X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20073

Well Details

Well ID: 115-20073
Loading map...
County: Susquehanna
Municipality: Auburn Township
Operator Name: CHESAPEAKE APPALACHIA LLC
Farm/Lease Name: CLAPPER 627103 2H
First Permit Date: 2008-12-16
Last Permit Date: 2008-12-16
Spud Date: 2009-04-04
Unconventional: Yes
Horizontal: Yes
Producing: Yes
Violations: None
Latitude: 41.716858
Longitude: -76.076555

Well Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
1794662 2009-04-29 No Violations Noted An existing road was used to access the well site. The road and drill pad are stoned with limestone. The Site ID sign and E/S Plan were present at the entrance of the access road. The pit had approximately 5' of freeboard. At the time of inspection, the depth of drilling was at 6750'. According to the drillers' log on site, Marcellus was encountered at approximately 6685'. Some small shows of gas were encountered as noted on inspection form.
1799725 2009-05-21 No Violations Noted At the time of inspection, the drilling crew was tripping drill pipe out of the hole. The company man indicated that the pipe was tripped out once in order to replace a bad motor. Upon resuming drilling after replacing the motor, there was a spike in pressure. During inspection it was not known what caused the pressure spike, but likely was a result of mud stuck in the pipe from setting it down in the rat hole. Drilling depth was 12,122'.

During inspection, pump trucks were also on site pumping out liquid from the pit. Approximately 6' of freeboard was observed in the pit.


1822436 2009-08-18 No Violations Noted At time of inspection I met with Company Man Max Oliver of Chesapeake. Mr. Oliver informed me they were getting ready to perforate Clapper 2H and 4H wells. A small service rig was on site and set up over the hole. Mr. Oliver indicated they are planning to perforate approximately 6 sections on each well. Fracking is tentatively secheduled for Sept. 7th. Frac tanks were being staged on an upper field near the entrance to the property. An excavator was also on site filling in the reserve pit with soil from adjacent stockpile. Pit was being compacted with sheepsfoot roller, and soil was hauled with large dump truck. Pipe line workers were also installing pipe near the access road to the well pad.
1853171 2010-01-04 No Violations Noted During a previous DEP inspection completed on 12/11/09, a violation was cited for failure to properly install a well tag on the completed well. On January 4th 2010, the DEP received a letter and a picture from Chesapeake in response to the violation. The letter indicates that a well tag was installed on the well on 12/19/09, which was made evident in a photograph received along with the letter.

Based on the above letter and photograph received, the operator has properly tagged the well, and the previous violation has been corrected.

1968895 2011-04-20 No Violations Noted Well is online. Inspected cellar. no evidence of bubbling. Well is protected by chain-link fence. No activity on site. No violations observed.
2047583 2012-03-05 No Violations Noted
2047596 2012-03-05 No Violations Noted Review weekly/post-storm inspections for 11/7 thru 12/26/2011.

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-2 428935.0 177.0 0.0 0.0 0.0 0.0
2012-1 440528.0 182.0 0.0 0.0 0.0 0.0
2011-2 597825.0 184.0 0.0 0.0 0.0 0.0
2011-1 662351.0 180.0 0.0 0.0 0.0 0.0
2010-2 1012973.0 184.0 0.0 0.0 0.0 0.0
2010-3 2841152.0 270.0 0.0 0.0 0.0 0.0
2009-0 1041611.0 92.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-2 PRODUCED FLUID 55.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR HYDRAULIC FRACTURING
2010-3 FRACING FLUID WASTE 4795.0 Bbl IDENTIFY METHOD IN COMMENTS NOT LISTED (PROVIDE NAME & ADDRESS IN COMMENTS) PA
2010-3 FRACING FLUID WASTE 195.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451 SUNBURY GENERATION WASTE WATER TRMT FAC SHAMOKIN DAM PA
2011-1 FRACING FLUID WASTE 18.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING PA
2011-2 FRACING FLUID WASTE 18.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE OF BRINE TO FRAC A WELL
2012-1 PRODUCED FLUID 18.2 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR HYDRAULIC FRACTURING