X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20121

Well Details

Well ID: 37-115-20121
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Springville Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 149128
Farm/Lease Name: R HULL 2H
License Status: Active
Spud Date: 06/09/2009
Permit Date: 3/6/2009
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.711919
Longitude: -75.900936

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 0.00 0.00 0.00
2010 CABOT OIL & GAS CORP 796,201.50 191 0.00 0 0.00 0
2011 CABOT OIL & GAS CORP 770,528.56 280 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 656,455.43 336 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 369,797.26 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 265,149.02 353 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 157,562.74 306 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 214,684.80 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 159,947.38 362 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 140,323.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 32,771.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-2 Basic Sediment (in Barrels) 2.59 Bbl LANDFILL 101534
2010-2 Drill Cuttings (in Tons) 69.50 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 101247
2010-2 Drill Cuttings (in Tons) 113.00 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 8-4630-00010/00
2010-2 Drill Cuttings (in Tons) 1.50 Tons LANDFILL 100955
2010-2 Drill Cuttings (in Tons) 113.00 Tons LANDFILL NY # 02S17
2010-2 Drill Cuttings (in Tons) 19.70 Tons LANDFILL NY # 50S08
2010-2 Drilling Fluid Waste (in Barrels) 11,190.47 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2010-2 Drilling Fluid Waste (in Barrels) 138.10 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010-2 Drilling Fluid Waste (in Barrels) 229.40 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010-2 Drilling Fluid Waste (in Barrels) 1,309.50 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0026034
2010-2 Produced Fluid (in Barrels) 210.46 Bbl REUSE OTHER THAN ROAD SPREADING
2011-1 Basic Sediment (in Barrels) 0.07 Bbl LANDFILL 101534
2011-1 Produced Fluid (in Barrels) 153.20 Bbl REUSE OTHER THAN ROAD SPREADING
2011-2 Basic Sediment (in Barrels) 0.52 Bbl LANDFILL 101534
2011-2 Produced Fluid (in Barrels) 78.29 Bbl REUSE OTHER THAN ROAD SPREADING
2012-1 Basic Sediment (in Barrels) 0.13 Bbl LANDFILL 100081
2012-1 Basic Sediment (in Barrels) 0.79 Bbl LANDFILL 101534
2012-1 Produced Fluid (in Barrels) 77.38 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Basic Sediment (in Barrels) 7.81 Bbl LANDFILL THR029
2012-2 Produced Fluid (in Barrels) 33.39 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2012-2 Produced Fluid (in Barrels) 875.93 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Produced Fluid (in Barrels) 233.83 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013-2 Produced Fluid (in Barrels) 111.02 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014-1 Produced Fluid (in Barrels) 93.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014-2 Produced Fluid (in Barrels) 130.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015-1 Produced Fluid (in Barrels) 63.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015-2 Produced Fluid (in Barrels) 54.63 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015-2 Produced Fluid (in Barrels) 81.15 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016-1 Produced Fluid (in Barrels) RWC 802 53.28 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016-2 Produced Fluid (in Barrels) RWC 802 103.64 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-02 Produced Fluid (in Barrels) RWC 802 35.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-05 Produced Fluid (in Barrels) RWC 802 35.22 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-09 Produced Fluid (in Barrels) RWC 802 39.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017-10 Produced Fluid (in Barrels) RWC 802 1.97 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-02 Produced Fluid (in Barrels) RWC 802 8.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-03 Produced Fluid (in Barrels) RWC 802 6.10 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-05 Produced Fluid (in Barrels) RWC 802 23.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019-01 Produced Fluid (in Barrels) RWC 802 21.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019-03 Produced Fluid (in Barrels) RWC 802 11.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1806421 Primary Facility 06/19/2009 Drilling/Alteration No Violations Noted Patterson Rig #154 on Site. Depth of drilling at 2893'. According to Company Man, they encountered water from surface. They drilled with mud in surface hole due to excessive water. At time of inspection, drilling with air using 8 3/4" bit. Will run 5-1/2" casing to TD of 10,430'.
1811406 Primary Facility 07/07/2009 Drilling/Alteration No Violations Noted Drill rig on site is Patterson Rig #154. Depth of drilling at time of inspection was TD -10,136'. According to Company Man, open-hole logs were run in the hole. The drill string was being tripped out at the time of inspection. The Company Man indicated they will likely start running 5-1/2 casing to TD sometime tomorrow.
1845001 Primary Facility 10/19/2009 Follow-up Inspection No Violations Noted At the time of inspection there was no activity on site. The well has not been fracced yet. There is no evidence of gas bubbling in the cellar of the well.
1852379 Primary Facility 12/23/2009 Follow-up Inspection Violation(s) Noted My inspection revealed an unpermitted discharge of stimulation fluids occurred at the site. This is a violation of 25 PA Code 78.54 General Requirements, which provides, in part: "The well operator shall control and dispose of fluids, residual waste and drill cuttings, including tophole water, brines, drilling fluids, drilling muds, stimulation fluids, well servicing fluids, oil, production fluids and drill cuttings in a manner that prevents pollution of the waters of this Commonwealth..."
1884555 Primary Facility 01/05/2010 Routine/Complete Inspection No Violations Noted
1884582 Primary Facility 01/15/2010 Follow-up Inspection Violation(s) Noted This well is currently being hydrofractured. The Hull 1H and 3V are also on this pad. On site to evaluate a self reported spill of fluid. The operator has reported that approximately 1 bbl of brackish fluid escaped secondary containment and impacted the ground. The fluid was excavated by the time I reached the site. It was recommend that the operator use the Act 2 attainment standards for clean-up. No E/S problems were noted while on site. Contact Mike O'Donnell at 570.826.2300 with questions.
1890365 Primary Facility 05/24/2010 Routine/Complete Inspection No Violations Noted
2007354 Primary Facility 09/01/2011 Routine/Complete Inspection No Violations Noted
2009185 Primary Facility 09/21/2011 Follow-up Inspection No Violations Noted
2009288 Primary Facility 10/05/2011 Follow-up Inspection No Violations Noted
2009432 Primary Facility 10/06/2011 Follow-up Inspection No Violations Noted
2021729 Primary Facility 10/12/2011 Follow-up Inspection Violation(s) & Outstanding Violations I arrived at the site at 10:20 AM to conduct a Follow-Up Inspection regarding the observation of daylighted liner noted in five (5) areas on the surface of the well pad during the 9-1-11 inspection conducted bty the Department and potentially the apperance of drilling residuals on the surface of the well pad during the 9-21-11 inspection. The outstanding violation of Pollution prevention measure, Section 402 Clean Streams Law can be referenced in the 9-1-11, 9-2-11, 9-21-11, 10-5-11 and 10-6-11 inspection reports. The new violations observed during the inspection are, Section 25 Pa. Code §78.56(a) and section 301 of the PA Solid Waste Management Act, 35 P.S. §6018.301, due to the compromised liner intergrity observed during the excavation of the test pits and the drilling residuals contacting the surface of the ground.
2021759 Primary Facility 10/12/2011 Follow-up Inspection No Violations Noted Please refer to R Hull 1H well inspection report regarding violations and outstanding violations.
2024043 Primary Facility 10/26/2011 Follow-up Inspection No Violations Noted Violations and specifics pertaining to this inspection report can be associated with the R Hull 1H inspection report. Permit Number is 115-20122.
2024047 Primary Facility 10/27/2011 Follow-up Inspection No Violations Noted Violations and specifics associated with this inspection report can be referred to in the R Hull 1H inspection report. Permit Number is 115-20122.
2024055 Primary Facility 11/29/2011 Administrative/File Review No Violations Noted Violations and specifics pertaining to this inspection report can be referred to in the R Hull 1H inspection report. Permi number is 115-20122.
2024675 Primary Facility 10/13/2011 Follow-up Inspection No Violations Noted Violations and specifics associated with this inspection report can be referred to in the R Hull 1H 10-12-11 inspection report. Permit number is 115-20122.
2024680 Primary Facility 10/28/2011 Follow-up Inspection No Violations Noted Violations ansd specifics associated with this inspection report can be referred to in the R Hull 1H 10-28-11 inspection report. Permit number is 115-20122.
2024710 Primary Facility 10/31/2011 Follow-up Inspection No Violations Noted Violations and specifics associated with this inspection report can be referred to in the R Hull 1H 10-31-11 inspection report. Permit number is 115-20122.
2347642 Primary Facility 02/25/2015 Routine/Partial Inspection No Violations Noted The Department was on site at the R Hull Well Site located at 1197 Phillips Road Springville Township, to conduct a Routine Partial Inspection. During the Department’s inspection, the E&S Plan was on site and the E&S Inspection log showed that Sam Wiernusz (TEC) conducted a weekly inspection on 2/25/15. At the time of the inspection, the site was snow covered. No obvious E&S issues were observed.
2534943 Primary Facility 2016-11-04 Routine/Complete Inspection No Violations Noted
2570365 Primary Facility 2017-03-06 Routine/Complete Inspection No Violations Noted Prior to conducting the site inspection I reviewed the Well Site Restoration Report which was submitted on 16OCT2015. There was activity occurring at the site during the inspection.
2601260 Primary Facility 2017-06-06 Administrative/File Review No Violations Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1884582 587048 01/15/2010 05/11/2010 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative 78.56 Failure to contain a pollutional substance in a lined pit or tank
2021729 625363 10/12/2011 11/29/2011 402POTNLPOLL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit. Environmental Health & Safety Viols entered at this insp being addressed thru further action entered at R Hull 1H Permit 115-20122. MBC 12/1/2011
2021729 625364 10/12/2011 11/29/2011 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative Viols entered at this insp being addressed thru further action entered at R Hull 1H Permit 115-20122. MBC 12/1/2011
2021729 625365 10/12/2011 11/29/2011 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Viols entered at this insp being addressed thru further action entered at R Hull 1H Permit 115-20122. MBC 12/1/2011

For data sources see[6]

References