Well ID: 34-151-25839 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.749026745,"lon":-81.18899872,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Stark | |
Municipality: Paris Township | |
Operator Name: DORFMAN PRODUCTION COMPANY | |
Well Pad ID: | |
Farm/Lease Name: STAIB UNIT | |
License Status: Producing | |
License Date: 2013-08-07 | |
Spud Date: 2013-08-20 | |
Spud Drilling Contractor: ADVENT DRLG | |
Final Drill Date: 2013-08-29 | |
Well Total Depth: 5476 ft | |
Configuration: Vertical | |
Latitude: 40.749026745 | |
Longitude: -81.18899872 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-08-07 | Proposed Formations:CLINTON, Issued Date:8/7/2013, Expired Date:8/7/2015 12:00:00 PM, Drilling unit acres:131.7, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2013-08-29 | |
Completion Report Received | 2013-11-04 | |
Construction Permit Expires | 2015-08-07 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-11-06 | 5213 | 5302 | 49 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-09-11 | H2O | 15 | 162000 Gal | 100000 | OTHER | Nabors Services |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | DORFMAN PRODUCTION COMPANY | 7681 | 625 | 92 |
2014 | DORFMAN PRODUCTION COMPANY | 4768 | 571 | 365 |
2015 | DORFMAN PRODUCTION COMPANY | 3788 | 388 | 365 |
2016 | DORFMAN PRODUCTION COMPANY | 3364 | 340 | 365 |
2017 | DORFMAN PRODUCTION COMPANY | 3147 | 296 | 365 |
2018 | DORFMAN PRODUCTION COMPANY | 2951 | 287 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | DORFMAN PRODUCTION COMPANY | Brine | 2910 | 92 |
2014 | DORFMAN PRODUCTION COMPANY | Brine | 508 | 365 |
2015 | DORFMAN PRODUCTION COMPANY | Brine | 420 | 365 |
2016 | DORFMAN PRODUCTION COMPANY | Brine | 385 | 365 |
2017 | DORFMAN PRODUCTION COMPANY | Brine | 350 | 365 |
2018 | DORFMAN PRODUCTION COMPANY | Brine | 233 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
1288686534 | 2015-05-04 | Preliminary Restoration | No Violations | I was on location to check preliminary restoration for this well. The lease road is gated, graveled and stable. The electric driven pumpjack well has proper identification, contains a house gas connection and is in good mechanical condition. The wellhead does not contain the required valve on the surface-production casing annulus to allow continual monitoring of mechanical integrity. The tank battery is shared with wells #25670, 25689 and 25686 and contains a 210bbl production tank, 100bbl brine tank, vertical mechanical separator and proper identification. Vegetation has been established at the well site and tank battery. Spacing requirements for the wellhead, tank battery and roadways are all conforming to regulations. I have contacted Greg New of Dorfman informing him that the pressure gauge must be installed before preliminary restoration can be passed. |
For data sources see[9]