37-051-24471

Well Details

Well ID: 37-051-24471
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: North Union Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148680
Farm/Lease Name: KIKTA UNIT 4H
License Status: Active
Spud Date: 2011-10-23
Permit Date: 2011-09-30
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 39.946967
Longitude: -79.743442

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-11-27 2012-11-27 8096.00 3,323,149.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Clean Volume (gals) Carrier/Base Fluid 91.20 100.00
Biocide EC 6116A Nalco Biocide Dibromoacetonitrile 3252-43-5 5.00 0.00116000
Polyethylene glycol 25322-68-3 60.00 0.01
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00696000
Scale Inhibitor A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00690000
Unislik ST 50 CESI Chemical Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
CMHPG Ashland Water Viscosifier Carboxymethylhydroxyporoyl guar blend 100.00 0.00182000
Iron Control A Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00698000
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
GBL Clearwater International Gel Breaker Ethylene glycol 107-21-1 60.00 0.00003000
Proppant (lbs) Proppant 8.80 9.72
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.27

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 539,397.00 306 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 449,905.00 365 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 303,874.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 219,410.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 188,459.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 171,456.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 41,445.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2011-S02 Fracing Fluid Waste (in Barrels) 165.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S01 Drilling Fluid Waste (in Barrels) 1,342.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012-S02 Fracing Fluid Waste (in Barrels) 1,993.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Fracing Fluid Waste (in Barrels) 4,337.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Fracing Fluid Waste (in Barrels) 2,737.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013-S02 Fracing Fluid Waste (in Barrels) 25,705.75 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Fracturing Fluid Waste (in Tons) 54.87 Tons LANDFILL 073 114 654
2013-S02 Produced Fluid (in Barrels) 1,527.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014-S01 Drilling Fluid Waste (in Barrels) 75.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Fracturing Fluid Waste (in Tons) 9.12 Tons STORAGE PENDING DISPOSAL OR REUSE MID074259565
2014-S01 Produced Fluid (in Barrels) 978.75 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014-S01 Produced Fluid (in Barrels) 225.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 584.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 406.25 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 316.25 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 265.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 149.26 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-S02 Produced Fluid (in Barrels) RWC 802 85.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M02 Produced Fluid (in Barrels) RWC 802 81.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M03 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M06 Drilling Fluid Waste (in Barrels) RWC 803 27.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M06 Produced Fluid (in Barrels) RWC 802 27.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M08 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE (AT WELL PAD)
2017-M09 Produced Fluid (in Barrels) RWC 802 28.75 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2017-M12 Produced Fluid (in Barrels) RWC 802 57.75 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M01 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M02 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE (AT WELL PAD)
2018-M02 Produced Fluid (in Barrels) RWC 802 56.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M04 Produced Fluid (in Barrels) RWC 802 53.50 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 28.75 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 52.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M11 Produced Fluid (in Barrels) RWC 802 56.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M01 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 90.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2038525 Primary Facility 2012-01-06 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 332', RUNNING WATER PROTECTION CASING AND CEMENTING TODAY.
2038530 Primary Facility 2012-01-08 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,DRILLING ON AIR @ 1007',RUNNING COAL PROTECTION CASING AND CEMENTING TODAY.
2038538 Primary Facility 2012-01-10 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 1026' TODAY.
2038543 Primary Facility 2012-01-12 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, YOST # 5 DRILLING ON AIR @ 2489',RUNNIIG INTERMEDIATE CASING AND CEMENTING TONIGHT.
2039150 Primary Facility 2012-01-25 Routine/Complete Inspection No Violations Noted The Department was at the above referenced Marcellus Well to conduct an inspection after being notified of stream contamination down gradient of this well site. The Department observed impacts to an unnamed tributary down gradient of this Well. The stream was gray/reddish in color. The Department took samples of the stream and also took samples of the drilling mud on site. The Driller on site said that they were drilling on air until 3:00AM in the morning. Apparently the stream had turned colors the day before on 1/24/12 at approximately 1:30PM. The Driller also said they have casing set at a depth of 2,534 ft. The Department grabbed a sample of the black drill mud to determine who was at fault for the stream contamination. The Department will provide sample results to the Operator. Another company is conducting a HDD bore adjacent to this Marcellus Operation. All parties will receive sample results and will be notified of the Department's final determination to the cause of the stream contamination.
2055038 Primary Facility 2012-03-26 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 325 MOVING ON TO LOCATION THIS WEEK.
2055040 Primary Facility 2012-02-27 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 9 MOVING OFF LOCATION TODAY.
2055042 Primary Facility 2012-02-24 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 7400' TODAY,(TD) SAT. @ 7474' . MUDDING UP AND CAPPING.
2055049 Primary Facility 2012-01-10 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 2489' (TD). RUNNING INTERMEDIATE CASING AND CEMENTING TONIGHT.
2055050 Primary Facility 2012-01-08 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 1007' (TD). RUNNING COAL PROTECTION CASING AND CEMENTING TONIGHT.
2055061 Primary Facility 2012-01-06 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 335' (TD).RUNNING WATER PROTECTION CASING AND CEMENTING TONIGHT.
2065722 Primary Facility 2012-04-10 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON 325 DRILLING ON FLUID ,CHEVRON DECIDED TO PLUG VERTICAL WELL BORE BACK TO 7100'.TWO ATTEMPTS TO DO HORIZONTAL PORTION HAS FAILED. MAJOR FAULT ISSUES.
2065735 Primary Facility 2012-04-20 Routine/Complete Inspection No Violations Noted E&S in place and functioning. Site ID sign in place. Actively drilling 3H well at present time.
2071915 Primary Facility 2012-05-30 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 325 DRILLING ON FLUID @ 11,606' (TD). RUNNING 51/2" PROD. CASING AND CEMENTING TONIGHT 5/27/2012).
2071918 Primary Facility 2012-05-18 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 325 MOVING ON TO KIKTA 4 - H.
2075019 Primary Facility 2012-06-12 Administrative/File Review In Compliance with Policy Operator performed spill clean up and reporting in compliance with current spill policy.
2077308 Primary Facility 2012-06-20 Complaint Inspection No Violations Noted Well area checked as result of nearby complaint. All 4 wells completed, E&S looks ok.
2125520 Primary Facility 2012-12-26 Incident- Response to Accident or Event In Compliance with Policy Operator self reported a 0.25 gallon power steering fluid spill on containment. Operator handled spill incident in compliance with current Departments spill policy.
2147966 Primary Facility 2013-03-14 Routine/Complete Inspection No Violations Noted Site ID sign up and E&S, PPC and permits in box. Flow back work going on, 3 tanks in containment in, 4 heater units in, pipeline connected, E&S in place and functioning. Two pits/impoundments good freeboard, strong smell of frack water from one impoundment. Three sed traps in place. Site stable.
2185051 Primary Facility 2013-07-19 Site Restoration No Violations Noted Site restoration extension requested. Site stable and has good vegetative growth. Extension approved until the new date of 12/5/2014.
2209817 Primary Facility 2013-10-02 Routine/Complete Inspection No Violations Noted Act 9 sign up, permits and plans in box, last pit being removed, wells labeled, no E&S issues.
2273913 Primary Facility 2014-05-22 Routine/Complete Inspection No Violations Noted On 5/22/2014, the Department conducted an inspection of Chevron Appalachia’s Kikta Unit 1, 2, 3, 4H well site in North Union Twp., Fayette County.
2316607 Primary Facility 2014-10-24 Complaint Inspection No Violations Noted 4 wells drilled and producing. Site graded and vegetation started.
2379933 Primary Facility 2015-06-02 Routine/Complete Inspection No Violations Noted
2446487 Primary Facility 2016-02-01 Routine/Complete Inspection No Violations Noted

On 02/01/16 at approximately 1330 hours I conducted a site restoration inspection in response to an NOT submittal by Chevron Appalachia LLC. The Act 9 sign was in place and all required documents were present at the site.

The site was well vegetated and met the requirements of uniform 70% growth. All temporary BMPs had been removed from the site and there was no unnecessary equipment present at the site. The NOT is approved.

2563786 Primary Facility 2017-02-22 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present. The site was well vegetated and there were no signs of erosion observed at the time of inspection. The equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2666275 Primary Facility 2017-11-20 Complaint Inspection No Violations Noted An inspection was conducted in response to a water supply complaint. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition and there were no signs of leaks or spills. There were no violations observed at the time of inspection.
2825639 Primary Facility 2019-01-11 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and tank battery look ok.

For data sources see[7]

References