X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-003-22233"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-003-22233
 
| Well ID: 37-003-22233
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.634541, -79.753625 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.634542, -79.753625 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Allegheny County, Pennsylvania|Allegheny]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Fawn Township, Allegheny County, Pennsylvania|Fawn Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Allegheny_County,_Pennsylvania|Allegheny]]
 +
|-
 +
| Municipality: [[Fawn Township,_Allegheny_County,_Pennsylvania|Fawn Township]]
 
|-
 
|-
 
| Operator Name: [[RANGE RESOURCES APPALACHIA LLC]]
 
| Operator Name: [[RANGE RESOURCES APPALACHIA LLC]]
 
|-
 
|-
| Well Pad ID: [[146710|146710]]
+
| Well Pad ID: [[146710]]
 
|-
 
|-
 
| Farm/Lease Name: BOVARD DOROTHY UNIT 8H
 
| Farm/Lease Name: BOVARD DOROTHY UNIT 8H
 
|-
 
|-
| First Permit Date: 2012-08-16
+
| License Status: Active
|-
 
| Last Permit Date: 2012-08-16
 
 
|-
 
|-
| Spud Date: 2012-10-30
+
| Spud Date: 10/30/2012
 
|-
 
|-
| Unconventional: Yes
+
| Permit Date: 8/16/2012
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Well Status: ACTIVE
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: 0
+
| Latitude: 40.634542
|-
 
| Latitude: 40.634541
 
 
|-
 
|-
 
| Longitude: -79.753625
 
| Longitude: -79.753625
|-
 
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2012-2
+
| 2012
| style="text-align:right;" | 0.0
+
| [[RANGE RESOURCES APPALACHIA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2013
 +
| [[RANGE RESOURCES APPALACHIA LLC]]
 +
| style="text-align: right;" | 1,315,796.70
 +
| style="text-align: right;" | 235
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2013-1
+
| 2014
| style="text-align:right;" | 408221.82
+
| [[RANGE RESOURCES APPALACHIA LLC]]
| style="text-align:right;" | 52.0
+
| style="text-align: right;" | 916,174.23
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 320
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
|-
+
| style="text-align: right;" | 0
|-
 
| 2013-2
 
| style="text-align:right;" | 907574.88
 
| style="text-align:right;" | 183.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2015
 +
| [[RANGE RESOURCES APPALACHIA LLC]]
 +
| style="text-align: right;" | 702,748.96
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2014-1
+
| 2016
| style="text-align:right;" | 540783.56
+
| [[RANGE RESOURCES APPALACHIA LLC]]
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 512,852.76
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 356
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2017
 +
| [[RANGE RESOURCES APPALACHIA LLC]]
 +
| style="text-align: right;" | 407,743.91
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2014-2
+
| 2018
| style="text-align:right;" | 375390.67
+
| [[RANGE RESOURCES APPALACHIA LLC]]
| style="text-align:right;" | 139.0
+
| style="text-align: right;" | 342,376.46
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 314
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| 2019
| 2015-02
+
| [[RANGE RESOURCES APPALACHIA LLC]]
| style="text-align:right;" | 61591.01
+
| style="text-align: right;" | 84,299.10
| style="text-align:right;" | 28.0
+
| style="text-align: right;" | 90
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
|-
 
|-
 
| 2015-01
 
| style="text-align:right;" | 74976.29
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-03
 
| style="text-align:right;" | 65474.46
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Waste Type
!scope="col" | QUANTITY
+
!scope="col" | Quantity
!scope="col" | UNITS
+
!scope="col" | Disposal Method
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
 
| 2012-2
 
| 2012-2
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 542.82
+
| style="text-align: right;" | 542.82 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 100434
 
| 100434
| EVERGREEN LANDFILL
 
| BLAIRSVILLE
 
| PA
 
|-
 
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 262.16
+
| style="text-align: right;" | 262.16 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 100172
 
| 100172
| ARDEN LANDFILL
 
| WASHINGTON
 
| PA
 
|-
 
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 174.29
+
| style="text-align: right;" | 174.29 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 100280
 
| 100280
| VALLEY LANDFILL
 
| IRWIN
 
| PA
 
 
|-
 
|-
 +
| 2013-1
 +
| Drilling Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 1,619.52 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| DRILLING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 11,111.07 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| FLOWBACK FRACTURING SAND
+
| Fracturing Fluid Waste (in Tons)
| style="text-align:right;" | 21.19
+
| style="text-align: right;" | 21.19 Tons
| Tons
 
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
| PAD980707442
+
| 101532
| WEAVERTOWN TRANSPORTATION  LEASING INC
 
| MCDONALD
 
| PA
 
 
|-
 
|-
 +
| 2013-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 8,031.83 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2013-1
+
| 2013-2
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 11.0
+
| style="text-align: right;" | 5,724.64 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2014-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 202.91 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2014-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,889.76 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 4,807.52 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 3,336.20 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
| 2013-1
+
| 2015-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 8.0
+
| style="text-align: right;" | 3,111.62 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 945.68 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 112.50 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,436.25 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-1
 +
| Fracturing Fluid Waste (in Barrels) RWC 805
 +
| style="text-align: right;" | 8.04 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2016-1
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 154.70 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2016-1
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 137.50 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2016-1
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,317.50 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 437.50 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
| 2013-2
+
| 2016-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 5.0
+
| style="text-align: right;" | 187.74 Bbl
| Bbl
+
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 840.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017-01
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 7.75 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2017-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 24.88 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2017-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.25 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-02
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 1.01 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 14.05 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.99 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-03
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 3.69 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
| 2014-1
+
| 2017-03
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 202.91
+
| style="text-align: right;" | 11.32 Bbl
| Bbl
+
| RESIDUAL WASTE PROCESSING FACILITY
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
 
| WMGR123SW005
 
| WMGR123SW005
| RESERVED ENV SVC HEMPFIELD TWP RESIDUAL WASTE OPER
+
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 28.18 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-04
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 1.89 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2017-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 29.95 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-1
+
| 2017-05
| PRODUCED FLUID
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 6.41 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 24.40 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-06
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 1.25 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 14.34 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 
|-
 
|-
| 2014-2
+
| 2017-06
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 4.0
+
| style="text-align: right;" | 14.38 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017-07
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 4.21 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW009
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 19.94 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
|}
+
| 2017-08
For data sources see<ref>{{cite web
+
| Produced Fluid (in Barrels) RWC 802
| title = Oil and Gas Historical Waste Report
+
| style="text-align: right;" | 15.30 Bbl
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| RESIDUAL WASTE PROCESSING FACILITY
| date = 2015-05-26
+
| WMGR123SW019
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
|-
| accessdate = 2015-05-26 }}</ref>
+
| 2017-08
== Inspection Data ==
+
| Produced Fluid (in Barrels) RWC 802
{| class="wikitable sortable" width="95%"
+
| style="text-align: right;" | 43.38 Bbl
!scope="col" | INSPECTION ID
+
| REUSE (AT WELL PAD)
!scope="col" | DATE
+
|  
!scope="col" | DESCRIPTION
 
!scope="col" | COMMENT
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
| 2106136
+
| 2017-09
| 2012-10-10
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| No Violations Noted
+
| style="text-align: right;" | 2.50 Bbl
| John Ley Water Quality Specialist SWRO was on site to conduct a preoperational inspection.  The site sign was in place and properly displayed the permits.  The site E&S controls and BMP's were well constructed and in good shape.  The access road was constructed according to plan and E&S controls had been added to the road.  The well pad was still under construction and was almost complete. The hillsides were being hydroseeded during the inspection to stabilize any bare ground.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 139.99 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-10
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 1.65 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.02 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
| 2116686
+
| 2017-10
| 2012-11-05
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 15.09 Bbl
| CONDUCTOR IS SET. FALCON 22 ONTHE PAD. SITE, E&S, AND ACCESS, OK.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-11
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 1.64 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 72.52 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 29.21 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 14.63 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 43.38 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 
|-
 
|-
| 2118835
+
| 2017-12
| 2012-11-13
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 67.65 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.75 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 71.17 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2018-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 27.62 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-02
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 1.49 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.67 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 40.90 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
| 2118899
+
| 2018-03
| 2012-11-27
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 42.53 Bbl
| TOP HOLE COMPLETE AT 5560'. A BIG RIG WILL FINISH.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 27.43 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 27.77 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.78 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 71.15 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2121284
+
| 2018-07
| 2012-12-04
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| No Violations Noted
+
| style="text-align: right;" | 6.85 Bbl
| TOP HOLE TD AT 5,560'. SITE IS OK.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 40.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.99 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-08
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 13.75 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.55 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 14.57 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 
|-
 
|-
| 2122998
+
| 2018-08
| 2012-12-11
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 13.69 Bbl
| John Ley Water Quality Specialist SWRO was on site to conduct a routine inspection.  The site sign was in place and properly displayed the permits.  The site E&S controls and BMP's were well constructed and in good shape.  The access road was constructed according to plan and E&S controls were working properly.  The well was drilled and being cemented.  The gathering line for the site was being constructed at the far side.  The BMP's were in place and hillsides in this area were temporarily stabilized.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-09
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 1.25 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 9.48 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.75 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW030
 
|-
 
|-
| 2124778
+
| 2018-10
| 2012-12-13
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 13.75 Bbl
| TOP HOLE COMPLETE. FALCON 22 HAS LEFT THE SITE.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 14.05 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW030
 +
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.03 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 14.24 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW030
 +
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 27.61 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2019-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 41.22 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2130108
+
| 2019-02
| 2013-01-14
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 27.38 Bbl
| John Ley WQS, SWRO was on site to conduct a routine inspection.  At the time of this inspection, the well sign, E&S plan, and the PPC plan  were onsite. The site was gated for security. The wells were being drilled. The ground around the site was snow covered but there did not appear to be any accelerated erosion or sedimentation issues.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 81.70 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 +
|-
 +
| 2106136
 +
| Primary Facility
 +
| 10/10/2012
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| John Ley Water Quality Specialist SWRO was on site to conduct a preoperational inspection.  The site sign was in place and properly displayed the permits.  The site E&S controls and BMP's were well constructed and in good shape.  The access road was constructed according to plan and E&S controls had been added to the road.  The well pad was still under construction and was almost complete. The hillsides were being hydroseeded during the inspection to stabilize any bare ground.
 +
|-
 +
| 2116686
 +
| Primary Facility
 +
| 11/05/2012
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| CONDUCTOR IS SET. FALCON 22 ONTHE PAD. SITE, E&S, AND ACCESS, OK.
 +
|-
 +
| 2118835
 +
| Primary Facility
 +
| 11/13/2012
 +
| Drilling/Alteration
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
 +
| 2118899
 +
| Primary Facility
 +
| 11/27/2012
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| TOP HOLE COMPLETE AT 5560'. A BIG RIG WILL FINISH.
 +
|-
 +
| 2121284
 +
| Primary Facility
 +
| 12/04/2012
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| TOP HOLE TD AT 5,560'. SITE IS OK.
 +
|-
 +
| 2122998
 +
| Primary Facility
 +
| 12/11/2012
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| John Ley Water Quality Specialist SWRO was on site to conduct a routine inspection.  The site sign was in place and properly displayed the permits.  The site E&S controls and BMP's were well constructed and in good shape.  The access road was constructed according to plan and E&S controls were working properly.  The well was drilled and being cemented.  The gathering line for the site was being constructed at the far side.  The BMP's were in place and hillsides in this area were temporarily stabilized.
 +
|-
 +
| 2124778
 +
| Primary Facility
 +
| 12/13/2012
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| TOP HOLE COMPLETE. FALCON 22 HAS LEFT THE SITE.
 +
|-
 +
| 2130108
 +
| Primary Facility
 +
| 01/14/2013
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| John Ley WQS, SWRO was on site to conduct a routine inspection.  At the time of this inspection, the well sign, E&S plan, and the PPC plan  were onsite. The site was gated for security. The wells were being drilled. The ground around the site was snow covered but there did not appear to be any accelerated erosion or sedimentation issues.
 
|-
 
|-
 
| 2131133
 
| 2131133
| 2013-01-07
+
| Primary Facility
 +
| 01/07/2013
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| TOP HOLE COMPLETE. THE WELL IS COVERD WITH A STEEL PLATE.
 
| TOP HOLE COMPLETE. THE WELL IS COVERD WITH A STEEL PLATE.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2131273
 
| 2131273
| 2013-01-15
+
| Primary Facility
 +
| 01/15/2013
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| TOP HOLE COMPLETE. RIG ON THE PAD WILL FINISH THE WELL.
 
| TOP HOLE COMPLETE. RIG ON THE PAD WILL FINISH THE WELL.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2134530
 
| 2134530
| 2013-01-28
+
| Primary Facility
 +
| 01/28/2013
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| TOP HOLE DRILLING COMPLETE. WELL WILL BE FINISHED NEXT ON THIS PAD.
 
| TOP HOLE DRILLING COMPLETE. WELL WILL BE FINISHED NEXT ON THIS PAD.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2143048
 
| 2143048
| 2013-02-07
+
| Primary Facility
 +
| 02/07/2013
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| DRILLING HORIZONTAL LEG AT 9'538'. SITE IS GOOD.
 
| DRILLING HORIZONTAL LEG AT 9'538'. SITE IS GOOD.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2156427
 
| 2156427
| 2013-04-10
+
| Primary Facility
 +
| 04/10/2013
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| WELL IS SET UP FOR FRACING.
 
| WELL IS SET UP FOR FRACING.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2165004
 
| 2165004
| 2013-04-24
+
| Primary Facility
 +
| 04/24/2013
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| WELL IS FRACED AND BEING PREPARED FOR FLOWBACK. THE SITE IS OK.
 
| WELL IS FRACED AND BEING PREPARED FOR FLOWBACK. THE SITE IS OK.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2172748
 
| 2172748
| 2013-05-28
+
| Primary Facility
 +
| 05/28/2013
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| WELL IS PRODUCING. SITE IN GOOD CONDITION.
 
| WELL IS PRODUCING. SITE IN GOOD CONDITION.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2173269
 
| 2173269
| 2013-05-20
+
| Primary Facility
 +
| 05/20/2013
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| This well was inspected concurrently with the Bovard Pad (site 750439, inspection record 2173221). Site appeared stabilized; no erosion or sedimentation issues were evident.
 
| This well was inspected concurrently with the Bovard Pad (site 750439, inspection record 2173221). Site appeared stabilized; no erosion or sedimentation issues were evident.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2187624
 
| 2187624
| 2013-07-11
+
| Primary Facility
 +
| 07/11/2013
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| WELL IS COMPLETE. ALL EQUIPTMENT IS HOOKED UP. ACCESS IS LOCKED.
 
| WELL IS COMPLETE. ALL EQUIPTMENT IS HOOKED UP. ACCESS IS LOCKED.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2196173
 
| 2196173
| 2013-08-13
+
| Primary Facility
 +
| 08/13/2013
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| This well was inspected concurrently with the Bovard Pad (site 750439, inspection record 2196159). Area surrounding well pad was mostly vegetated with some unvegetated patches. Water in containment around brine tanks was clear with no sheen visible. Site restoration has been extended until November 9, 2015.
 
| This well was inspected concurrently with the Bovard Pad (site 750439, inspection record 2196159). Area surrounding well pad was mostly vegetated with some unvegetated patches. Water in containment around brine tanks was clear with no sheen visible. Site restoration has been extended until November 9, 2015.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2231277
 
| 2231277
| 2013-12-19
+
| Primary Facility
 +
| 12/19/2013
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| This well was inspected concurrently with the Bovard Well Site (site 750439, inspection record 2231273). Site was snow covered at time of inspection. No erosion or sedimentation issues were evident. Production fluids were contained. This site has a restoration extension until November 9. 2015.
 
| This well was inspected concurrently with the Bovard Well Site (site 750439, inspection record 2231273). Site was snow covered at time of inspection. No erosion or sedimentation issues were evident. Production fluids were contained. This site has a restoration extension until November 9. 2015.
|
 
|
 
|
 
 
|-
 
|-
 +
| 2261726
 +
| Primary Facility
 +
| 04/11/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| This well was inspected concurrently with the Bovard Well Site (site 750439, inspection record 2261697). Well was drilled and equipped for production. Equipment was on site excavating cellars for additional wells.  No erosion or sedimentation issues were evident. Production fluids were contained. This site has a restoration extension until November 9. 2015.
 
|-
 
|-
| 2309990
+
| 2267348
| 2014-10-03
+
| Primary Facility
 +
| 04/30/2014
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
| Precision Drilling rig 181SL was on site engaged in drillling operations. Vegetative growth between soil pile and pad was sparse. Section of super silt fence partially knocked down near pipeline right of way. No spills of fluids were noted. Concurrently inspected site and its associated wells.  
+
| This well was inspected concurrently with the Bovard Well Site (site 750439, inspection record 2266776). This well appears equipped for production. Drill rig was on site for well 2H. No leaks of production fluid were evident. Incipient erosion channel was noted off southern end of pad inside LOD near stake for pipeline. Fabric was drooping on silt fence/super silt fence in two areas and should be mended. This site has a restoration extension until November 9. 2015.
|
 
|
 
|
 
 
|-
 
|-
|}
+
| 2289894
For data sources see<ref>{{cite web
+
| Primary Facility
| title = Oil and Gas Historical Inspection Report
+
| 07/03/2014
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| Routine/Complete Inspection
| date = 2015-05-26
+
| No Violations Noted
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
| THIS WELL IS COMPLETE AND PRODUCING. THE WELL IS PROTECTED BY A STEEL STRUCTURE AS THE NEW WELLS ARE DRILLED.
| accessdate = 2015-05-27 }}</ref>
 
[[Category:Has Chemical Data]]
 
==Chemical Data==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | HF Fluid Concentration
 
!scope="col" | Ingredient
 
!scope="col" | Additive Concentration
 
!scope="col" | Trade Name
 
!scope="col" | Purpose
 
!scope="col" | CAS number
 
!scope="col" | Supplier
 
 
|-
 
|-
| 0.00017
+
| 2309990
| 2-Amino-2-methyl-1-propanol
+
| Primary Facility
| 1.0
+
| 10/03/2014
| MC B-8520
+
| Routine/Complete Inspection
| Antibacterial Agent
+
| No Violations Noted
| 124-68-5
+
| Precision Drilling rig 181SL was on site engaged in drillling operations. Vegetative growth between soil pile and pad was sparse. Section of super silt fence partially knocked down near pipeline right of way. No spills of fluids were noted.
| Multichem
 
 
|-
 
|-
 +
| 2400642
 +
| Primary Facility
 +
| 08/07/2015
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On 8/7/15, I inspected the Bovard Dorothy site as a routine inspection and made the following observations:
 
|-
 
|-
| 75673.0
+
| 2410118
| 3
+
| Primary Facility
| 4.0
+
| 09/14/2015
| MC B-8520
+
| Routine/Complete Inspection
| Antibacterial Agent
+
| No Violations Noted
| 4
+
|  
| Multichem
 
 
|-
 
|-
 +
| 2410120
 +
| Primary Facility
 +
| 09/14/2015
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| THIS IS A WELL MAINTAINED GAS WELL.
 
|-
 
|-
| 100.0
+
| 2461553
| 4
+
| Primary Facility
| 51200.0
+
| 2016-02-25
| MC B-8520
+
| Routine/Complete Inspection
| Antibacterial Agent
+
| No Violations Noted
| 4-Dimethyloxazolidin
+
| THIS WELL AND PRODUCTION EQUIPTMENT HAVE BEEN WELL MAINTAINED.
| Multichem
+
THE PAD AND ACCESS ARE IN GOOD CONDITION.
 
|-
 
|-
 +
| 2504533
 +
| Primary Facility
 +
| 2016-04-07
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
| On 4/7/16, I performed a routine partial site inspection at the Dorothy Bovard site in response to a request from the operator and met with Range Resources representative Erica Taylor to review requested alteration to the shape of the pad post restoration.  The change was approved as a redline change as it did not appear to significantly change flow around the site and decreased impervious surface area slightly.
 
|-
 
|-
| 0.00204
+
| 2566366
| Polyol Ester
+
| Primary Facility
| 5.0
+
| 2016-11-16
| FRW-300
+
| Complaint Inspection
| Friction Reducer
+
| No Violations Noted
| Proprietary
+
| On 11/16/16, I performed a complaint inspection related to the Bovard site and made the following observations:
| FracTech
+
•The complainant reported that beginning in late September 2016 their well began producing gray water.  Within a few days the water changed to black with intermittent gray at which time the complainant called their well service company to inspect with inconclusive results.  At this time the floss filter was reported to have begun clogging regularly and a rotten egg odor was noted.
 +
•The complainant reported being in residence for 46-48 years.  The well bore is located roughly 10 feet from the house and had a secure cap elevated 6” off of the ground at the time of inspection.  The complainant reported that the well was drilled to 240 feet deep in 1988 and has a poly case to 220 feet.  The well was reported to have had prior issues with sediment.
 +
•Samples were taken from the well for 946 and bacteriological analysis before treatment and after a ten-minute flush.
 +
•Inspection of the well site found no i
 
|-
 
|-
 +
| 2571032
 +
| Primary Facility
 +
| 2017-01-13
 +
| Administrative/File Review
 +
| No Violations Noted
 +
| On 1/13/17, I performed an Admin inspection related to the Bovard Dorothy site in response to complaint 323595 and made the following observations:
 +
•Review of lab results for samples taken 11/16/17 as well as other situational information and found that, while water chemistry parameters were high in multiple instances, oil and gas impact was not conclusively indicated.
 
|-
 
|-
| 0.00204
+
| 2627013
| Sodium Chloride
+
| Primary Facility
| 5.0
+
| 2017-03-27
| FRW-300
+
| Complaint Inspection
| Friction Reducer
+
| No Violations Noted
| 7647-14-5
+
| On 3/27/2017 a COMPL inspection of the Bovard well and an associated site was completed in response to complaint 325615. The following was observed:
| FracTech
+
 +
>>E&S controls in multiple locations around the site were observed to be unnecessary and/or in poor repair. All controls should be removed or maintained as appropriate.
 +
 +
>>No evidence of spill or other surface contamination was noted in relation to possible water supply impact.
 +
 
 +
>>In response to reported bacterial contamination and off taste of the complainants drinking water samples were collected for SAC 946 and bacteriological analysis.
 +
 
 +
>>The distance from the water supply to the nearest applicable oil & gas activity is roughly 4100 feet.  No direct impact from the site was observed.
 +
 
 +
>>No evidence was observed at the time of inspection to indicate overt surface water impact.  The water well head was found to be in good condition.
 
|-
 
|-
 +
| 2657248
 +
| Primary Facility
 +
| 2017-11-06
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Well drilled and equipped for production. Well tag present. Well apparatus and brine tanks appear to be in sound condition. No accelerated erosion or sedimentation observed on well site or access road.
 
|-
 
|-
| 0.00204
+
| 2671054
| Oxyalkylated Alcohol
+
| Primary Facility
| 5.0
+
| 2017-09-11
| FRW-300
+
| Administrative/File Review
| Friction Reducer
+
| No Violations Noted
| Proprietary
+
| On 9/11/17 an administrative inspection related to the Bovard Dorothy well site was conducted in response to complaint 325615.  The following was found:
| FracTech
+
 
 +
>>Sample results for water chemistry and bacteria load were analyzed.
 
|-
 
|-
 +
| 2684682
 +
| Primary Facility
 +
| 2018-01-22
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Well drilled and equipped for production. Well tag present. Well apparatus,brine tanks and gas production units appear to be in sound condition.  No observation of accelerated erosion or sedimentation observed in relation to the well pad or access road.
 
|-
 
|-
| 4e-05
+
| 2728979
| Polyglycol
+
| Primary Facility
| 0.1
+
| 2018-05-11
| FRW-300
+
| Routine/Complete Inspection
| Friction Reducer
+
| No Violations Noted
| 25322-68-3
+
| Multi-well pad. At the time of this inspection, all 8 wells on this pad are drilled and appear equipped for production.
| FracTech
+
 
 +
The ESCGP-2 for this location was terminated on 1/26/2018.
 
|-
 
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 
|-
 
|-
| 0.01223
+
|}-->
| Aliphatic Hydrocarbon
+
<!--==== Penalties Applied ====
| 30.0
+
{| class="wikitable sortable" width="95%"
| FRW-300
+
!scope="col" | Violation ID
| Friction Reducer
+
!scope="col" | Penalty ID
| Proprietary
+
!scope="col" | Penalty Code
| FracTech
+
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 
|-
 
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|-
| 0.00204
+
| 1
| Oxyalkylated Polymer
+
| 04/11/2013
| 5.0
+
| 04/20/2013
| FRW-300
+
| style="text-align: right;" | 6749
| Friction Reducer
+
| style="text-align: right;" | 5,160,520.0
| Proprietary
+
| style="text-align: right;" |  
| FracTech
 
 
|-
 
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 0.02286
+
|- valign="top"
| Water
+
| rowspan="44"| 1
| 60.0
+
| rowspan="8"| NE100
| FRW-300
+
| rowspan="8"| FracTech
| Friction Reducer
+
| rowspan="8"| Non-Emulsifier
| 7732-18-5
+
| 2-Butoxyethanol
| FracTech
+
| 111-76-2
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00003000
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Dodecylbenzenesulfonic Acid
 +
| 27176-87-0
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00041
+
| Unsulphonated Matter
| Ammonium Thiocynate
+
| Proprietary
| 1.0
+
| style="text-align: right;" | 0.028
| FRW-300
+
| style="text-align: right;" | 0.00000008
| Friction Reducer
+
| style="text-align: right;" | 0
| 1762-95-4
 
| FracTech
 
|-
 
 
|-
 
|-
| 4.25e-08
 
 
| Sulfuric Acid
 
| Sulfuric Acid
| 0.014
 
| NE100
 
| Non-Emulsifier
 
 
| 7664-93-9
 
| 7664-93-9
| FracTech
+
| style="text-align: right;" | 0.014
|-
+
| style="text-align: right;" | 0.00000004
|-
+
| style="text-align: right;" | 0
| 4.2e-09
 
| Sulfur Dioxide
 
| 0.0014
 
| NE100
 
| Non-Emulsifier
 
| 7446-09-5
 
| FracTech
 
 
|-
 
|-
|-
 
| 2e-05
 
 
| 2-Propanol
 
| 2-Propanol
| 10.0
 
| NE100
 
| Non-Emulsifier
 
 
| 67-63-0
 
| 67-63-0
| FracTech
+
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Benzene, C10-16 Alkyl Derivatives
 +
| 68648-87-3
 +
| style="text-align: right;" | 0.042
 +
| style="text-align: right;" | 0.00000013
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 3e-05
+
| Sulfur Dioxide
| 2-Butoxyethanol
+
| 7446-09-5
| 10.0
+
| style="text-align: right;" | 0.0014
| NE100
+
| style="text-align: right;" | 0.00000000
| Non-Emulsifier
+
| style="text-align: right;" | 0
| 111-76-2
 
| FracTech
 
 
|-
 
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 90
 +
| style="text-align: right;" | 0.00028
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 8.5e-08
+
|- valign="top"
| Unsulphonated Matter
+
| rowspan="12"| Cl-150
| 0.028
+
| rowspan="12"| FracTech
| NE100
+
| rowspan="12"| Corrosion Inhibitor
| Non-Emulsifier
+
| Aklylene Oxide Block Polymer
 
| Proprietary
 
| Proprietary
| FracTech
+
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00006000
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Fatty Acid Salt
 +
| Proprietary
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00000061
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2e-05
+
| Dimethylformamide
| Dodecylbenzenesulfonic Acid
+
| 68-12-2
| 5.0
+
| style="text-align: right;" | 10
| NE100
+
| style="text-align: right;" | 0.00006000
| Non-Emulsifier
+
| style="text-align: right;" | 0
| 27176-87-0
 
| FracTech
 
 
|-
 
|-
|-
 
| 0.00028
 
 
| Water
 
| Water
| 90.0
 
| NE100
 
| Non-Emulsifier
 
 
| 7732-18-5
 
| 7732-18-5
| FracTech
+
| style="text-align: right;" | 5
|-
+
| style="text-align: right;" | 0.00003000
|-
+
| style="text-align: right;" | 0
| 0.00485
 
| Glutaraldehyde
 
| 60.0
 
| MC B-8650
 
| Antibacterial Agent
 
| 111-30-8
 
| Multichem
 
|-
 
 
|-
 
|-
| 0.00214
 
 
| Ethylene Glycol
 
| Ethylene Glycol
| 5.0
 
| FRW-300
 
| Friction Reducer
 
 
| 107-21-1
 
| 107-21-1
| FracTech
+
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00018
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| Organic Amine Resin Salt
| 6e-05
 
| Aklylene Oxide Block Polymer
 
| 10.0
 
| Cl-150
 
| Corrosion Inhibitor
 
 
| Proprietary
 
| Proprietary
| FracTech
+
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00018
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| Aliphatic Alcohol
| 6.07e-07
 
| Fatty Acid
 
| 0.1
 
| Cl-150
 
| Corrosion Inhibitor
 
 
| Proprietary
 
| Proprietary
| FracTech
+
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00000061
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00018
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 6.07e-07
+
| Quarternary Ammonium Compound
| Aliphatic Alcohol
 
| 0.1
 
| Cl-150
 
| Corrosion Inhibitor
 
 
| Proprietary
 
| Proprietary
| FracTech
+
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00006000
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Diethylene Glycol
 +
| 111-46-6
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.00001000
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 3e-05
+
| Aromatic Adehyde
| Water
 
| 5.0
 
| Cl-150
 
| Corrosion Inhibitor
 
| 7732-18-5
 
| FracTech
 
|-
 
|-
 
| 6.07e-07
 
| Fatty Acid Salt
 
| 0.1
 
| Cl-150
 
| Corrosion Inhibitor
 
 
| Proprietary
 
| Proprietary
| FracTech
+
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00006000
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| Fatty Acid
| 0.01709
 
| Non-hazardous Solvent Package
 
| 50.0
 
| MC-B-8520
 
| MultiChem
 
 
| Proprietary
 
| Proprietary
| MC-B-8650
+
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00000061
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="10"| FRW-300
 +
| rowspan="10"| FracTech
 +
| rowspan="10"| Friction Reducer
 +
| Ammonium Thiocynate
 +
| 1762-95-4
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.00041
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.02395
 
 
| Water
 
| Water
| 75.0
 
| MC-B-8520
 
| MultiChem
 
 
| 7732-18-5
 
| 7732-18-5
| MC-B-8650
+
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.02286
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Oxyalkylated Alcohol
 +
| Proprietary
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00204
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 9e-05
+
| Polyglycol
| Methanol
+
| 25322-68-3
| 0.25
+
| style="text-align: right;" | 0.1
| MC-B-8520
+
| style="text-align: right;" | 0.00004000
| MultiChem
+
| style="text-align: right;" | 0
| 67-56-1
 
| MC-B-8650
 
 
|-
 
|-
 +
| Sodium Chloride
 +
| 7647-14-5
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00204
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00342
+
| Aliphatic Hydrocarbon
| Neutralized Polymer
 
| 10.0
 
| MC-B-8520
 
| MultiChem
 
 
| Proprietary
 
| Proprietary
| MC-B-8650
+
| style="text-align: right;" | 30
|-
+
| style="text-align: right;" | 0.01223
|-
+
| style="text-align: right;" | 0
| 88.6955
 
| H2O
 
| 100.0
 
| Water
 
| Carrier
 
| 7732-18-5
 
| Range Resources
 
 
|-
 
|-
 +
| Oxyalkylated Polymer
 +
| Proprietary
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00204
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00018
+
| Anionic Polymer
| Organic Amine Resin Salt
 
| 30.0
 
| Cl-150
 
| Corrosion Inhibitor
 
 
| Proprietary
 
| Proprietary
| FracTech
+
| style="text-align: right;" | 30
|-
+
| style="text-align: right;" | 0.01223
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00018
 
 
| Ethylene Glycol
 
| Ethylene Glycol
| 30.0
 
| Cl-150
 
| Corrosion Inhibitor
 
 
| 107-21-1
 
| 107-21-1
| FracTech
+
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00214
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| Polyol Ester
| 6e-05
 
| Quarternary Ammonium Compound
 
| 10.0
 
| Cl-150
 
| Corrosion Inhibitor
 
 
| Proprietary
 
| Proprietary
| FracTech
+
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00204
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| MC B-8650
 +
| rowspan="1"| Multichem
 +
| rowspan="1"| Antibacterial Agent
 +
| Glutaraldehyde
 +
| 111-30-8
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00485
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 6e-05
+
|- valign="top"
| Aromatic Adehyde
+
| rowspan="0"| 37% HCL
| 10.0
+
| rowspan="0"| FracTech
| Cl-150
+
| rowspan="0"| Cleans Perforations
| Corrosion Inhibitor
+
|- valign="top"
| Proprietary
+
| rowspan="2"| 37% HCL
| FracTech
+
| rowspan="2"| FracTech
 +
| rowspan="2"| Cleans Perforation
 +
| HCL
 +
| 7647-01-0
 +
| style="text-align: right;" | 37
 +
| style="text-align: right;" | 0.0245
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 63
 +
| style="text-align: right;" | 0.04171
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 6e-05
+
|- valign="top"
| Dimethylformamide
+
| rowspan="2"| FE100L
| 10.0
+
| rowspan="2"| FracTech
| Cl-150
+
| rowspan="2"| Iron Chelator
| Corrosion Inhibitor
+
| Citric Acid
| 68-12-2
+
| 77-92-9
| FracTech
+
| style="text-align: right;" | 55
 +
| style="text-align: right;" | 0.00084
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00055
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00018
+
|- valign="top"
| Isopropanol
+
| rowspan="4"| MC-B-8520, MC-B-8650
| 30.0
+
| rowspan="4"| MultiChem
| Cl-150
+
| rowspan="4"| Scale Inhibitor & Antibacterial Agent
| Corrosion Inhibitor
+
| Non-hazardous Solvent Package
| 67-63-0
+
| Proprietary
| FracTech
+
| style="text-align: right;" | 50
 +
| style="text-align: right;" | 0.01709
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Neutralized Polymer
 +
| Proprietary
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00342
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 1e-05
+
| Water
| Diethylene Glycol
+
| 7732-18-5
| 1.0
+
| style="text-align: right;" | 75
| Cl-150
+
| style="text-align: right;" | 0.02395
| Corrosion Inhibitor
+
| style="text-align: right;" | 0
| 111-46-6
 
| FracTech
 
 
|-
 
|-
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 0.25
 +
| style="text-align: right;" | 0.00009000
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00055
+
|- valign="top"
| Water
+
| rowspan="1"| Water
| 60.0
+
| rowspan="1"| Range Resources
| FE100L
+
| rowspan="1"| Carrier
| Iron Chelator
+
| H2O
 
| 7732-18-5
 
| 7732-18-5
| FracTech
+
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 88.6955
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand
 +
| rowspan="1"| Range Resources
 +
| rowspan="1"| Proppant
 +
| Crystalline Silica
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 11.1634
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0245
+
|- valign="top"
| HCL
+
| rowspan="3"| MC B-8520
| 37.0
+
| rowspan="3"| Multichem
| 37% HCL
+
| rowspan="3"| Antibacterial Agent
| Cleans Perforation
+
| 2-Amino-2-methyl-1-propanol
| 7647-01-0
+
| 124-68-5
| FracTech
+
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.00017
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 3,4,4-Trimethyloxazolodine
 +
| 75673-43-7
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.0009
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.04171
+
| 4,4-Dimethyloxazolidine
| Water
+
| 51200-87-4
| 63.0
+
| style="text-align: right;" | 100
| 37% HCL
+
| style="text-align: right;" | 0.0183
| Cleans Perforations
+
| style="text-align: right;" | 0
| 7732-18-5
 
| FracTech
 
 
|-
 
|-
 
|}
 
|}
For data sources see<ref>{{cite web | title = FracFocus Chemical Disclosure Registry |publisher = [http://www.fracfocusdata.org/DisclosureSearch/]| date = 2015-08-10 | url = http://wellwiki.org/wiki/Well_Chemicals_Data_Sources | accessdate = 2015-08-10 }}</ref>
+
For data sources see<ref>{{cite web
== References ==
+
| title =FracFocus Fracking Chemicals Database
{{reflist}}
+
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 19:01, 12 July 2019

Well Details

Well ID: 37-003-22233
Loading map...
Country: United States
State: Pennsylvania
County: Allegheny
Municipality: Fawn Township
Operator Name: RANGE RESOURCES APPALACHIA LLC
Well Pad ID: 146710
Farm/Lease Name: BOVARD DOROTHY UNIT 8H
License Status: Active
Spud Date: 10/30/2012
Permit Date: 8/16/2012
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.634542
Longitude: -79.753625

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 RANGE RESOURCES APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 RANGE RESOURCES APPALACHIA LLC 1,315,796.70 235 0.00 0 0.00 0
2014 RANGE RESOURCES APPALACHIA LLC 916,174.23 320 0.00 0 0.00 0
2015 RANGE RESOURCES APPALACHIA LLC 702,748.96 365 0.00 0 0.00 0
2016 RANGE RESOURCES APPALACHIA LLC 512,852.76 356 0.00 0 0.00 0
2017 RANGE RESOURCES APPALACHIA LLC 407,743.91 365 0.00 0 0.00 0
2018 RANGE RESOURCES APPALACHIA LLC 342,376.46 314 0.00 0 0.00 0
2019 RANGE RESOURCES APPALACHIA LLC 84,299.10 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-2 Drill Cuttings (in Tons) 542.82 Tons LANDFILL 100434
2013-1 Drill Cuttings (in Tons) 262.16 Tons LANDFILL 100172
2013-1 Drill Cuttings (in Tons) 174.29 Tons LANDFILL 100280
2013-1 Drilling Fluid Waste (in Barrels) 1,619.52 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Fracing Fluid Waste (in Barrels) 11,111.07 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Fracturing Fluid Waste (in Tons) 21.19 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2013-1 Produced Fluid (in Barrels) 8,031.83 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Produced Fluid (in Barrels) 5,724.64 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 202.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2014-1 Produced Fluid (in Barrels) 1,889.76 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 4,807.52 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 3,336.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2015-1 Produced Fluid (in Barrels) 3,111.62 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 945.68 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2015-2 Produced Fluid (in Barrels) 112.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2015-2 Produced Fluid (in Barrels) 1,436.25 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Fracturing Fluid Waste (in Barrels) RWC 805 8.04 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016-1 Produced Fluid (in Barrels) RWC 802 154.70 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016-1 Produced Fluid (in Barrels) RWC 802 137.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2016-1 Produced Fluid (in Barrels) RWC 802 1,317.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 437.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016-2 Produced Fluid (in Barrels) RWC 802 187.74 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2016-2 Produced Fluid (in Barrels) RWC 802 840.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Other Oil & Gas Wastes (in Barrels) RWC 899 7.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-01 Produced Fluid (in Barrels) RWC 802 24.88 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-01 Produced Fluid (in Barrels) RWC 802 15.25 Bbl REUSE (AT WELL PAD)
2017-02 Other Oil & Gas Wastes (in Barrels) RWC 899 1.01 Bbl REUSE (AT WELL PAD)
2017-02 Produced Fluid (in Barrels) RWC 802 14.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-02 Produced Fluid (in Barrels) RWC 802 13.99 Bbl REUSE (AT WELL PAD)
2017-03 Other Oil & Gas Wastes (in Barrels) RWC 899 3.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-03 Produced Fluid (in Barrels) RWC 802 11.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-03 Produced Fluid (in Barrels) RWC 802 28.18 Bbl REUSE (AT WELL PAD)
2017-04 Other Oil & Gas Wastes (in Barrels) RWC 899 1.89 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 29.95 Bbl REUSE (AT WELL PAD)
2017-05 Other Oil & Gas Wastes (in Barrels) RWC 899 6.41 Bbl REUSE (AT WELL PAD)
2017-05 Produced Fluid (in Barrels) RWC 802 24.40 Bbl REUSE (AT WELL PAD)
2017-06 Other Oil & Gas Wastes (in Barrels) RWC 899 1.25 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 14.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-06 Produced Fluid (in Barrels) RWC 802 14.38 Bbl REUSE (AT WELL PAD)
2017-07 Other Oil & Gas Wastes (in Barrels) RWC 899 4.21 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 15.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017-07 Produced Fluid (in Barrels) RWC 802 19.94 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 15.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-08 Produced Fluid (in Barrels) RWC 802 43.38 Bbl REUSE (AT WELL PAD)
2017-09 Other Oil & Gas Wastes (in Barrels) RWC 899 2.50 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 139.99 Bbl REUSE (AT WELL PAD)
2017-10 Other Oil & Gas Wastes (in Barrels) RWC 899 1.65 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 15.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-10 Produced Fluid (in Barrels) RWC 802 15.09 Bbl REUSE (AT WELL PAD)
2017-11 Other Oil & Gas Wastes (in Barrels) RWC 899 1.64 Bbl REUSE (AT WELL PAD)
2017-11 Produced Fluid (in Barrels) RWC 802 72.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-11 Produced Fluid (in Barrels) RWC 802 29.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-11 Produced Fluid (in Barrels) RWC 802 14.63 Bbl REUSE (AT WELL PAD)
2017-12 Produced Fluid (in Barrels) RWC 802 43.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-12 Produced Fluid (in Barrels) RWC 802 67.65 Bbl REUSE (AT WELL PAD)
2018-01 Produced Fluid (in Barrels) RWC 802 13.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-01 Produced Fluid (in Barrels) RWC 802 71.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018-01 Produced Fluid (in Barrels) RWC 802 27.62 Bbl REUSE (AT WELL PAD)
2018-02 Other Oil & Gas Wastes (in Barrels) RWC 899 1.49 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 13.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-02 Produced Fluid (in Barrels) RWC 802 40.90 Bbl REUSE (AT WELL PAD)
2018-03 Produced Fluid (in Barrels) RWC 802 15.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-03 Produced Fluid (in Barrels) RWC 802 42.53 Bbl REUSE (AT WELL PAD)
2018-04 Produced Fluid (in Barrels) RWC 802 27.43 Bbl REUSE (AT WELL PAD)
2018-05 Produced Fluid (in Barrels) RWC 802 27.77 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-05 Produced Fluid (in Barrels) RWC 802 13.78 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 71.15 Bbl REUSE (AT WELL PAD)
2018-07 Other Oil & Gas Wastes (in Barrels) RWC 899 6.85 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-07 Produced Fluid (in Barrels) RWC 802 13.99 Bbl REUSE (AT WELL PAD)
2018-08 Other Oil & Gas Wastes (in Barrels) RWC 899 13.75 Bbl REUSE (AT WELL PAD)
2018-08 Produced Fluid (in Barrels) RWC 802 13.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-08 Produced Fluid (in Barrels) RWC 802 14.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018-08 Produced Fluid (in Barrels) RWC 802 13.69 Bbl REUSE (AT WELL PAD)
2018-09 Other Oil & Gas Wastes (in Barrels) RWC 899 1.25 Bbl REUSE (AT WELL PAD)
2018-09 Produced Fluid (in Barrels) RWC 802 9.48 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 13.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW030
2018-10 Produced Fluid (in Barrels) RWC 802 13.75 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 14.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW030
2018-11 Produced Fluid (in Barrels) RWC 802 13.03 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 14.24 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW030
2018-12 Produced Fluid (in Barrels) RWC 802 27.61 Bbl REUSE (AT WELL PAD)
2019-01 Produced Fluid (in Barrels) RWC 802 41.22 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 27.38 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 81.70 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2106136 Primary Facility 10/10/2012 Routine/Complete Inspection No Violations Noted John Ley Water Quality Specialist SWRO was on site to conduct a preoperational inspection. The site sign was in place and properly displayed the permits. The site E&S controls and BMP's were well constructed and in good shape. The access road was constructed according to plan and E&S controls had been added to the road. The well pad was still under construction and was almost complete. The hillsides were being hydroseeded during the inspection to stabilize any bare ground.
2116686 Primary Facility 11/05/2012 Drilling/Alteration No Violations Noted CONDUCTOR IS SET. FALCON 22 ONTHE PAD. SITE, E&S, AND ACCESS, OK.
2118835 Primary Facility 11/13/2012 Drilling/Alteration No Violations Noted
2118899 Primary Facility 11/27/2012 Drilling/Alteration No Violations Noted TOP HOLE COMPLETE AT 5560'. A BIG RIG WILL FINISH.
2121284 Primary Facility 12/04/2012 Drilling/Alteration No Violations Noted TOP HOLE TD AT 5,560'. SITE IS OK.
2122998 Primary Facility 12/11/2012 Routine/Complete Inspection No Violations Noted John Ley Water Quality Specialist SWRO was on site to conduct a routine inspection. The site sign was in place and properly displayed the permits. The site E&S controls and BMP's were well constructed and in good shape. The access road was constructed according to plan and E&S controls were working properly. The well was drilled and being cemented. The gathering line for the site was being constructed at the far side. The BMP's were in place and hillsides in this area were temporarily stabilized.
2124778 Primary Facility 12/13/2012 Drilling/Alteration No Violations Noted TOP HOLE COMPLETE. FALCON 22 HAS LEFT THE SITE.
2130108 Primary Facility 01/14/2013 Routine/Complete Inspection No Violations Noted John Ley WQS, SWRO was on site to conduct a routine inspection. At the time of this inspection, the well sign, E&S plan, and the PPC plan were onsite. The site was gated for security. The wells were being drilled. The ground around the site was snow covered but there did not appear to be any accelerated erosion or sedimentation issues.
2131133 Primary Facility 01/07/2013 Drilling/Alteration No Violations Noted TOP HOLE COMPLETE. THE WELL IS COVERD WITH A STEEL PLATE.
2131273 Primary Facility 01/15/2013 Drilling/Alteration No Violations Noted TOP HOLE COMPLETE. RIG ON THE PAD WILL FINISH THE WELL.
2134530 Primary Facility 01/28/2013 Drilling/Alteration No Violations Noted TOP HOLE DRILLING COMPLETE. WELL WILL BE FINISHED NEXT ON THIS PAD.
2143048 Primary Facility 02/07/2013 Drilling/Alteration No Violations Noted DRILLING HORIZONTAL LEG AT 9'538'. SITE IS GOOD.
2156427 Primary Facility 04/10/2013 Drilling/Alteration No Violations Noted WELL IS SET UP FOR FRACING.
2165004 Primary Facility 04/24/2013 Drilling/Alteration No Violations Noted WELL IS FRACED AND BEING PREPARED FOR FLOWBACK. THE SITE IS OK.
2172748 Primary Facility 05/28/2013 Drilling/Alteration No Violations Noted WELL IS PRODUCING. SITE IN GOOD CONDITION.
2173269 Primary Facility 05/20/2013 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with the Bovard Pad (site 750439, inspection record 2173221). Site appeared stabilized; no erosion or sedimentation issues were evident.
2187624 Primary Facility 07/11/2013 Drilling/Alteration No Violations Noted WELL IS COMPLETE. ALL EQUIPTMENT IS HOOKED UP. ACCESS IS LOCKED.
2196173 Primary Facility 08/13/2013 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with the Bovard Pad (site 750439, inspection record 2196159). Area surrounding well pad was mostly vegetated with some unvegetated patches. Water in containment around brine tanks was clear with no sheen visible. Site restoration has been extended until November 9, 2015.
2231277 Primary Facility 12/19/2013 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with the Bovard Well Site (site 750439, inspection record 2231273). Site was snow covered at time of inspection. No erosion or sedimentation issues were evident. Production fluids were contained. This site has a restoration extension until November 9. 2015.
2261726 Primary Facility 04/11/2014 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with the Bovard Well Site (site 750439, inspection record 2261697). Well was drilled and equipped for production. Equipment was on site excavating cellars for additional wells. No erosion or sedimentation issues were evident. Production fluids were contained. This site has a restoration extension until November 9. 2015.
2267348 Primary Facility 04/30/2014 Routine/Complete Inspection No Violations Noted This well was inspected concurrently with the Bovard Well Site (site 750439, inspection record 2266776). This well appears equipped for production. Drill rig was on site for well 2H. No leaks of production fluid were evident. Incipient erosion channel was noted off southern end of pad inside LOD near stake for pipeline. Fabric was drooping on silt fence/super silt fence in two areas and should be mended. This site has a restoration extension until November 9. 2015.
2289894 Primary Facility 07/03/2014 Routine/Complete Inspection No Violations Noted THIS WELL IS COMPLETE AND PRODUCING. THE WELL IS PROTECTED BY A STEEL STRUCTURE AS THE NEW WELLS ARE DRILLED.
2309990 Primary Facility 10/03/2014 Routine/Complete Inspection No Violations Noted Precision Drilling rig 181SL was on site engaged in drillling operations. Vegetative growth between soil pile and pad was sparse. Section of super silt fence partially knocked down near pipeline right of way. No spills of fluids were noted.
2400642 Primary Facility 08/07/2015 Routine/Complete Inspection No Violations Noted On 8/7/15, I inspected the Bovard Dorothy site as a routine inspection and made the following observations:
2410118 Primary Facility 09/14/2015 Routine/Complete Inspection No Violations Noted
2410120 Primary Facility 09/14/2015 Routine/Complete Inspection No Violations Noted THIS IS A WELL MAINTAINED GAS WELL.
2461553 Primary Facility 2016-02-25 Routine/Complete Inspection No Violations Noted THIS WELL AND PRODUCTION EQUIPTMENT HAVE BEEN WELL MAINTAINED.

THE PAD AND ACCESS ARE IN GOOD CONDITION.

2504533 Primary Facility 2016-04-07 Routine/Partial Inspection No Violations Noted On 4/7/16, I performed a routine partial site inspection at the Dorothy Bovard site in response to a request from the operator and met with Range Resources representative Erica Taylor to review requested alteration to the shape of the pad post restoration. The change was approved as a redline change as it did not appear to significantly change flow around the site and decreased impervious surface area slightly.
2566366 Primary Facility 2016-11-16 Complaint Inspection No Violations Noted On 11/16/16, I performed a complaint inspection related to the Bovard site and made the following observations:

•The complainant reported that beginning in late September 2016 their well began producing gray water. Within a few days the water changed to black with intermittent gray at which time the complainant called their well service company to inspect with inconclusive results. At this time the floss filter was reported to have begun clogging regularly and a rotten egg odor was noted. •The complainant reported being in residence for 46-48 years. The well bore is located roughly 10 feet from the house and had a secure cap elevated 6” off of the ground at the time of inspection. The complainant reported that the well was drilled to 240 feet deep in 1988 and has a poly case to 220 feet. The well was reported to have had prior issues with sediment. •Samples were taken from the well for 946 and bacteriological analysis before treatment and after a ten-minute flush. •Inspection of the well site found no i

2571032 Primary Facility 2017-01-13 Administrative/File Review No Violations Noted On 1/13/17, I performed an Admin inspection related to the Bovard Dorothy site in response to complaint 323595 and made the following observations:

•Review of lab results for samples taken 11/16/17 as well as other situational information and found that, while water chemistry parameters were high in multiple instances, oil and gas impact was not conclusively indicated.

2627013 Primary Facility 2017-03-27 Complaint Inspection No Violations Noted On 3/27/2017 a COMPL inspection of the Bovard well and an associated site was completed in response to complaint 325615. The following was observed:

>>E&S controls in multiple locations around the site were observed to be unnecessary and/or in poor repair. All controls should be removed or maintained as appropriate.

>>No evidence of spill or other surface contamination was noted in relation to possible water supply impact.

>>In response to reported bacterial contamination and off taste of the complainants drinking water samples were collected for SAC 946 and bacteriological analysis.

>>The distance from the water supply to the nearest applicable oil & gas activity is roughly 4100 feet. No direct impact from the site was observed.

>>No evidence was observed at the time of inspection to indicate overt surface water impact. The water well head was found to be in good condition.

2657248 Primary Facility 2017-11-06 Routine/Complete Inspection No Violations Noted Well drilled and equipped for production. Well tag present. Well apparatus and brine tanks appear to be in sound condition. No accelerated erosion or sedimentation observed on well site or access road.
2671054 Primary Facility 2017-09-11 Administrative/File Review No Violations Noted On 9/11/17 an administrative inspection related to the Bovard Dorothy well site was conducted in response to complaint 325615. The following was found:

>>Sample results for water chemistry and bacteria load were analyzed.

2684682 Primary Facility 2018-01-22 Routine/Complete Inspection No Violations Noted Well drilled and equipped for production. Well tag present. Well apparatus,brine tanks and gas production units appear to be in sound condition. No observation of accelerated erosion or sedimentation observed in relation to the well pad or access road.
2728979 Primary Facility 2018-05-11 Routine/Complete Inspection No Violations Noted Multi-well pad. At the time of this inspection, all 8 wells on this pad are drilled and appear equipped for production.

The ESCGP-2 for this location was terminated on 1/26/2018.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 04/11/2013 04/20/2013 6749 5,160,520.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 NE100 FracTech Non-Emulsifier 2-Butoxyethanol 111-76-2 10 0.00003000 0
Dodecylbenzenesulfonic Acid 27176-87-0 5 0.00002000 0
Unsulphonated Matter Proprietary 0.028 0.00000008 0
Sulfuric Acid 7664-93-9 0.014 0.00000004 0
2-Propanol 67-63-0 10 0.00002000 0
Benzene, C10-16 Alkyl Derivatives 68648-87-3 0.042 0.00000013 0
Sulfur Dioxide 7446-09-5 0.0014 0.00000000 0
Water 7732-18-5 90 0.00028 0
Cl-150 FracTech Corrosion Inhibitor Aklylene Oxide Block Polymer Proprietary 10 0.00006000 0
Fatty Acid Salt Proprietary 0.1 0.00000061 0
Dimethylformamide 68-12-2 10 0.00006000 0
Water 7732-18-5 5 0.00003000 0
Ethylene Glycol 107-21-1 30 0.00018 0
Organic Amine Resin Salt Proprietary 30 0.00018 0
Aliphatic Alcohol Proprietary 0.1 0.00000061 0
Isopropanol 67-63-0 30 0.00018 0
Quarternary Ammonium Compound Proprietary 10 0.00006000 0
Diethylene Glycol 111-46-6 1 0.00001000 0
Aromatic Adehyde Proprietary 10 0.00006000 0
Fatty Acid Proprietary 0.1 0.00000061 0
FRW-300 FracTech Friction Reducer Ammonium Thiocynate 1762-95-4 1 0.00041 0
Water 7732-18-5 60 0.02286 0
Oxyalkylated Alcohol Proprietary 5 0.00204 0
Polyglycol 25322-68-3 0.1 0.00004000 0
Sodium Chloride 7647-14-5 5 0.00204 0
Aliphatic Hydrocarbon Proprietary 30 0.01223 0
Oxyalkylated Polymer Proprietary 5 0.00204 0
Anionic Polymer Proprietary 30 0.01223 0
Ethylene Glycol 107-21-1 5 0.00214 0
Polyol Ester Proprietary 5 0.00204 0
MC B-8650 Multichem Antibacterial Agent Glutaraldehyde 111-30-8 60 0.00485 0
37% HCL FracTech Cleans Perforations
37% HCL FracTech Cleans Perforation HCL 7647-01-0 37 0.0245 0
Water 7732-18-5 63 0.04171 0
FE100L FracTech Iron Chelator Citric Acid 77-92-9 55 0.00084 0
Water 7732-18-5 60 0.00055 0
MC-B-8520, MC-B-8650 MultiChem Scale Inhibitor & Antibacterial Agent Non-hazardous Solvent Package Proprietary 50 0.01709 0
Neutralized Polymer Proprietary 10 0.00342 0
Water 7732-18-5 75 0.02395 0
Methanol 67-56-1 0.25 0.00009000 0
Water Range Resources Carrier H2O 7732-18-5 100 88.6955 0
Sand Range Resources Proppant Crystalline Silica 14808-60-7 100 11.1634 0
MC B-8520 Multichem Antibacterial Agent 2-Amino-2-methyl-1-propanol 124-68-5 1 0.00017 0
3,4,4-Trimethyloxazolodine 75673-43-7 5 0.0009 0
4,4-Dimethyloxazolidine 51200-87-4 100 0.0183 0

For data sources see[7]

References