37-051-24313

Well Details

Well ID: 37-051-24313
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Redstone Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 147923
Farm/Lease Name: CARDINE UNIT 7H
License Status: Active
Spud Date: 2010-03-29
Permit Date: 2010-01-05
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 39.958559
Longitude: -79.840367

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 ATLAS RESOURCES LLC 657,822.00 285 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 535,784.00 366 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 363,454.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 270,425.00 334 0.00 0 40.00 153
2015 CHEVRON APPALACHIA LLC 221,374.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 182,986.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 170,103.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 153,017.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 36,309.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-S02 Drilling Fluid Waste (in Barrels) 1,685.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2010-S02 Drilling Fluid Waste (in Barrels) 115.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010-S02 Fracing Fluid Waste (in Barrels) 830.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2010-S02 Fracing Fluid Waste (in Barrels) 6,129.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2011-S01 Drilling Fluid Waste (in Barrels) 1,650.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011-S01 Fracing Fluid Waste (in Barrels) 660.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011-S01 Fracing Fluid Waste (in Barrels) 1,420.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2011-S01 Fracing Fluid Waste (in Barrels) 285.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011-S01 Produced Fluid (in Barrels) 1,536.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE
2011-S01 Produced Fluid (in Barrels) 414.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674
2011-S01 Produced Fluid (in Barrels) 880.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2011-S01 Produced Fluid (in Barrels) 85.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-099-23127
2011-S01 Produced Fluid (in Barrels) 990.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011-S01 Produced Fluid (in Barrels) 2,075.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2011-S01 Produced Fluid (in Barrels) 660.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011-S01 Produced Fluid (in Barrels) 550.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011-S01 Produced Fluid (in Barrels) 1,340.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2011-S01 Produced Fluid (in Barrels) 1,606.00 Bbl IDENTIFY METHOD IN COMMENTS 34-167-29359
2011-S02 Fracing Fluid Waste (in Barrels) 240.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011-S02 Produced Fluid (in Barrels) 877.00 Bbl INJECTION DISPOSAL WELL 34-121-2-3995
2011-S02 Produced Fluid (in Barrels) 279.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S01 Produced Fluid (in Barrels) 125.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2012-S01 Produced Fluid (in Barrels) 415.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S02 Produced Fluid (in Barrels) 365.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Produced Fluid (in Barrels) 340.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Produced Fluid (in Barrels) 420.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Produced Fluid (in Barrels) 985.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 40.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014-S02 Produced Fluid (in Barrels) 520.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 210.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 640.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 310.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 367.52 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-S02 Produced Fluid (in Barrels) RWC 802 50.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M04 Produced Fluid (in Barrels) RWC 802 110.00 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 56.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M09 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE (AT WELL PAD)
2017-M11 Produced Fluid (in Barrels) RWC 802 56.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M01 Produced Fluid (in Barrels) RWC 802 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018-M01 Produced Fluid (in Barrels) RWC 802 56.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M04 Produced Fluid (in Barrels) RWC 802 50.00 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 54.00 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M02 Produced Fluid (in Barrels) RWC 802 60.00 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1873507 Primary Facility 2010-03-30 Drilling/Alteration No Violations Noted
1875887 Primary Facility 2010-04-02 Drilling/Alteration No Violations Noted
1889743 Primary Facility 2010-05-27 Routine/Complete Inspection No Violations Noted
1946440 Primary Facility 2011-01-31 Routine/Complete Inspection No Violations Noted
1952055 Primary Facility 2011-02-24 Routine/Complete Inspection No Violations Noted
1963485 Primary Facility 2011-04-05 Routine/Complete Inspection No Violations Noted
2488204 Primary Facility 2016-05-16 Routine/Complete Inspection No Violations Noted
2571602 Primary Facility 2017-03-15 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was covered in light snow but appeared to be well vegetated. There were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[6]

References