X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-033-27198"

m
m
 
(13 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
| Well ID: 033-27198
+
| Well ID: 37-033-27198
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 40.948, -78.464841 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.9480, -78.464842 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Clearfield County, Pennsylvania|Clearfield]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Lawrence Township, Clearfield County, Pennsylvania|Lawrence Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[CHEVRON APPALACHIA LLC|CHEVRON APPALACHIA LLC]]
+
| County: [[Clearfield_County,_Pennsylvania|Clearfield]]
 +
|-
 +
| Municipality: [[Lawrence Township,_Clearfield_County,_Pennsylvania|Lawrence Township]]
 +
|-
 +
| Operator Name: [[LPR ENERGY LLC]]
 +
|-
 +
| Well Pad ID: [[148804]]
 
|-
 
|-
 
| Farm/Lease Name: LYTLE UNIT 6H
 
| Farm/Lease Name: LYTLE UNIT 6H
 
|-
 
|-
| First Permit Date: 2012-05-10
+
| License Status:
 +
|-
 +
| Spud Date:
 +
|-
 +
| Permit Date: 2012-05-10
 +
|-
 +
| Well Type: GAS
 +
|-
 +
| Unconventional Well: Y
 +
|-
 +
| Configuration: Horizontal Well
 +
|-
 +
| Conservation: Yes
 +
|-
 +
| Latitude: 40.9480
 +
|-
 +
| Longitude: -78.464842
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2012-05-10
 +
| New Permit Application
 +
|-
 +
| 2012-06-20
 +
| Performed Spud Operation
 +
|-
 +
| 2012-10-18
 +
| Drilling Completion
 +
|-
 +
| 2013-06-12
 +
| Perforation
 +
|-
 +
| 2014-02-13
 +
| DEVIATED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2013-06-12
 +
| 2013-06-26
 +
| style="text-align: right;" | 8,045
 +
| style="text-align: right;" | 3,978,090
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="12"| 1
 +
| rowspan="3"| EC 6116a
 +
| rowspan="3"| Nalco
 +
| rowspan="3"| Biocide
 +
| Dibromoacetonitrile
 +
| 3252-43-5
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00128
 +
| style="text-align: right;" | 0
 +
|-
 +
| Polyethylene Glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.01533
 +
| style="text-align: right;" | 0
 +
|-
 +
| 1, 1-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00766
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Unislik ST 50
 +
| rowspan="1"| CESI
 +
| rowspan="1"| Friction Reducer
 +
| Hydrotreated Light Distillite
 +
| 64742-47-8
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.03372
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| GBL
 +
| rowspan="1"| Clearwater
 +
| rowspan="1"| Gel Breaker
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00005000
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| 15% Hcl Acid
 +
| rowspan="1"| Reagent/PPG
 +
| rowspan="1"| Used to open perfs
 +
| Hydrochloric Acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.08587
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Iron Control A
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Iron Control
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00723
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| CMHPG
 +
| rowspan="1"| Ashland
 +
| rowspan="1"| Water Viscosifier
 +
| Carboxymethyl Hydroxporoyl Guar Blend
 +
| 68130-15-4
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.00343
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Scale Inhibitor A
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Scale Inhibitor
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00757
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Proppant
 +
| rowspan="1"| Chevron Applachia, LLC
 +
| rowspan="1"| Proppant
 +
| Crystalline Silica
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 8.68
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Clean Volume
 +
| rowspan="1"| Chevron Applachia, LLC
 +
| rowspan="1"| Carrier/Base Fluid
 +
| H20
 +
| 7732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 91.32
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| ASP 900
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Friction Reducer
 +
| Ammonium Sulfate
 +
| 7783-20-2
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| Last Permit Date: 2012-05-10
+
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Spud Date: 2012-06-20
+
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 121,837.00
 +
| style="text-align: right;" | 155
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Unconventional: Yes
+
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 542,733.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Horizontal: Yes
+
| 2015
 +
| [[LPR ENERGY LLC]]
 +
| style="text-align: right;" | 153,918.00
 +
| style="text-align: right;" | 181
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Producing: Yes
+
| 2016
 +
| [[LPR ENERGY LLC]]
 +
| style="text-align: right;" | 189,267.00
 +
| style="text-align: right;" | 170
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Violations: None
+
| 2017
 +
| [[LPR ENERGY LLC]]
 +
| style="text-align: right;" | 217,297.00
 +
| style="text-align: right;" | 350
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Latitude: 40.948
+
| 2018
 +
| [[LPR ENERGY LLC]]
 +
| style="text-align: right;" | 148,579.00
 +
| style="text-align: right;" | 314
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Longitude: -78.464841
+
| 2019
 +
| [[LPR ENERGY LLC]]
 +
| style="text-align: right;" | 124,285.00
 +
| style="text-align: right;" | 325
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
__TOC__
+
For data sources see<ref>{{cite web
== Well Inspection Data ==
+
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 +
|-
 +
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 60.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 453.13 Tons
 +
| LANDFILL
 +
| 101397
 +
|-
 +
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 835.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW001
 +
|-
 +
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 889.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 980.75 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 +
|-
 +
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 9,336.25 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 1.01 Tons
 +
| LANDFILL
 +
| 100434
 +
|-
 +
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 375.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW001
 +
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 77.50 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 +
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 10.49 Tons
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
| MID074259565
 +
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 55.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-121-23995
 +
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 0.05 Tons
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
| MID0209062814
 +
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 42.50 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 +
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 18.33 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 4,579.84 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 17.55 Tons
 +
| LANDFILL
 +
| 100434
 +
|-
 +
| 2015
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 28.33 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 +
|-
 +
| 2015
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,160.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 50.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 +
|-
 +
| 2016
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 205.66 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123NW011
 +
|-
 +
| 2016
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 30.00 Bbl
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
|
 +
|-
 +
| 2016
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 56.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-24355
 +
|-
 +
| 2017
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 119.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D561BSOM
 +
|-
 +
| 2017
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 29.20 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 +
|-
 +
| 2017
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 177.00 Bbl
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
|
 +
|-
 +
| 2018
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 16.00 Bbl
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
|
 +
|-
 +
| 2018
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 8.10 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-21847
 +
|-
 +
| 2018
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 281.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D561BSOM
 +
|-
 +
| 2019
 +
| [[LPR ENERGY LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 240.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D561BSOM
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
 
| 2085813
 
| 2085813
 +
| Primary Facility
 
| 2012-07-24
 
| 2012-07-24
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2088967
 
| 2088967
 +
| Primary Facility
 
| 2012-08-02
 
| 2012-08-02
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2107489
 
| 2107489
 +
| Primary Facility
 
| 2012-10-02
 
| 2012-10-02
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2109041
 
| 2109041
 +
| Primary Facility
 
| 2012-10-18
 
| 2012-10-18
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2119714
 
| 2119714
 +
| Primary Facility
 
| 2012-11-29
 
| 2012-11-29
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2133749
 
| 2133749
 +
| Primary Facility
 
| 2013-01-28
 
| 2013-01-28
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2138092
 
| 2138092
 +
| Primary Facility
 
| 2013-02-11
 
| 2013-02-11
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2149192
 +
| Primary Facility
 +
| 2013-03-19
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
|}
+
| 2160598
== Production Data ==
+
| Primary Facility
{| class="wikitable sortable" width="95%"
+
| 2013-04-23
!scope="col" | PERIOD
+
| Routine/Complete Inspection
!scope="col" | GAS QUANTITY
+
| No Violations Noted
!scope="col" | GAS PRODUCTION DAYS
+
|  
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2012-2
+
| 2177512
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2013-06-24
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2187026
 +
| Primary Facility
 +
| 2013-07-29
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 
|-
 
|-
| 2012-1
+
| 2198422
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2013-08-26
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
 
|-
 
|-
|}
+
| 2224938
== Waste Data ==
+
| Primary Facility
{| class="wikitable sortable" width="95%"
+
| 2013-11-26
!scope="col" | PERIOD
+
| Routine/Complete Inspection
!scope="col" | TYPE
+
| No Violations Noted
!scope="col" | QUANTITY
+
|  
!scope="col" | UNITS
 
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-2
+
| 2286485
| DRILLING FLUID WASTE
+
| Primary Facility
| style="text-align:right;" | 835.0
+
| 2014-07-02
| Bbl
+
| Routine/Complete Inspection
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| No Violations Noted
| PA0253723
+
|  
| APPALACHIAN WATER SERVICES LLC (RONCO WTP)
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2323547
 +
| Primary Facility
 +
| 2014-11-20
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 
|-
 
|-
| 2012-2
+
| 2398783
| DRILLING FLUID WASTE
+
| Primary Facility
| style="text-align:right;" | 60.0
+
| 2015-07-30
| Bbl
+
| Routine/Complete Inspection
| REUSE OTHER THAN ROAD SPREADING
+
| No Violations Noted
 
|  
 
|  
| REUSE FOR DRILLING OR PLUGGING
+
|-
 +
| 2464085
 +
| Primary Facility
 +
| 2016-03-10
 +
| Site Restoration
 +
| No Violations Noted
 
|  
 
|  
| PA
+
|-
 +
| 2694605
 +
| Primary Facility
 +
| 2018-02-08
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Routine site inspection at LPR Energy's Lytle Unit on February 8, 2018. No one was onsite during my inspection.
 +
 
 +
The site sign with emergency contact information was present and located at the entrance road. The mailbox onsite contains all Chevron's old paperwork, emergency response plan, PPC plan, etc. I recommend updating the PPC Plan and Emergency response plan with LPR's information.
 +
 
 +
There are a total of 6 Marcellus wells spudded on this pad. Each well is labeled with the API/well permit number. Wells (033-26874, 033-27093, 033-27196, 033-27197, and 033-27198) have been TD'ed, stimulated, flowed-back and are in active production status. Well 033-26971 was spudded but not completed and plugged by Chevron, prior to being transferred to LPR Energy.
 +
 
 +
There are a total of 5 GPU's onsite. In addition, there are (4) 400 bbl produced fluids tanks stationed in secondary containment. Water within containment was frozen. No corrosion was observed on the exterior of the produced fluids tanks. The entire pad and s
 +
|-
 +
| 2835852
 +
| Primary Facility
 +
| 2019-02-04
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Routine site inspection at LPR Energy's Lytle Unit on February 4, 2019. No one was onsite during my inspection.
 +
 
 +
There are a total of 6 Marcellus wells spud on this pad. Each well is labeled with the API/well permit number. Wells (033-26874, 033-27093, 033-27196, 033-27197, and 033-27198) have been TD'ed, stimulated, flowed-back and are in active production status. Well 033-26971 was spud but never completed and was plugged by Chevron, prior to being transferred to LPR Energy. (5) GPUs were observed onsite. (4) 400 bbl produced fluids tanks are stationed onsite in secondary containment.
 +
 
 +
No violations noted.
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
==References==
 
==References==
{{Reflist}}
+
<references/>
 
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 16:09, 14 May 2020

Well Details

Well ID: 37-033-27198
Loading map...
Country: United States
State: Pennsylvania
County: Clearfield
Municipality: Lawrence Township
Operator Name: LPR ENERGY LLC
Well Pad ID: 148804
Farm/Lease Name: LYTLE UNIT 6H
License Status:
Spud Date:
Permit Date: 2012-05-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.9480
Longitude: -78.464842

For data sources see[1][2][3]

Well History

Date Event
2012-05-10 New Permit Application
2012-06-20 Performed Spud Operation
2012-10-18 Drilling Completion
2013-06-12 Perforation
2014-02-13 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-06-12 2013-06-26 8,045 3,978,090

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 EC 6116a Nalco Biocide Dibromoacetonitrile 3252-43-5 5 0.00128 0
Polyethylene Glycol 25322-68-3 60 0.01533 0
1, 1-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00766 0
Unislik ST 50 CESI Friction Reducer Hydrotreated Light Distillite 64742-47-8 30 0.03372 0
GBL Clearwater Gel Breaker Ethylene Glycol 107-21-1 60 0.00005000 0
15% Hcl Acid Reagent/PPG Used to open perfs Hydrochloric Acid 7647-01-0 15 0.08587 0
Iron Control A Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00723 0
CMHPG Ashland Water Viscosifier Carboxymethyl Hydroxporoyl Guar Blend 68130-15-4 100 0.00343 0
Scale Inhibitor A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00757 0
Proppant Chevron Applachia, LLC Proppant Crystalline Silica 14808-60-7 100 8.68 0
Clean Volume Chevron Applachia, LLC Carrier/Base Fluid H20 7732-18-5 100 91.32 0
ASP 900 Nalco Friction Reducer Ammonium Sulfate 7783-20-2 30 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 121,837.00 155 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 542,733.00 365 0.00 0 0.00 0
2015 LPR ENERGY LLC 153,918.00 181 0.00 0 0.00 0
2016 LPR ENERGY LLC 189,267.00 170 0.00 0 0.00 0
2017 LPR ENERGY LLC 217,297.00 350 0.00 0 0.00 0
2018 LPR ENERGY LLC 148,579.00 314 0.00 0 0.00 0
2019 LPR ENERGY LLC 124,285.00 325 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 60.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings 453.13 Tons LANDFILL 101397
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 835.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid 889.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 980.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 9,336.25 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 1.01 Tons LANDFILL 100434
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 375.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 77.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 10.49 Tons STORAGE PENDING DISPOSAL OR REUSE MID074259565
2014 CHEVRON APPALACHIA LLC Produced Fluid 55.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 0.05 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2014 CHEVRON APPALACHIA LLC Produced Fluid 42.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 18.33 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 4,579.84 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 17.55 Tons LANDFILL 100434
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste 28.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 CHEVRON APPALACHIA LLC Produced Fluid 1,160.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 LPR ENERGY LLC Produced Fluid 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2016 LPR ENERGY LLC Produced Fluid 205.66 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 LPR ENERGY LLC Produced Fluid 30.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2016 LPR ENERGY LLC Produced Fluid 56.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2017 LPR ENERGY LLC Produced Fluid 119.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2017 LPR ENERGY LLC Produced Fluid 29.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 LPR ENERGY LLC Produced Fluid 177.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2018 LPR ENERGY LLC Produced Fluid 16.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2018 LPR ENERGY LLC Produced Fluid 8.10 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018 LPR ENERGY LLC Produced Fluid 281.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM
2019 LPR ENERGY LLC Produced Fluid 240.00 Bbl INJECTION DISPOSAL WELL PAS2D561BSOM

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2085813 Primary Facility 2012-07-24 Drilling/Alteration No Violations Noted
2088967 Primary Facility 2012-08-02 Routine/Complete Inspection No Violations Noted
2107489 Primary Facility 2012-10-02 Drilling/Alteration No Violations Noted
2109041 Primary Facility 2012-10-18 Routine/Complete Inspection No Violations Noted
2119714 Primary Facility 2012-11-29 Routine/Complete Inspection No Violations Noted
2133749 Primary Facility 2013-01-28 Routine/Complete Inspection No Violations Noted
2138092 Primary Facility 2013-02-11 Routine/Complete Inspection No Violations Noted
2149192 Primary Facility 2013-03-19 Routine/Complete Inspection No Violations Noted
2160598 Primary Facility 2013-04-23 Routine/Complete Inspection No Violations Noted
2177512 Primary Facility 2013-06-24 Routine/Complete Inspection No Violations Noted
2187026 Primary Facility 2013-07-29 Routine/Complete Inspection No Violations Noted
2198422 Primary Facility 2013-08-26 Routine/Complete Inspection No Violations Noted
2224938 Primary Facility 2013-11-26 Routine/Complete Inspection No Violations Noted
2286485 Primary Facility 2014-07-02 Routine/Complete Inspection No Violations Noted
2323547 Primary Facility 2014-11-20 Routine/Complete Inspection No Violations Noted
2398783 Primary Facility 2015-07-30 Routine/Complete Inspection No Violations Noted
2464085 Primary Facility 2016-03-10 Site Restoration No Violations Noted
2694605 Primary Facility 2018-02-08 Routine/Complete Inspection No Violations Noted Routine site inspection at LPR Energy's Lytle Unit on February 8, 2018. No one was onsite during my inspection.

The site sign with emergency contact information was present and located at the entrance road. The mailbox onsite contains all Chevron's old paperwork, emergency response plan, PPC plan, etc. I recommend updating the PPC Plan and Emergency response plan with LPR's information.

There are a total of 6 Marcellus wells spudded on this pad. Each well is labeled with the API/well permit number. Wells (033-26874, 033-27093, 033-27196, 033-27197, and 033-27198) have been TD'ed, stimulated, flowed-back and are in active production status. Well 033-26971 was spudded but not completed and plugged by Chevron, prior to being transferred to LPR Energy.

There are a total of 5 GPU's onsite. In addition, there are (4) 400 bbl produced fluids tanks stationed in secondary containment. Water within containment was frozen. No corrosion was observed on the exterior of the produced fluids tanks. The entire pad and s

2835852 Primary Facility 2019-02-04 Routine/Complete Inspection No Violations Noted Routine site inspection at LPR Energy's Lytle Unit on February 4, 2019. No one was onsite during my inspection.

There are a total of 6 Marcellus wells spud on this pad. Each well is labeled with the API/well permit number. Wells (033-26874, 033-27093, 033-27196, 033-27197, and 033-27198) have been TD'ed, stimulated, flowed-back and are in active production status. Well 033-26971 was spud but never completed and was plugged by Chevron, prior to being transferred to LPR Energy. (5) GPUs were observed onsite. (4) 400 bbl produced fluids tanks are stationed onsite in secondary containment.

No violations noted.

For data sources see[8]

References