If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-007-20396 | | Well ID: 37-007-20396 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 40.739631, -80.1691 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 09 | + | | Spud Date: 2013-09-11 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2013-07-08 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2014-02-19 | ||
+ | | 2014-03-01 | ||
+ | | style="text-align: right;" | 5140 | ||
+ | | style="text-align: right;" | 13,270,000.0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="19"| 1 | ||
+ | | rowspan="3"| EC6116A | ||
+ | | rowspan="3"| Nalco | ||
+ | | rowspan="3"| Biocide | ||
+ | | Polyethylene Glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00667149 | ||
+ | | style="text-align: right;" | 8481.36 | ||
+ | |- | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.000555958 | ||
+ | | style="text-align: right;" | 706.78 | ||
+ | |- | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00333575 | ||
+ | | style="text-align: right;" | 4240.68 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Hydrochloric Acid (7.5%) | ||
+ | | rowspan="1"| Axiall | ||
+ | | rowspan="1"| Acidizing | ||
+ | | Hydrogen Chloride | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 1.1709 | ||
+ | | style="text-align: right;" | 1,488,540.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Scale Hib A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00329451 | ||
+ | | style="text-align: right;" | 4188.26 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand (Proppant) | ||
+ | | rowspan="1"| Sargent | ||
+ | | rowspan="1"| Proppant | ||
+ | | Silica | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 99.9 | ||
+ | | style="text-align: right;" | 9.83669 | ||
+ | | style="text-align: right;" | 12,505,200.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| I-7L | ||
+ | | rowspan="3"| Weatherford | ||
+ | | rowspan="3"| Iron Control | ||
+ | | Triethanolamine Hydroxyacetate | ||
+ | | 68299-02-5 | ||
+ | | style="text-align: right;" | 20 | ||
+ | | style="text-align: right;" | 0.00212445 | ||
+ | | style="text-align: right;" | 2700.78 | ||
+ | |- | ||
+ | | Glycolic Acid | ||
+ | | 79-14-1 | ||
+ | | style="text-align: right;" | 2.5 | ||
+ | | style="text-align: right;" | 0.000265556 | ||
+ | | style="text-align: right;" | 337.597 | ||
+ | |- | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 20 | ||
+ | | style="text-align: right;" | 0.00212445 | ||
+ | | style="text-align: right;" | 2700.78 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| WGA-3 | ||
+ | | rowspan="1"| PfP Technology | ||
+ | | rowspan="1"| Water Viscosifier | ||
+ | | Guar Gum | ||
+ | | 9000-30-0 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00125857 | ||
+ | | style="text-align: right;" | 1600 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| PennEnergy Resources | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 87.1076 | ||
+ | | style="text-align: right;" | 110,738,000.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Unislik ST50 | ||
+ | | rowspan="1"| CESI | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Petroleum Distillates, Hydrotreated Light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0253226 | ||
+ | | style="text-align: right;" | 32192.2 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| LEB 10X | ||
+ | | rowspan="1"| Weatherford | ||
+ | | rowspan="1"| Gel Breaker | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.00001217 | ||
+ | | style="text-align: right;" | 15.475 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="6"| Unihib G | ||
+ | | rowspan="6"| GeoSafe | ||
+ | | rowspan="6"| Acid Corrosion Inhibitor | ||
+ | | Acetophenone | ||
+ | | 98-86-2 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000189 | ||
+ | | style="text-align: right;" | 2.406 | ||
+ | |- | ||
+ | | Thiourea | ||
+ | | 62-56-6 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000189 | ||
+ | | style="text-align: right;" | 2.406 | ||
+ | |- | ||
+ | | Glycol Ether | ||
+ | | 112-34-5 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.000113548 | ||
+ | | style="text-align: right;" | 144.352 | ||
+ | |- | ||
+ | | Ethoxylated Alcohol | ||
+ | | 68002-97-1 | ||
+ | | style="text-align: right;" | 35 | ||
+ | | style="text-align: right;" | 0.00006624 | ||
+ | | style="text-align: right;" | 84.205 | ||
+ | |- | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00000946 | ||
+ | | style="text-align: right;" | 12.029 | ||
+ | |- | ||
+ | | Formaldehyde | ||
+ | | 50-00-0 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000189 | ||
+ | | style="text-align: right;" | 2.406 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 133: | Line 324: | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Period | !scope="col" | Period | ||
+ | !scope="col" | Operator | ||
!scope="col" | Waste Type | !scope="col" | Waste Type | ||
!scope="col" | Quantity | !scope="col" | Quantity | ||
Line 138: | Line 330: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2013 | + | | 2013 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 3,835.00 Bbl | | style="text-align: right;" | 3,835.00 Bbl | ||
Line 150: | Line 337: | ||
| EPA ID: 748-163 | | EPA ID: 748-163 | ||
|- | |- | ||
− | | | + | | 2013 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 752.00 Tons |
| LANDFILL | | LANDFILL | ||
| CID # 28726 | | CID # 28726 | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 47.30 Tons | | style="text-align: right;" | 47.30 Tons | ||
Line 162: | Line 351: | ||
| CID # 28726 | | CID # 28726 | ||
|- | |- | ||
− | | 2015 | + | | 2014 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
+ | | Drill Cuttings (in Tons) | ||
+ | | style="text-align: right;" | 25.75 Tons | ||
+ | | LANDFILL | ||
+ | | CID # 28726 | ||
+ | |- | ||
+ | | 2015 | ||
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Servicing Fluid (in Barrels) | | Servicing Fluid (in Barrels) | ||
| style="text-align: right;" | 21.00 Bbl | | style="text-align: right;" | 21.00 Bbl | ||
Line 168: | Line 365: | ||
| CID # 28726 | | CID # 28726 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 72.40 Bbl | | style="text-align: right;" | 72.40 Bbl | ||
Line 180: | Line 372: | ||
| EPA ID: 748-163 | | EPA ID: 748-163 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 428.81 Bbl | | style="text-align: right;" | 428.81 Bbl | ||
Line 192: | Line 379: | ||
| 34-155-23196 | | 34-155-23196 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[PENNENERGY RESOURCES LLC]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 4,471.89 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | | + | | 2016 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,225.79 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
− | | | + | | 34-155-22403 |
|- | |- | ||
− | | | + | | 2016 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 483.10 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
− | | | + | | 34-155-23223 |
|- | |- | ||
− | | 2017 | + | | 2017 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 3,302.13 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | | + | | 2018 |
+ | | [[PENNENERGY RESOURCES LLC]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,660.73 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[PENNENERGY RESOURCES LLC]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 567.87 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
Line 385: | Line 440: | ||
| 2201875 | | 2201875 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2013-09-05 |
| Administrative/File Review | | Administrative/File Review | ||
| No Violations Noted | | No Violations Noted | ||
Line 392: | Line 447: | ||
| 2205409 | | 2205409 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2013-09-18 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 399: | Line 454: | ||
| 2206056 | | 2206056 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2013-09-11 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 406: | Line 461: | ||
| 2206058 | | 2206058 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2013-09-18 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 413: | Line 468: | ||
| 2212252 | | 2212252 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2013-10-08 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 420: | Line 475: | ||
| 2213881 | | 2213881 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2013-10-16 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 427: | Line 482: | ||
| 2223187 | | 2223187 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2013-11-14 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 434: | Line 489: | ||
| 2227170 | | 2227170 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2013-11-25 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 441: | Line 496: | ||
| 2227173 | | 2227173 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2013-12-05 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 448: | Line 503: | ||
| 2231780 | | 2231780 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2013-12-11 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 455: | Line 510: | ||
| 2232278 | | 2232278 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2013-10-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 462: | Line 517: | ||
| 2232813 | | 2232813 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2013-11-05 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 469: | Line 524: | ||
| 2232823 | | 2232823 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2013-11-12 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 476: | Line 531: | ||
| 2236882 | | 2236882 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2014-01-13 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 483: | Line 538: | ||
| 2247357 | | 2247357 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2014-01-02 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 490: | Line 545: | ||
| 2247360 | | 2247360 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2014-01-14 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 497: | Line 552: | ||
| 2251836 | | 2251836 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2014-02-11 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 504: | Line 559: | ||
| 2255752 | | 2255752 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2014-03-17 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 511: | Line 566: | ||
| 2255756 | | 2255756 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2014-03-13 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 518: | Line 573: | ||
| 2257676 | | 2257676 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2014-03-20 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 525: | Line 580: | ||
| 2259858 | | 2259858 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-01 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 532: | Line 587: | ||
| 2275106 | | 2275106 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-07 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 539: | Line 594: | ||
| 2361477 | | 2361477 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2015-04-10 |
| Routine/Partial Inspection | | Routine/Partial Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 546: | Line 601: | ||
| 2372410 | | 2372410 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2015-04-20 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 553: | Line 608: | ||
| 2374329 | | 2374329 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2015-05-26 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 560: | Line 615: | ||
| 2391271 | | 2391271 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2015-07-17 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 567: | Line 622: | ||
| 2392557 | | 2392557 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2015-07-17 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 658: | Line 713: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-007-20396 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.739631,"lon":-80.1691,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Beaver | |
Municipality: New Sewickley Township | |
Operator Name: PENNENERGY RESOURCES LLC | |
Well Pad ID: 145356 | |
Farm/Lease Name: B1 PER B1-3HUD | |
License Status: Active | |
Spud Date: 2013-09-11 | |
Permit Date: 2013-07-08 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.739631 | |
Longitude: -80.1691 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-02-19 | 2014-03-01 | 5140 | 13,270,000.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | EC6116A | Nalco | Biocide | Polyethylene Glycol | 25322-68-3 | 60 | 0.00667149 | 8481.36 |
Dibromoacetonitrile | 3252-43-5 | 5 | 0.000555958 | 706.78 | ||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00333575 | 4240.68 | ||||
Hydrochloric Acid (7.5%) | Axiall | Acidizing | Hydrogen Chloride | 7647-01-0 | 40 | 1.1709 | 1,488,540.0 | |
Scale Hib A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00329451 | 4188.26 | |
Sand (Proppant) | Sargent | Proppant | Silica | 14808-60-7 | 99.9 | 9.83669 | 12,505,200.0 | |
I-7L | Weatherford | Iron Control | Triethanolamine Hydroxyacetate | 68299-02-5 | 20 | 0.00212445 | 2700.78 | |
Glycolic Acid | 79-14-1 | 2.5 | 0.000265556 | 337.597 | ||||
Ethylene Glycol | 107-21-1 | 20 | 0.00212445 | 2700.78 | ||||
WGA-3 | PfP Technology | Water Viscosifier | Guar Gum | 9000-30-0 | 100 | 0.00125857 | 1600 | |
Water | PennEnergy Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.1076 | 110,738,000.0 | |
Unislik ST50 | CESI | Friction Reducer | Petroleum Distillates, Hydrotreated Light | 64742-47-8 | 30 | 0.0253226 | 32192.2 | |
LEB 10X | Weatherford | Gel Breaker | Ethylene Glycol | 107-21-1 | 40 | 0.00001217 | 15.475 | |
Unihib G | GeoSafe | Acid Corrosion Inhibitor | Acetophenone | 98-86-2 | 1 | 0.00000189 | 2.406 | |
Thiourea | 62-56-6 | 1 | 0.00000189 | 2.406 | ||||
Glycol Ether | 112-34-5 | 60 | 0.000113548 | 144.352 | ||||
Ethoxylated Alcohol | 68002-97-1 | 35 | 0.00006624 | 84.205 | ||||
Methanol | 67-56-1 | 5 | 0.00000946 | 12.029 | ||||
Formaldehyde | 50-00-0 | 1 | 0.00000189 | 2.406 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | PENNENERGY RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | PENNENERGY RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | PENNENERGY RESOURCES LLC | 699,724.00 | 176 | 0.00 | 0 | 8,614.00 | 176 |
2016 | PENNENERGY RESOURCES LLC | 1,029,445.00 | 366 | 0.00 | 0 | 8,796.00 | 366 |
2017 | PENNENERGY RESOURCES LLC | 799,230.00 | 348 | 0.00 | 0 | 4,571.00 | 348 |
2018 | PENNENERGY RESOURCES LLC | 691,726.00 | 356 | 0.00 | 0 | 3,322.00 | 356 |
2019 | PENNENERGY RESOURCES LLC | 150,295.00 | 78 | 0.00 | 0 | 694.00 | 78 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste (in Barrels) | 3,835.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2013 | PENNENERGY RESOURCES LLC | Drill Cuttings (in Tons) | 752.00 Tons | LANDFILL | CID # 28726 |
2014 | PENNENERGY RESOURCES LLC | Fracturing Fluid Waste (in Tons) | 47.30 Tons | LANDFILL | CID # 28726 |
2014 | PENNENERGY RESOURCES LLC | Drill Cuttings (in Tons) | 25.75 Tons | LANDFILL | CID # 28726 |
2015 | PENNENERGY RESOURCES LLC | Servicing Fluid (in Barrels) | 21.00 Bbl | LANDFILL | CID # 28726 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 72.40 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 428.81 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 4,471.89 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 1,225.79 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 483.10 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2017 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 3,302.13 Bbl | REUSE (AT WELL PAD) | |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 1,660.73 Bbl | REUSE (AT WELL PAD) | |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid (in Barrels) RWC 802 | 567.87 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2201875 | Primary Facility | 2013-09-05 | Administrative/File Review | No Violations Noted | This preoperational inspection satisfies operator's obligation as outlined under Title 58 , Ch 32 § 3258 a. 1. |
2205409 | Primary Facility | 2013-09-18 | Routine/Complete Inspection | No Violations Noted | This well targets the Geneseo Shale formation. The conductor was set and the cellar was covered with steel plate. The inspection for this well was conducted concurrently with the inspection for site number 768793 (inspection report # 2205390.) Impoundment was without liner and under construction. No erosion or sedimentation issues were apparent. |
2206056 | Primary Facility | 2013-09-11 | Drilling/Alteration | No Violations Noted | AN AUGER RIG IS ON THE PAD TO DRILL THE CONDUCTOR. THE SITE IS OK. |
2206058 | Primary Facility | 2013-09-18 | Drilling/Alteration | No Violations Noted | CELLER AND CONDUCTOR ARE IN AND COVERED. |
2212252 | Primary Facility | 2013-10-08 | Drilling/Alteration | No Violations Noted | TOP HOLE IS COMPLETE. THE RIG IS MOVING FROM THE PAD. |
2213881 | Primary Facility | 2013-10-16 | Drilling/Alteration | No Violations Noted | THE WELL IS COVERED WITH A STEEL PLATE. PAD PROTECTION HAS BEEN LEFT DOWN. |
2223187 | Primary Facility | 2013-11-14 | Drilling/Alteration | No Violations Noted | TOP HOLE DRILLING IS COMPLETE. |
2227170 | Primary Facility | 2013-11-25 | Drilling/Alteration | No Violations Noted | TOP HOLE COMPLETE. 8 5/8" CASING SET AT 2006'. RIG ON THE PAD WILL FINISH THIS WELL. |
2227173 | Primary Facility | 2013-12-05 | Drilling/Alteration | No Violations Noted | TOP HOLE COMPLETE AT 2,020'. PATTERSON RIG WILL FINISH THE HOLE. THE SITE IS IN GOOD CONDITION. |
2231780 | Primary Facility | 2013-12-11 | Drilling/Alteration | No Violations Noted | TOP HOLE DRILLED TO 2020'. PATTERSON 259 WILL MOVE TO THIS WELL AND FINISH DRILLING. |
2232278 | Primary Facility | 2013-10-10 | Routine/Complete Inspection | No Violations Noted | This well targets the Geneseo Shale formation. This well was partially drilled and properly labeled. The inspection for this well was conducted concurrently with the inspection for site number 768793 (inspection report # 2232277.) Impoundment was dug and unlined. No erosion or sedimentation issues were apparent. |
2232813 | Primary Facility | 2013-11-05 | Routine/Complete Inspection | No Violations Noted | This well targets the Geneseo Shale formation. The inspection for this well was conducted concurrently with the inspection for site number 768793 (inspection report # 2232809.) Temporary stabilization appeared adequate. No erosion or sedimentation issues were observed. |
2232823 | Primary Facility | 2013-11-12 | Routine/Complete Inspection | No Violations Noted | This well targets the Geneseo Shale formation. The inspection for this well was conducted concurrently with the inspection for site number 768793 (inspection report # 2232820.) Water impoundment was being lined. No erosion or sedimentation issues were apparent. |
2236882 | Primary Facility | 2014-01-13 | Routine/Complete Inspection | No Violations Noted | This well targets the Geneseo Shale formation. The inspection for this well was conducted concurrently with the inspection for site number 768793 (inspection report # 2236823.) Two minor slips were noted on pad's embankments. Crews were erecting equipment in preparation for stimulation operations. An above ground storage tank (AST) was being erected. Inspector confirmed with operator's representative that it would be used for flow back fluids. Operator's representative agreed to provide a copy of the OG-71 for the AST. |
2247357 | Primary Facility | 2014-01-02 | Drilling/Alteration | No Violations Noted | THE SITE IS BEING PREPARED FOR PRESSURE TEST AND FRAC. |
2247360 | Primary Facility | 2014-01-14 | Drilling/Alteration | No Violations Noted | WELL IS BEING TESTED AS PART OF THE STIMULUS PROCESS. |
2251836 | Primary Facility | 2014-02-11 | Drilling/Alteration | No Violations Noted | WELL IS DRILLED. RIG IS GONE. SNOW REMOVAL IS THE ONLY ACTIVITY. |
2255752 | Primary Facility | 2014-03-17 | Drilling/Alteration | No Violations Noted | FRAC PLUGS ARE DRILLED OUT. FLOWBACK HAS NOT STARTED. |
2255756 | Primary Facility | 2014-03-13 | Drilling/Alteration | No Violations Noted | FRAC PLUGS ARE DRILLED OUT. WELL IS READY FOR FLOWBACK. |
2257676 | Primary Facility | 2014-03-20 | Drilling/Alteration | No Violations Noted | FRAC PLUGS HAVE BEEN DRILLED OUT, BUT FLOWBACK OPS HAVE NOT STARTED. |
2259858 | Primary Facility | 2014-04-01 | Drilling/Alteration | No Violations Noted | FLOWBACK HAS STARTED, AND THE WELL IS FLARED. |
2275106 | Primary Facility | 2014-04-07 | Drilling/Alteration | No Violations Noted | FLOWBACK IS COMPLETE. THE WELL IS NO LONGER FLARED. THE SITE IS OK. |
2361477 | Primary Facility | 2015-04-10 | Routine/Partial Inspection | No Violations Noted | |
2372410 | Primary Facility | 2015-04-20 | Drilling/Alteration | No Violations Noted | ALL FRAC PLUGS ARE DRILLED OUT. THEY WILL RUN TUBING. THE SITE IS OK. |
2374329 | Primary Facility | 2015-05-26 | Routine/Complete Inspection | No Violations Noted | |
2391271 | Primary Facility | 2015-07-17 | Drilling/Alteration | No Violations Noted | THIS WELL IS FRACED AND BEING HOOKED UP FOR PRODUCTION. |
2392557 | Primary Facility | 2015-07-17 | Routine/Complete Inspection | No Violations Noted | |
2439248 | Primary Facility | 2016-01-04 | Routine/Complete Inspection | No Violations Noted | |
2439250 | Primary Facility | 2016-01-04 | Routine/Complete Inspection | No Violations Noted | |
2478963 | Primary Facility | 2016-04-22 | Routine/Complete Inspection | No Violations Noted | |
2561368 | Primary Facility | 2017-02-14 | Routine/Complete Inspection | No Violations Noted | On 2/14/2017, Brian MacQuarrie onsite at unconventional well site. Act 9 sign in place. Erosion and Sedimentation Plan onsite. Three wells in production. Wells properly tagged. Two 400 bbl tanks installed within stainless steel containment structure. Freshwater impoundment maintained and fenced in. Erosion and Sedimentation Best Management Practices installed and maintained. Site stabilized with vegetative growth in previously disturbed areas. No apparent E/S issues. |
2666341 | Primary Facility | 2017-12-01 | Routine/Complete Inspection | No Violations Noted | Site had been constructed as outlined in the E&S plan contained within the ESCGP. All site and access road erosion controls had been implemented and properly maintained. There was no observed accelerated erosion or sedimentation in relation to the site or access road. All disturbed areas had been stabilized with vegetation attaining 70% uniform vegetative cover. Well appeared to be equipped for production. Two produced fluids tanks were located onsite within containment. Both the tanks and containment appeared to be in sound condition. |
2683656 | Primary Facility | 2018-01-18 | Routine/Complete Inspection | No Violations Noted | Site had been constructed as outlined within the E&S Plan contained within the ESCGP. Evaluation of erosion control functionality and maintenance was not feasible due to snow and ice conditions. Well appeared to be equipped for production. Two brine tanks were located onsite within secondary containment. Both the tanks and containment appeared to be in sound condition. Well development impoundment located onsite and it was observed to contain frozen fluids and snow. |
2698790 | Primary Facility | 2018-02-27 | Routine/Complete Inspection | No Violations Noted | Site and access road had been constructed in accordance with the ESCGP. All site and access road erosion controls had been implemented and maintained properly. All disturbed slopes and soil stockpiles had been stabilized with vegetation. There was no observed accelerated erosion or sedimentation in relation to the site or access road. It was noted that significant precipitation events had recently ceased. Two produced fluids tanks were located onsite within secondary containment. Both the tanks and containment appeared to be in sound condition. There was an Act 9 sign located onsite in accordance with 25 Pa Code Chapter 78a.55(i). |
2761043 | Primary Facility | 2018-08-07 | Complaint Inspection | No Violations Noted | At the time of inspection well equipped for production. Two brine tanks within secondary containment and appears structurally sound. GPUs within containment. No E&S issues. |
For data sources see[7]