X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-051-24507"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-051-24507
 
| Well ID: 37-051-24507
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.065575, -79.82488 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.065575, -79.824881 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Fayette County, Pennsylvania|Fayette]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Jefferson Township, Fayette County, Pennsylvania|Jefferson Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Fayette_County,_Pennsylvania|Fayette]]
 +
|-
 +
| Municipality: [[Jefferson Township,_Fayette_County,_Pennsylvania|Jefferson Township]]
 
|-
 
|-
 
| Operator Name: [[CHEVRON APPALACHIA LLC]]
 
| Operator Name: [[CHEVRON APPALACHIA LLC]]
 
|-
 
|-
| Well Pad ID: [[148756|148756]]
+
| Well Pad ID: [[148756]]
 
|-
 
|-
 
| Farm/Lease Name: LESTER UNIT 7H
 
| Farm/Lease Name: LESTER UNIT 7H
 
|-
 
|-
| First Permit Date: 2012-04-11
+
| License Status: Active
|-
 
| Last Permit Date: 2012-04-11
 
 
|-
 
|-
| Spud Date: 2012-04-29
+
| Spud Date: 04/29/2012
 
|-
 
|-
| Unconventional: Yes
+
| Permit Date: 4/11/2012
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Well Status: ACTIVE
+
| Configuration: Horizontal Well
|-
 
| Violations: 0
 
 
|-
 
|-
 
| Latitude: 40.065575
 
| Latitude: 40.065575
 
|-
 
|-
| Longitude: -79.82488
+
| Longitude: -79.824881
|-
 
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2012-1
+
| 2012
| style="text-align:right;" | 0.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 550,055.00
 +
| style="text-align: right;" | 275
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-2
+
| 2014
| style="text-align:right;" | 0.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 839,846.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2015
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 564,893.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2013-1
+
| 2016
| style="text-align:right;" | 11448.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 91.0
+
| style="text-align: right;" | 398,442.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 366
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 321,411.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2013-2
+
| 2018
| style="text-align:right;" | 538607.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 273,355.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| 2019
| 2014-1
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 444113.0
+
| style="text-align: right;" | 62,436.00
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 90
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
|-
 
|-
 
| 2014-2
 
| style="text-align:right;" | 395733.0
 
| style="text-align:right;" | 184.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-02
 
| style="text-align:right;" | 46281.0
 
| style="text-align:right;" | 28.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-01
 
| style="text-align:right;" | 53230.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-03
 
| style="text-align:right;" | 71056.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Waste Type
!scope="col" | QUANTITY
+
!scope="col" | Quantity
!scope="col" | UNITS
+
!scope="col" | Disposal Method
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-1
+
| 2012-S01
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 367.0
+
| style="text-align: right;" | 367.00 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW001
 
| WMGR123SW001
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
|-
 
 
|-
 
|-
| 2012-2
+
| 2012-S02
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 930.56
+
| style="text-align: right;" | 930.56 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 100419
 
| 100419
| ADVANCED DISPOSAL SERVICE CHESTNUT VALLEY LANDFILL
 
| MCCLELLANDTOWN
 
| PA
 
 
|-
 
|-
 +
| 2012-S02
 +
| Drilling Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 350.40 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW001
 
|-
 
|-
| 2012-2
+
| 2012-S02
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 580.0
+
| style="text-align: right;" | 580.00 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR DRILLING OR PLUGGING
+
|-
|  
+
| 2012-S02
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 1,418.20 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2013-S01
 +
| Drilling Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 18.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW001
 
|-
 
|-
| 2012-2
+
| 2013-S01
| DRILLING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 350.4
+
| style="text-align: right;" | 1,490.00 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW001
 
| WMGR123SW001
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2013-S01
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 6,792.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2012-2
+
| 2013-S02
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 2,575.80 Bbl
| Bbl
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 +
|-
 +
| 2013-S02
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 9,555.80 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR DRILLING OR PLUGGING
+
|-
 +
| 2013-S02
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 87.59 Tons
 +
| LANDFILL
 +
| 100592
 +
|-
 +
| 2013-S02
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,217.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2014-S01
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 7.08 Tons
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
| MID074259565
 +
|-
 +
| 2014-S01
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,677.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
|-
+
| 2014-S02
| 2013-1
+
| Fracing Fluid Waste (in Barrels)
| DRILLING FLUID WASTE
+
| style="text-align: right;" | 3.00 Bbl
| style="text-align:right;" | 18.0
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
 
| WMGR123SW001
 
| WMGR123SW001
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2014-S02
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 9.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2013-1
+
| 2014-S02
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 6.0
+
| style="text-align: right;" | 876.00 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR DRILLING OR PLUGGING
+
|-
 +
| 2015-S01
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 533.60 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2015-S02
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 473.40 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2016-S01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 543.40 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2013-1
+
| 2016-S02
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 362.02 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW019
 +
|-
 +
| 2016-S02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 66.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2017-M01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 46.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2017-M02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 69.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2017-M03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 40.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2017-M03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW001
 +
|-
 +
| 2017-M04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 26.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 966.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW001
 
| WMGR123SW001
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2017-M06
 +
| Drilling Fluid Waste (in Barrels) RWC 803
 +
| style="text-align: right;" | 24.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 
|-
 
|-
| 2013-2
+
| 2017-M07
| FLOWBACK FRACTURING SAND
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 87.59
+
| style="text-align: right;" | 22.00 Bbl
| Tons
+
| RESIDUAL WASTE PROCESSING FACILITY
| LANDFILL
+
| WMGR123SW001
| 100592
+
|-
| SOUTH HILLS LANDFILL
+
| 2017-M07
| SOUTH HILLS
+
| Produced Fluid (in Barrels) RWC 802
| PA
+
| style="text-align: right;" | 22.40 Bbl
 +
| REUSE (AT WELL PAD)
 +
|  
 
|-
 
|-
 +
| 2017-M08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 23.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW001
 
|-
 
|-
| 2013-2
+
| 2017-M08
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 9.0
+
| style="text-align: right;" | 22.40 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017-M09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.40 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-M10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.40 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-M11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 26.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 2013-2
+
| 2017-M12
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 2.0
+
| style="text-align: right;" | 42.00 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
|  
| WMGR123SW001
 
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2018-M01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.02 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 
|-
 
|-
| 2013-2
+
| 2018-M01
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 23.00 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-M02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-M03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 43.80 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-M04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 45.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-1
+
| 2018-M05
| FLOWBACK FRACTURING SAND
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 7.08
+
| style="text-align: right;" | 22.00 Bbl
| Tons
+
| RESIDUAL WASTE PROCESSING FACILITY
| STORAGE PENDING DISPOSAL OR REUSE
+
| WMGR123SW005
| MID074259565
 
| US ECOLOGY
 
| DETROIT
 
| MI
 
 
|-
 
|-
 +
| 2018-M05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-1
+
| 2018-M06
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 44.00 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-M07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-M07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 +
| 2018-M08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 45.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 2014-2
+
| 2018-M09
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 9.0
+
| style="text-align: right;" | 42.00 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-M11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 23.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-M11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 42.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 +
| 2018-M12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-2
+
| 2018-M12
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 3.0
+
| style="text-align: right;" | 22.00 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
|  
| WMGR123SW001
 
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2019-M01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-2
+
| 2019-M02
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 876.0
+
| style="text-align: right;" | 24.00 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
|
 
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
 
 
|  
 
|  
 +
|-
 +
| 2019-M03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 46.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 2090042
 
| 2090042
| 2012-07-16
+
| Primary Facility
 +
| 07/16/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| HORIZONTAL MMARCELLUS,KEANE # 2144 DRILLING ON AIR @ 231' (TD). RUNNING COAL PROTECTION CASING AND CEMENTING TONIGHT.
 
| HORIZONTAL MMARCELLUS,KEANE # 2144 DRILLING ON AIR @ 231' (TD). RUNNING COAL PROTECTION CASING AND CEMENTING TONIGHT.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2090043
 
| 2090043
| 2012-07-18
+
| Primary Facility
 +
| 07/18/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| HORIZONTAL MARCELLUS,KEANE# 2144 DRILLING ON AIR @ 705' (TD). RUNNING WATER PROTECTION CASING AND CEMENTING TONIGHT.
 
| HORIZONTAL MARCELLUS,KEANE# 2144 DRILLING ON AIR @ 705' (TD). RUNNING WATER PROTECTION CASING AND CEMENTING TONIGHT.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2090044
 
| 2090044
| 2012-07-22
+
| Primary Facility
 +
| 07/22/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| HORIZONTAL MARCELLUS, KEANE # 2144 DRILLING ON AIR @ 2302' (TD).RUNNING INTERMEDIATE CASING AND CEMENTING TODAY.
 
| HORIZONTAL MARCELLUS, KEANE # 2144 DRILLING ON AIR @ 2302' (TD).RUNNING INTERMEDIATE CASING AND CEMENTING TODAY.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2090045
 
| 2090045
| 2012-07-31
+
| Primary Facility
 +
| 07/31/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| HORIZONTAL MARCELLUS ,KEANE # 2144 DRILLING ON AIR @ 7100' (TD). RUNNING BRIDGE PLUG AND LOADING HOLE WITH OIL BASE MUD. CAPPING AND MOVING TO NEXT WELL (7/29/2012).
 
| HORIZONTAL MARCELLUS ,KEANE # 2144 DRILLING ON AIR @ 7100' (TD). RUNNING BRIDGE PLUG AND LOADING HOLE WITH OIL BASE MUD. CAPPING AND MOVING TO NEXT WELL (7/29/2012).
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2090046
 
| 2090046
| 2012-07-25
+
| Primary Facility
 +
| 07/25/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| HORIZONTAL MARCELLUS,KEANE # 2144 DRILLING ON AIR @ 3725' TODAY. ALL LOOKS GOOD.
 
| HORIZONTAL MARCELLUS,KEANE # 2144 DRILLING ON AIR @ 3725' TODAY. ALL LOOKS GOOD.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2092032
 
| 2092032
| 2012-08-15
+
| Primary Facility
 +
| 08/15/2012
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| 5 vertical and no horizontals drilled. Crew cleanimng frac tanks.
 
| 5 vertical and no horizontals drilled. Crew cleanimng frac tanks.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2094172
 
| 2094172
| 2012-07-30
+
| Primary Facility
 +
| 07/30/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| HORIZONTAL MARCELLUS, KEANE # 2144 DRILLING ON AIR @ 7100' (TD). RUNNING BRIDGE PLUG AND LOADING HOLE WITH OIL BASE MUD. CAPPING AND MOVING OVER TO NEXT WELL (7/28/2012).
 
| HORIZONTAL MARCELLUS, KEANE # 2144 DRILLING ON AIR @ 7100' (TD). RUNNING BRIDGE PLUG AND LOADING HOLE WITH OIL BASE MUD. CAPPING AND MOVING OVER TO NEXT WELL (7/28/2012).
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2103246
 
| 2103246
| 2012-09-05
+
| Primary Facility
 +
| 09/05/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| HORIZONTAL MARCELLUS, PATTERSON # 339  MOVING TO LESTER 7 - H (9/5/2012). RIGGING -UP AND TESTING (BOP).
 
| HORIZONTAL MARCELLUS, PATTERSON # 339  MOVING TO LESTER 7 - H (9/5/2012). RIGGING -UP AND TESTING (BOP).
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2103247
 
| 2103247
| 2012-09-10
+
| Primary Facility
 +
| 09/10/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| HORIZONTAL MARCELLUS, PATTERSON DRILLING ON FLUID @ 8310' TODAY.
 
| HORIZONTAL MARCELLUS, PATTERSON DRILLING ON FLUID @ 8310' TODAY.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2103255
 
| 2103255
| 2012-09-18
+
| Primary Facility
 +
| 09/18/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| HORIZONTAL MARCELLUS, PATTERSON # 339 DRILLING ON FLUID @ 12,563' ( TD). RUNNING 51/2" PROD. CASING AND CEMENTING ON (9/16/2012).
 
| HORIZONTAL MARCELLUS, PATTERSON # 339 DRILLING ON FLUID @ 12,563' ( TD). RUNNING 51/2" PROD. CASING AND CEMENTING ON (9/16/2012).
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2121528
 
| 2121528
| 2012-12-06
+
| Primary Facility
 +
| 12/06/2012
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| E&S, PPC, Permits in box, site ID sign up.  Some erosion issues at back of water impoundment being addressed by operator.  Will monitor further.
 
| E&S, PPC, Permits in box, site ID sign up.  Some erosion issues at back of water impoundment being addressed by operator.  Will monitor further.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2137237
 
| 2137237
| 2013-02-06
+
| Primary Facility
 +
| 02/06/2013
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Site ID sign up, Plans and permits in box, Site stable.  Impoundment reaching 2 foot freeboard, operator told and will pump level down.
 
| Site ID sign up, Plans and permits in box, Site stable.  Impoundment reaching 2 foot freeboard, operator told and will pump level down.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2139618
 
| 2139618
| 2013-02-15
+
| Primary Facility
 +
| 02/15/2013
 +
| Administrative/File Review
 
| In Compliance with Policy
 
| In Compliance with Policy
 
| Operator self reported a spill of 35 gallons of brine water to the pad.  Operator cleaned up material but some found its way under secondary containment.  The remainder of the spill will be addressed once equipment moves off location.  Operator cleaned up and reported spill in compliance with current Departments spill policy.
 
| Operator self reported a spill of 35 gallons of brine water to the pad.  Operator cleaned up material but some found its way under secondary containment.  The remainder of the spill will be addressed once equipment moves off location.  Operator cleaned up and reported spill in compliance with current Departments spill policy.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2184517
 
| 2184517
| 2013-07-18
+
| Primary Facility
 +
| 07/18/2013
 +
| Site Restoration
 
| No Violations Noted
 
| No Violations Noted
 
| Restoration extension request until 1/28/15.  Site stable and wells being hooked up.  Extension approved.
 
| Restoration extension request until 1/28/15.  Site stable and wells being hooked up.  Extension approved.
|
 
|
 
|
 
 
|-
 
|-
 +
| 2264219
 +
| Primary Facility
 +
| 04/21/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| 5 wells drilled and equipped. 4 tanks onsite. no open pits. Site graded and mulched.
 
|-
 
|-
 
| 2330208
 
| 2330208
| 2014-12-19
+
| Primary Facility
 +
| 12/19/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| At the time of inspection the well appeared to drilled and equipped for production.  The well apparatus, brine tanks and heater units appear to be in sound condition.  Site appeared to be in sound stable condition. The Departments suggests the Operator continue to monitor the site weekly and after significant precipitation events.
 +
|-
 +
| 2356019
 +
| Primary Facility
 +
| 03/26/2015
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| 5 wells onsite and equipped for production. 4 tanks onsite. Id sign ok. Site reclaimed.
 +
|-
 +
| 2374003
 +
| Primary Facility
 +
| 05/28/2015
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
| At the time of inspection the well appeared to drilled and equipped for production. The well apparatus
 
|
 
|
 
 
|  
 
|  
 
|-
 
|-
 +
| 2492875
 +
| Primary Facility
 +
| 2016-05-17
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On 05/17/16 at approximately 1400 hours I conducted a site restoration inspection in response to an NOT submittal by Chevron Appalachia LLC. The Act 9 sign was in place and all required documents were present in the mailbox. The site meets the standards required for permit termination. The NOT is approved.
 +
|-
 +
| 2523511
 +
| Primary Facility
 +
| 2016-09-20
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|  HORIZONTAL MARCELLUS, Well appears to  be producing natural gas.
 +
|-
 +
| 2585015
 +
| Primary Facility
 +
| 2017-04-20
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated but an erosion channel was observed along the access road. It is recommended that this be repaired to prevent further erosion. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection
 +
|-
 +
| 2735007
 +
| Primary Facility
 +
| 2018-05-29
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
 
|-
 
|-
| 2356019
+
| 2792983
| 2015-03-26
+
| Primary Facility
 +
| 2018-10-11
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
| 5 wells onsite and equipped for production. 4 tanks onsite. Id sign ok. Site reclaimed.
+
| The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
 +
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 03/20/2013
 +
| 03/20/2013
 +
| style="text-align: right;" | 7865.0
 +
| style="text-align: right;" | 3058979.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="12"| 1
 +
| rowspan="1"| Scale Inhibitor A
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Scale Inhibitor
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00696
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| ASP 900
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Friction Reducer
 +
| Ammonium Sulfate
 +
| 7783-20-2
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | None
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Iron Control A
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Iron Control
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00695
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Unislik ST 50
 +
| rowspan="1"| CESI
 +
| rowspan="1"| Friction Reducer
 +
| Hydrotreated Light Distillite
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.03302
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| 7.5 Hcl Acid
 +
| rowspan="1"| Reagent/PP G
 +
| rowspan="1"| Used to open perfs
 +
| Hydrochloric Acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 7.5
 +
| style="text-align: right;" | 0.25363
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Proppant (lbs)
 +
| rowspan="1"|
 +
| rowspan="1"| Proppant
 +
|
 
|  
 
|  
 +
| style="text-align: right;" | 10.36
 +
| style="text-align: right;" | 11.65404
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Clean Volume (gals)
 +
| rowspan="1"|
 +
| rowspan="1"| Carrier/Base Fluid
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" | 89.64
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| GBL
 +
| rowspan="1"| Clearwater
 +
| rowspan="1"| Gel Breaker
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 60.0
 +
| style="text-align: right;" | 0.00004000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| EC 6116a
 +
| rowspan="3"| Nalco
 +
| rowspan="3"| Biocide
 +
| 1,1-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00704
 +
| style="text-align: right;" |
 +
|-
 +
| Polyethylene Glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 60.0
 +
| style="text-align: right;" | 0.01408
 +
| style="text-align: right;" |
 +
|-
 +
| Dibromoacetonitrile
 +
| 3252-43-5
 +
| style="text-align: right;" | 5.0
 +
| style="text-align: right;" | 0.00117
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| CMHPG (lbs)
 +
| rowspan="1"| Ashland
 +
| rowspan="1"| Water Viscosifier
 +
| Carboxymethylhydroxyporoyl guar blend
 +
| Mixture
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 0.00287
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
==References==
== References ==
+
<references/>
{{reflist}}
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 15:00, 17 July 2019

Well Details

Well ID: 37-051-24507
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Jefferson Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148756
Farm/Lease Name: LESTER UNIT 7H
License Status: Active
Spud Date: 04/29/2012
Permit Date: 4/11/2012
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.065575
Longitude: -79.824881

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 550,055.00 275 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 839,846.00 365 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 564,893.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 398,442.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 321,411.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 273,355.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 62,436.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-S01 Drilling Fluid Waste (in Barrels) 367.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012-S02 Drill Cuttings (in Tons) 930.56 Tons LANDFILL 100419
2012-S02 Drilling Fluid Waste (in Barrels) 350.40 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012-S02 Drilling Fluid Waste (in Barrels) 580.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S02 Fracing Fluid Waste (in Barrels) 1,418.20 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Drilling Fluid Waste (in Barrels) 18.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013-S01 Fracing Fluid Waste (in Barrels) 1,490.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013-S01 Fracing Fluid Waste (in Barrels) 6,792.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Fracing Fluid Waste (in Barrels) 2,575.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013-S02 Fracing Fluid Waste (in Barrels) 9,555.80 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Fracturing Fluid Waste (in Tons) 87.59 Tons LANDFILL 100592
2013-S02 Produced Fluid (in Barrels) 1,217.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Fracturing Fluid Waste (in Tons) 7.08 Tons STORAGE PENDING DISPOSAL OR REUSE MID074259565
2014-S01 Produced Fluid (in Barrels) 1,677.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Fracing Fluid Waste (in Barrels) 3.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014-S02 Fracing Fluid Waste (in Barrels) 9.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 876.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 533.60 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 473.40 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 543.40 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 362.02 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-S02 Produced Fluid (in Barrels) RWC 802 66.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 46.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M02 Produced Fluid (in Barrels) RWC 802 69.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M03 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M03 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 22.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M04 Produced Fluid (in Barrels) RWC 802 26.00 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 966.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M06 Drilling Fluid Waste (in Barrels) RWC 803 24.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M07 Produced Fluid (in Barrels) RWC 802 22.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M07 Produced Fluid (in Barrels) RWC 802 22.40 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 23.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M08 Produced Fluid (in Barrels) RWC 802 22.40 Bbl REUSE (AT WELL PAD)
2017-M09 Produced Fluid (in Barrels) RWC 802 22.40 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 22.40 Bbl REUSE (AT WELL PAD)
2017-M11 Produced Fluid (in Barrels) RWC 802 26.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M12 Produced Fluid (in Barrels) RWC 802 42.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M01 Produced Fluid (in Barrels) RWC 802 22.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018-M01 Produced Fluid (in Barrels) RWC 802 23.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M02 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 43.80 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 45.00 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 22.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M05 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 44.00 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M08 Produced Fluid (in Barrels) RWC 802 45.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M09 Produced Fluid (in Barrels) RWC 802 42.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M11 Produced Fluid (in Barrels) RWC 802 23.00 Bbl REUSE (AT WELL PAD)
2018-M11 Produced Fluid (in Barrels) RWC 802 42.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M12 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M01 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 24.00 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 46.00 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2090042 Primary Facility 07/16/2012 Drilling/Alteration No Violations Noted HORIZONTAL MMARCELLUS,KEANE # 2144 DRILLING ON AIR @ 231' (TD). RUNNING COAL PROTECTION CASING AND CEMENTING TONIGHT.
2090043 Primary Facility 07/18/2012 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,KEANE# 2144 DRILLING ON AIR @ 705' (TD). RUNNING WATER PROTECTION CASING AND CEMENTING TONIGHT.
2090044 Primary Facility 07/22/2012 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, KEANE # 2144 DRILLING ON AIR @ 2302' (TD).RUNNING INTERMEDIATE CASING AND CEMENTING TODAY.
2090045 Primary Facility 07/31/2012 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS ,KEANE # 2144 DRILLING ON AIR @ 7100' (TD). RUNNING BRIDGE PLUG AND LOADING HOLE WITH OIL BASE MUD. CAPPING AND MOVING TO NEXT WELL (7/29/2012).
2090046 Primary Facility 07/25/2012 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,KEANE # 2144 DRILLING ON AIR @ 3725' TODAY. ALL LOOKS GOOD.
2092032 Primary Facility 08/15/2012 Complaint Inspection No Violations Noted 5 vertical and no horizontals drilled. Crew cleanimng frac tanks.
2094172 Primary Facility 07/30/2012 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, KEANE # 2144 DRILLING ON AIR @ 7100' (TD). RUNNING BRIDGE PLUG AND LOADING HOLE WITH OIL BASE MUD. CAPPING AND MOVING OVER TO NEXT WELL (7/28/2012).
2103246 Primary Facility 09/05/2012 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 339 MOVING TO LESTER 7 - H (9/5/2012). RIGGING -UP AND TESTING (BOP).
2103247 Primary Facility 09/10/2012 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON DRILLING ON FLUID @ 8310' TODAY.
2103255 Primary Facility 09/18/2012 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 339 DRILLING ON FLUID @ 12,563' ( TD). RUNNING 51/2" PROD. CASING AND CEMENTING ON (9/16/2012).
2121528 Primary Facility 12/06/2012 Routine/Complete Inspection No Violations Noted E&S, PPC, Permits in box, site ID sign up. Some erosion issues at back of water impoundment being addressed by operator. Will monitor further.
2137237 Primary Facility 02/06/2013 Routine/Complete Inspection No Violations Noted Site ID sign up, Plans and permits in box, Site stable. Impoundment reaching 2 foot freeboard, operator told and will pump level down.
2139618 Primary Facility 02/15/2013 Administrative/File Review In Compliance with Policy Operator self reported a spill of 35 gallons of brine water to the pad. Operator cleaned up material but some found its way under secondary containment. The remainder of the spill will be addressed once equipment moves off location. Operator cleaned up and reported spill in compliance with current Departments spill policy.
2184517 Primary Facility 07/18/2013 Site Restoration No Violations Noted Restoration extension request until 1/28/15. Site stable and wells being hooked up. Extension approved.
2264219 Primary Facility 04/21/2014 Routine/Complete Inspection No Violations Noted 5 wells drilled and equipped. 4 tanks onsite. no open pits. Site graded and mulched.
2330208 Primary Facility 12/19/2014 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to drilled and equipped for production. The well apparatus, brine tanks and heater units appear to be in sound condition. Site appeared to be in sound stable condition. The Departments suggests the Operator continue to monitor the site weekly and after significant precipitation events.
2356019 Primary Facility 03/26/2015 Routine/Complete Inspection No Violations Noted 5 wells onsite and equipped for production. 4 tanks onsite. Id sign ok. Site reclaimed.
2374003 Primary Facility 05/28/2015 Routine/Complete Inspection No Violations Noted
2492875 Primary Facility 2016-05-17 Routine/Complete Inspection No Violations Noted On 05/17/16 at approximately 1400 hours I conducted a site restoration inspection in response to an NOT submittal by Chevron Appalachia LLC. The Act 9 sign was in place and all required documents were present in the mailbox. The site meets the standards required for permit termination. The NOT is approved.
2523511 Primary Facility 2016-09-20 Routine/Complete Inspection No Violations Noted HORIZONTAL MARCELLUS, Well appears to be producing natural gas.
2585015 Primary Facility 2017-04-20 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated but an erosion channel was observed along the access road. It is recommended that this be repaired to prevent further erosion. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection
2735007 Primary Facility 2018-05-29 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2792983 Primary Facility 2018-10-11 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 03/20/2013 03/20/2013 7865.0 3058979.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Scale Inhibitor A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30.0 0.00696
ASP 900 Nalco Friction Reducer Ammonium Sulfate 7783-20-2 30.0 None
Iron Control A Nalco Iron Control Ethylene Glycol 107-21-1 30.0 0.00695
Unislik ST 50 CESI Friction Reducer Hydrotreated Light Distillite 64742-47-8 30.0 0.03302
7.5 Hcl Acid Reagent/PP G Used to open perfs Hydrochloric Acid 7647-01-0 7.5 0.25363
Proppant (lbs) Proppant 10.36 11.65404
Clean Volume (gals) Carrier/Base Fluid 89.64 100.0
GBL Clearwater Gel Breaker Ethylene Glycol 107-21-1 60.0 0.00004000
EC 6116a Nalco Biocide 1,1-Dibromo-3-nitrilopropionamide 10222-01-2 30.0 0.00704
Polyethylene Glycol 25322-68-3 60.0 0.01408
Dibromoacetonitrile 3252-43-5 5.0 0.00117
CMHPG (lbs) Ashland Water Viscosifier Carboxymethylhydroxyporoyl guar blend Mixture 100.0 0.00287

For data sources see[7]