X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-051-24607

Well Details

Well ID: 37-051-24607
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Washington Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 150856
Farm/Lease Name: SICKLE UNIT 1H
License Status: Active
Spud Date: 2014-07-29
Permit Date: 2014-02-14
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.118739
Longitude: -79.786542

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-03-22 2015-04-06 8077 10,551,300.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 A264 Schlumberger Corrosion Inhibitor Aliphatic alcohols, ethoxylayed #1 Proprietary 30 0.00004267 0
Prop-2-yn-1-ol 107-19-7 10 0.00001422 0
Aliphatic acids Proprietary 30 0.00004267 0
Methanol 67-56-1 40 0.00005689 0
M300 BASF Corporation Biocide Water 7732-18-5 75 0.00167711 0
Glutaral 111-30-8 25 0.00055904 0
U042 Schlumberger Iron Chelating Agent Tetrasodium ethylenediam inetetraacetate 64-02-8 60 0.00163751 0
Sodium hydroxide 1310-73-2 5 0.00013646 0
Trisodium nitrilotriacetate (im purity) 5064-31-3 10 0.00027292 0
Proppant Schlumberger Proppant Crystalline Silica 14808-60-7 100 10.2094 0
J609W Schlumberger Friction Reducer Urea 57-13-6 5 0.00059937 0
Ammonium Sulfate 7783-20-2 30 0.00359619 0
J134 Schlumberger Gel Breaker Hemicellulase enzyme 9012-54-8 100 0.00128674 0
J580 Schlumberger Gelling Agent, Water Carbohydrate Polymer Proprietary 100 0.0287172 0
Base Fluid Chevron Carrier/Base Fluid Water (Including Mix Water Supplied by Client) 7732-18-5 100 89.5912 0
15% Acid Schlumberger Perf Cleanup Hydrocloric Acid 7647-01-0 15 0.00065798 0
B317 Schlumberger Scale Inhibitor Ethane-1,2-diol 107-21-1 5 0.00010543 0
Trisodium ortho phosphate 7601-54-9 5 0.00010543 0
L058 Schlumberger Iron Stabilizer Sodium erythorbate 6381-77-7 100 0.00051388 0
7.5% Acid Schlumberger Perf Cleanup Hydrocloric Acid 7647-01-0 8 0.0115401 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 1,023,149.00 146 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 1,582,803.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 1,125,179.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 735,323.00 303 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 133,125.00 62 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2014-S02 Drill Cuttings (in Tons) 195.93 Tons LANDFILL 100172
2014-S02 Drill Cuttings (in Tons) 669.89 Tons LANDFILL 100592
2014-S02 Drill Cuttings (in Tons) 221.80 Tons LANDFILL 100663
2014-S02 Drilling Fluid Waste (in Barrels) 619.57 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014-S02 Fracing Fluid Waste (in Barrels) 14.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014-S02 Fracing Fluid Waste (in Barrels) 36.43 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Drill Cuttings (in Tons) 41.97 Tons LANDFILL 100172
2015-S01 Drill Cuttings (in Tons) 215.04 Tons LANDFILL 100592
2015-S01 Drilling Fluid Waste (in Barrels) 105.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015-S01 Fracing Fluid Waste (in Barrels) 4,378.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015-S01 Fracturing Fluid Waste (in Tons) 70.55 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2015-S01 Fracturing Fluid Waste (in Tons) 2.51 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2015-S01 Produced Fluid (in Barrels) 64.29 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Fracing Fluid Waste (in Barrels) 267.86 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015-S02 Fracing Fluid Waste (in Barrels) 0.04 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2015-S02 Fracing Fluid Waste (in Barrels) 5,032.86 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Fracturing Fluid Waste (in Tons) 1.77 Tons LANDFILL 100172
2015-S02 Produced Fluid (in Barrels) 6,327.43 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Filter Socks (in Tons) RWC 812 0.08 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2016-S01 Produced Fluid (in Barrels) RWC 802 15.71 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-S01 Produced Fluid (in Barrels) RWC 802 3,595.43 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 28.57 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2016-S02 Produced Fluid (in Barrels) RWC 802 2,059.24 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-S02 Produced Fluid (in Barrels) RWC 802 368.88 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 271.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M02 Produced Fluid (in Barrels) RWC 802 270.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M03 Produced Fluid (in Barrels) RWC 802 131.13 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M03 Produced Fluid (in Barrels) RWC 802 113.00 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 62.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M04 Produced Fluid (in Barrels) RWC 802 31.43 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 7,506.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M06 Drilling Fluid Waste (in Barrels) RWC 803 49.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M06 Produced Fluid (in Barrels) RWC 802 84.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M06 Produced Fluid (in Barrels) RWC 802 17.14 Bbl REUSE (AT WELL PAD)
2017-M07 Produced Fluid (in Barrels) RWC 802 48.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M07 Produced Fluid (in Barrels) RWC 802 65.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-M07 Produced Fluid (in Barrels) RWC 802 16.43 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 32.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M08 Produced Fluid (in Barrels) RWC 802 51.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-M08 Produced Fluid (in Barrels) RWC 802 15.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M08 Produced Fluid (in Barrels) RWC 802 32.14 Bbl REUSE (AT WELL PAD)
2017-M09 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2017-M09 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M10 Produced Fluid (in Barrels) RWC 802 16.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M10 Produced Fluid (in Barrels) RWC 802 16.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-M10 Produced Fluid (in Barrels) RWC 802 16.43 Bbl REUSE (AT WELL PAD)
2017-M11 Produced Fluid (in Barrels) RWC 802 32.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-M11 Produced Fluid (in Barrels) RWC 802 126.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M12 Produced Fluid (in Barrels) RWC 802 15.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M12 Produced Fluid (in Barrels) RWC 802 131.68 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M01 Produced Fluid (in Barrels) RWC 802 31.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M01 Produced Fluid (in Barrels) RWC 802 48.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018-M01 Produced Fluid (in Barrels) RWC 802 125.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M02 Produced Fluid (in Barrels) RWC 802 31.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018-M02 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 17.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M03 Produced Fluid (in Barrels) RWC 802 31.86 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 29.29 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M04 Produced Fluid (in Barrels) RWC 802 17.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M04 Produced Fluid (in Barrels) RWC 802 31.43 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 16.43 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M05 Produced Fluid (in Barrels) RWC 802 15.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M05 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 32.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M06 Produced Fluid (in Barrels) RWC 802 31.86 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 47.86 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M07 Produced Fluid (in Barrels) RWC 802 31.43 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 79.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M08 Produced Fluid (in Barrels) RWC 802 109.29 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M09 Produced Fluid (in Barrels) RWC 802 29.86 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 120.57 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M10 Produced Fluid (in Barrels) RWC 802 782.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M11 Produced Fluid (in Barrels) RWC 802 156.57 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M12 Produced Fluid (in Barrels) RWC 802 16.00 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 62.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M01 Produced Fluid (in Barrels) RWC 802 34.29 Bbl REUSE (AT WELL PAD)
2019-M01 Produced Fluid (in Barrels) RWC 802 17.14 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M02 Produced Fluid (in Barrels) RWC 802 48.57 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M03 Drilling Fluid Waste (in Barrels) RWC 803 15.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019-M03 Produced Fluid (in Barrels) RWC 802 148.57 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2298788 Primary Facility 2014-08-01 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, CONDUCTOR SET @ 55' AND CEMENTED IN (7/30/2014).
2299750 Primary Facility 2014-08-12 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 14 MOVING ON TO LOCATION SICKLE # 1 - H TODAY (SETTING -UP).
2299767 Primary Facility 2014-08-14 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 14 RAN WATER PROTECTION CASING AND CEMENTED LAST NIGHT.NO CEMENT RETURNS TO SURFACE. LOST CIRCULATION AND BACK GROUTED WITH NO NOTIFICATION TO THE DEPARTMENT.A (CBL) WAS RECOMMENDED AT THIS TIME.
2299781 Primary Facility 2014-08-15 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 14 (TD) COAL PROTECTION @ 504' (8/13/2014) . CEMENTING TONIGHT
2313118 Primary Facility 2014-10-10 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON 10.4 WATER BASE MUD @2423' (TD). RUNNING INTERMEDIATE CASING AND CEMENTING TONIGHT(10/10/2014). RIG IS IN PROCESS OF MOVING TO SICKLE # 2 WHILE CEMENTING # 1 INTERMEDIATE CASING.
2338804 Primary Facility 2015-01-21 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, Drilling oin oil base mud @7,695' today.E&S controls look in good condition.
2360459 Primary Facility 2015-04-02 Complaint Inspection No Violations Noted At time of inspection, pumps utilized for frac’g operations in process of being replaced and set-up of waterlines to 1H also occurring. 1H, 2H frac’d. Frac’g of 3H completed this morning. 4H, 5H, 6H, 7H perforated, not yet frac’d.
2373945 Primary Facility 2015-05-28 Site Restoration No Violations Noted
2504356 Primary Facility 2016-06-01 Routine/Complete Inspection No Violations Noted

On 06/01/16 at approximately 1400 hours I conducted a routine complete inspection of the Sickle Unit. The Act 9 sign was in place and all required documents were present at the mail box. The site was well vegetated and the site had been partially reclaimed. An area along the access road appeared to have been recently restored and graded. There were no violations observed at the time of inspection.

2523476 Primary Facility 2016-09-08 Routine/Complete Inspection No Violations Noted HORIZONTAL MARCELLUS, Well appears to be producing natural gas.
2682075 Primary Facility 2018-01-10 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2734811 Primary Facility 2018-05-29 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2768832 Primary Facility 2018-08-23 Routine/Partial Inspection No Violations Noted On 08/23/18 at approximately 1200 hours I met Curtis Small of Chevron to discuss transferring previously approved redlines to the PCSM page prior to Chevron submitting for an NOT. The Act 9 sign was in place and all required documents were present at the site. Redlines approved in 2014 were transferred to the PCSM sheet.

A small fluid release was observed on the site entrance outside the gated area. The fluid appeared to be similar in type to hydraulic fluid. A line of spilled fluid was observed leaving the site and continuing down the road. During the inspection agricultural equipment was observed traveling back and forth on the roadway adjacent to the site.

2809336 Primary Facility 2018-11-21 Site Restoration No Violations Noted A site restoration inspection was conducted in response to an NOT submittal from Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The site met and exceeded uniform 70% vegetative cover. PCSM features were installed and appeared to be functioning. The NOT is approved.

For data sources see[7]

References