Carrier Water 100.00 94.53
DWP-204 Clay Control Calfrac Well Services Buffer Formic acid 64-18-6 13.00 0.00148000
DWP-901 Calfrac Well Services Gel Breaker Peroxydisulfuric acid, diammonium salt 7727-54-0 95.00 0.00059000
DWP-612 Calfrac Well Services Friction Reduction Long Chain Polyacrylamide 0.12
DAP-925 Calfrac Well Services Corrosion Inhibitor Polyoxyalkylenes 30.00 0.00016000
Thiourea polymer 68527-49-1 30.00 0.00016000
Fatty Acids 30.00 0.00016000
Methanol 67-56-1 60.00 0.00033000
Olefin 5.00 0.00003000
Propargyl alcohol 107-19-7 10.00 0.00005000
Hydrochloric Acid Calfrac Well Services Acid Hydrochloric acid 7647-01-0 5.00 0.67
Hydrochloric acid 7647-01-0 15.00 0.28
DWP-690 Calfrac Well Services Friction Reducer Breaker Hydrogen peroxide 7722-84-1 7.00 0.00071000
DAP-901 Calfrac Well Services Scale Inhibitor Methanol 67-56-1 30.00 0.00420000
Organic Phosphonate 30.00 0.00420000
Phosphoric Acid Ammonium Salt 5.00 0.00070000
Amine Salt 5.00 0.00070000
Ammonium chloride 12125-02-9 10.00 0.00140000
Oxyalkylated Polyamine 5.00 0.00070000
Sand Calfrac Well Services Proppant Sand 100.00 4.27
DWP-111 Calfrac Well Services Viscosity Additive Polysaccharide Suspension 0.05

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2012 CNX GAS CO LLC 659,786.75 218 0.00 0 0.00 0
2013 CNX GAS CO LLC 529,741.63 365 0.00 0 0.00 0
2014 CNX GAS CO LLC 615,320.54 365 0.00 0 0.00 0
2015 CNX GAS CO LLC 479,159.58 365 0.00 0 0.00 0
2016 CNX GAS CO LLC 387,936.67 366 0.00 0 0.00 0
2017 CNX GAS CO LLC 322,159.55 365 0.00 0 0.00 0
2018 CNX GAS CO LLC 274,916.78 365 0.00 0 0.00 0
2019 CNX GAS CO LLC 61,655.69 89 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-S01 Drill Cuttings (in Tons) 115.60 Tons LANDFILL 0250050885
2012-S01 Drill Cuttings (in Tons) 831.17 Tons LANDFILL 100172
2012-S01 Drill Cuttings (in Tons) 280.13 Tons LANDFILL 100277
2012-S01 Drilling Fluid Waste (in Barrels) 1,232.32 Bbl LANDFILL 0250050885
2012-S01 Fracing Fluid Waste (in Barrels) 3,632.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S01 Produced Fluid (in Barrels) 3,008.33 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Produced Fluid (in Barrels) 831.28 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Produced Fluid (in Barrels) 18.58 Bbl INJECTION DISPOSAL WELL 34-013-20609
2013-S02 Produced Fluid (in Barrels) 13.22 Bbl INJECTION DISPOSAL WELL 34-031-27177
2013-S02 Produced Fluid (in Barrels) 7.24 Bbl INJECTION DISPOSAL WELL 34-059-24202
2013-S02 Produced Fluid (in Barrels) 51.73 Bbl INJECTION DISPOSAL WELL 34-105-23619
2013-S02 Produced Fluid (in Barrels) 0.69 Bbl INJECTION DISPOSAL WELL 34-119-28776
2013-S02 Produced Fluid (in Barrels) 646.09 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Produced Fluid (in Barrels) 6.41 Bbl INJECTION DISPOSAL WELL 2D0859721
2014-S01 Produced Fluid (in Barrels) 29.49 Bbl INJECTION DISPOSAL WELL 34-013-20609
2014-S01 Produced Fluid (in Barrels) 24.36 Bbl INJECTION DISPOSAL WELL 34-059-24202
2014-S01 Produced Fluid (in Barrels) 6.41 Bbl INJECTION DISPOSAL WELL 34-119-28776
2014-S01 Produced Fluid (in Barrels) 7.69 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014-S01 Produced Fluid (in Barrels) 569.76 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Produced Fluid (in Barrels) 53.86 Bbl STORAGE PENDING DISPOSAL OR REUSE
2014-S02 Produced Fluid (in Barrels) 601.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M07 Produced Fluid (in Barrels) 170.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M08 Produced Fluid (in Barrels) 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M09 Produced Fluid (in Barrels) 133.75 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M10 Produced Fluid (in Barrels) 55.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M11 Produced Fluid (in Barrels) 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M12 Produced Fluid (in Barrels) 77.50 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 558.94 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M01 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M02 Produced Fluid (in Barrels) RWC 802 82.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M03 Produced Fluid (in Barrels) RWC 802 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M04 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M05 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M06 Produced Fluid (in Barrels) RWC 802 67.50 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-M07 Produced Fluid (in Barrels) RWC 802 83.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M08 Produced Fluid (in Barrels) RWC 802 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M09 Produced Fluid (in Barrels) RWC 802 30.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M10 Produced Fluid (in Barrels) RWC 802 45.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-M10 Produced Fluid (in Barrels) RWC 802 23.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-M11 Produced Fluid (in Barrels) RWC 802 28.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M12 Produced Fluid (in Barrels) RWC 802 138.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 82.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-10
2017-M01 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-32
2017-M02 Produced Fluid (in Barrels) RWC 802 53.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2017-M03 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2017-M03 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-16
2017-M04 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 92.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-10
2017-M06 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-10
2017-M07 Produced Fluid (in Barrels) RWC 802 55.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2017-M08 Produced Fluid (in Barrels) RWC 802 30.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-M09 Produced Fluid (in Barrels) RWC 802 22.50 Bbl INJECTION DISPOSAL WELL 34-013-20609
2017-M10 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-17
2017-M11 Produced Fluid (in Barrels) RWC 802 42.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2017-M12 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2017-M12 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-M01 Produced Fluid (in Barrels) RWC 802 76.50 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-M02 Produced Fluid (in Barrels) RWC 802 52.25 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-M03 Produced Fluid (in Barrels) RWC 802 37.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-M03 Produced Fluid (in Barrels) RWC 802 55.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2018-M04 Produced Fluid (in Barrels) RWC 802 2.50 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018-M04 Produced Fluid (in Barrels) RWC 802 18.75 Bbl RESIDUAL WASTE PROCESSING FACILITY ODNR 2015-29
2018-M05 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-M06 Produced Fluid (in Barrels) RWC 802 55.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-M07 Produced Fluid (in Barrels) RWC 802 16.25 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-M08 Produced Fluid (in Barrels) RWC 802 35.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-M09 Produced Fluid (in Barrels) RWC 802 57.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-M10 Produced Fluid (in Barrels) RWC 802 71.25 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-M12 Produced Fluid (in Barrels) RWC 802 107.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019-M01 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019-M03 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-7-37312-19

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2035507 Primary Facility 2012-01-09 Drilling/Alteration No Violations Noted Well drilled to KOP at 6600ft. Location is in good condition.
2630833 Primary Facility 2017-08-16 Routine/Complete Inspection No Violations Noted On Wednesday, August 16, 2017, I conducted a routine-complete inspection at the NV 30 Well Site located in Morris Township, Green County.

The Act 9 sign was in place and clearly legible t the site entrance. All required documentation was available on-site, although the physical integrity of the documents is deteriorating. The operator should consider periodically checking the documentation on each well site to assure the materials are up to date and legible.

The access road and the well pad were in good condition and the site is stabilized with vegetative growth.

The secondary containment structure around the production tanks appeared to be in good condition and functioning as intended. The gas wells and associated GPUs appeared to be in good working order and each well is labelled as required.

No violations were identified during the inspection.

2679127 Primary Facility 2018-01-08 Routine/Complete Inspection No Violations Noted On Friday, January 5, 2018, I conducted a routine-complete inspection at the NV 30 Well Site located in Morris Township, Washington County.

The gas well NV30CHS (125-24386) appeared to be in good working order and was labelled.

No violations were identified during the inspection.

2825110 Primary Facility 2019-01-08 Routine/Complete Inspection No Violations Noted On Tuesday January 8, 2019 I conducted a routine-complete inspection at the NV30 Well Site in Morris Township, Washington County.

The gas well and the associated infrastructure appeared to be in good condition and functioning properly. The well was tagged with identification.

No violations were identified during the inspection.

For data sources see[7]

References