Well ID: 34-151-24987 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.89980179,"lon":-81.27743067,"icon":""}]} |
County: Stark | |
Municipality: | |
Operator Name: ENERVEST OPERATING L | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1996-05-28 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Active Injection | |
Violations: 0 | |
Latitude: 40.89980179 | |
Longitude: -81.27743067 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
1996-0 | 2729.0 | 3204.0 | ||||
1997-0 | 6853.0 | 5785.0 | ||||
1998-0 | 4397.0 | 3517.0 | ||||
1999-0 | 2649.0 | 1814.0 | ||||
2000-0 | 2801.0 | 1885.0 | ||||
2001-0 | 2763.0 | 1536.0 | ||||
2002-0 | 2720.0 | 1340.0 | ||||
2003-0 | 2244.0 | 1173.0 | ||||
2004-0 | 2146.0 | 1035.0 | ||||
2005-0 | 1796.0 | 833.0 | ||||
2006-0 | 1719.0 | 783.0 | ||||
2007-0 | 1516.0 | 711.0 | ||||
2008-0 | 1417.0 | 559.0 | ||||
2010-0 | 1086.0 | 1217.0 | ||||
2011-0 | 996.0 | 476.0 | ||||
2013-0 | 26.0 | 0.0 | ||||
2014-0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
1001208747 | 2012-11-26 | I inspected the Flintkote (ERP #1) No. 37 (34151249870000) injection well on November 26, 2012; I was accompanied by Steve Ochs. There were no violations at the wellhead or at the brine tanks. | ||||
-1197507575 | 2014-07-24 | There were no violations at the time of inspection. | ||||
-1304605512 | 2013-09-30 | There were no violations at the time of my inspection. | ||||
1324259161 | 2011-12-14 | Rick Kepler called me for a Mechanical Integrity Test (MIT). When I arrived at the site, a new Halliburton PLT packer was run by Bishop Well Service on 2.375 EUE tubing and set at 4666' (36' above the top perforation) with 10,000 pounds compression. Universal Well Services pumped and circulated 101 barrels of packer inhibitor in the annulus. The annulus was pressured up to 1120 PSI. The test was started at 1120 PSI and ended at 1110 PSI after 21 minutes. The MIT PASSED. Rick Kepler (EnerVest) will submit a tubing tally to Tom Tomastik at the Columbus office. The allowable injection pressure for this well is 1080 psi. | ||||
13512 | PASSED Y WITNESSED 10/1/96 INSPECTOR BRETT FARNSWORTH DATE 10/0119/96 DATA FROM OLD VAX INFO | |||||
144179738 | 2014-12-12 | The injection well and surface facility were inspected. There were no violations found at the time. | ||||
1462742295 | 2014-09-16 | There were no violations found at the time. | ||||
1684182125 | 2014-04-21 | There were no violations found at the time of inspection. | ||||
1861328995 | 2014-05-30 | An inspection of the well and injection facility found no violations. | ||||
1941020086 | 2012-03-30 | I witnessed the testing of the flowline to 1325 PSI for 45 minutes. There was no loss in pressure - test passed. | ||||
-48354451 | 2012-06-11 | My inspection of this well site found no violations at this time. | ||||
-538987086 | 2013-12-27 | There were no violations at the time of inspection. | ||||
-552651187 | 2014-03-06 | There were no violations at the time of inspection. | ||||
675657973 | 2011-06-29 | This well was inspected as part of a Enhanced Recovery Project. This well will be used as an injection site. Once the production well pumping unit is removed and the well is converted into an injection well, place a containment dike around the well head and fence off the site. | ||||
-743356701 | 2012-11-26 | Ryan Channell and I inspected the surface facility and injection well and found no violations. | ||||
-906489295 | 2015-03-16 | The injection well and surface facility were inspected. There were no violations found at the time. |
For data sources see[2]