34-169-24551

Well Details

Well ID: 34-169-24551
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1988-09-02
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 40.9537177628
Longitude: -81.7997675685

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1129063820 2006-10-23 Arvilla is working on cutting off 5 inch at 2300 ft. after getting inside at 1700 ft.
-1514384813 2006-10-27 Test plug which was set Thursday at 2240 ft. and test passed .Next return to plug from 2046 ft. to 0 ft. in 500 sections to surface .Halliburton
-1530855731 2006-11-07 Pits are closed and pipe has been plated with permit number .NO leaks
-184596006 2010-12-10 Check this well for Erica Freeman and found that the well has been plugged but needs a marker on top of well with correct permit info. Met with operator and advise of marker and valves.
-298873939 2013-10-23 There were no violations at the time of inspection.
1136737816 2013-03-21 Appears to be in compliance.
1210i3857193 2002-03-02 Well is unhooked from lines. Need to check to see if P&A permit issued. Well is incapable of production. Accompanied by Tom T. & Dave H..
137213422 2006-10-25 W/O wire line truck to set bridge plug .Set plug at 2240 ft. and then wait on water truck .Then try and fill casing and could not after two trucks .Test on bridge plug failed .
1704431376 2003-12-09 CHECKED ID - OK
192975750 2007-01-02 Plate with I.D. welded on top of well .Area graded , pits closed .
395000256 2006-10-24 Cut off 2300 ft. and clean out well with scraper so bridge plug could be set .
825085149 2006-10-26 Run in hole with tubing and set plug from 2240 to 2040 ft. and pull up and reverse circulate to clear cement .Need to let cement set before test can be done .
948312009 2006-10-19 Plug scheduled today will not go off because could not get bridgeplug to set .
PL214 Preliminary Restoration done information from Data Point