m
 
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-059-25688
 
| Well ID: 37-059-25688
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.921950, -80.218186 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 39.921950, -80.218186 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 19: Line 19:
 
| Farm/Lease Name: GROOMS UNIT 10H
 
| Farm/Lease Name: GROOMS UNIT 10H
 
|-
 
|-
| License Status: Active
+
| License Status:  
 
|-
 
|-
| Spud Date: 2011-08-28
+
| Spud Date:  
 
|-
 
|-
 
| Permit Date: 2011-03-14
 
| Permit Date: 2011-03-14
 +
|-
 +
| Well Type: GAS
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
 
|-
 
|-
 
| Configuration: Horizontal Well
 
| Configuration: Horizontal Well
 +
|-
 +
| Conservation: Yes
 
|-
 
|-
 
| Latitude: 39.921950
 
| Latitude: 39.921950
Line 49: Line 53:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2011-03-14
 +
| New Permit Application
 +
|-
 +
| 2011-08-28
 +
| Performed Spud Operation
 +
|-
 +
| 2012-04-15
 +
| Drilling Completion
 +
|-
 +
| 2012-09-18
 +
| Perforation
 +
|-
 +
| 2012-09-20
 +
| Performed Stimulation 
 +
|-
 +
| 2013-07-18
 +
| DEVIATED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 
== Fracking Activities ==
 
== Fracking Activities ==
 
==== Fracking Jobs ====
 
==== Fracking Jobs ====
Line 62: Line 95:
 
| 2012-09-18
 
| 2012-09-18
 
| 2012-09-18
 
| 2012-09-18
| style="text-align: right;" | 6191.00
+
| style="text-align: right;" | 6,191
| style="text-align: right;" | 2,899,035.0
+
| style="text-align: right;" | 2,899,035
 
| style="text-align: right;" |  
 
| style="text-align: right;" |  
 
|-
 
|-
Line 198: Line 231:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-06-19 }}</ref>
 
  | accessdate = 2019-06-19 }}</ref>
 +
== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
| 2012-09-20
 +
| style="text-align: right;" |
 +
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Completion Reports - Stimulations
 +
| publisher = Pennsylvania Department of Conservation and Natural Resources
 +
| date = 2020-03-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-03-02 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 283: Line 339:
 
| 2019
 
| 2019
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 42,305.00
+
| style="text-align: right;" | 152,304.00
| style="text-align: right;" | 90
+
| style="text-align: right;" | 365
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
Line 308: Line 364:
 
| 2012
 
| 2012
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Drilling Fluid Waste (in Barrels)
+
| Fracing Fluid Waste
| style="text-align: right;" | 3,265.00 Bbl
+
| style="text-align: right;" | 4,770.15 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 1,170.02 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW001
 
| WMGR123SW001
Line 315: Line 378:
 
| 2012
 
| 2012
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracing Fluid Waste (in Barrels)
+
| Drilling Fluid Waste
| style="text-align: right;" | 4,770.15 Bbl
+
| style="text-align: right;" | 3,265.00 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
|  
+
| WMGR123SW001
 
|-
 
|-
| 2012
+
| 2013
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracing Fluid Waste (in Barrels)
+
| Fracing Fluid Waste
| style="text-align: right;" | 1,170.02 Bbl
+
| style="text-align: right;" | 17.50 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW001
 
| WMGR123SW001
Line 329: Line 392:
 
| 2013
 
| 2013
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracturing Fluid Waste (in Tons)
+
| Fracturing Fluid Waste
 
| style="text-align: right;" | 27.71 Tons
 
| style="text-align: right;" | 27.71 Tons
 
| LANDFILL
 
| LANDFILL
Line 336: Line 399:
 
| 2013
 
| 2013
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracing Fluid Waste (in Barrels)
+
| Produced Fluid
| style="text-align: right;" | 17.50 Bbl
+
| style="text-align: right;" | 660.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| REUSE OTHER THAN ROAD SPREADING
| WMGR123SW001
+
|  
 
|-
 
|-
 
| 2013
 
| 2013
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracing Fluid Waste (in Barrels)
+
| Fracing Fluid Waste
 
| style="text-align: right;" | 536.25 Bbl
 
| style="text-align: right;" | 536.25 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
Line 350: Line 413:
 
| 2013
 
| 2013
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracing Fluid Waste (in Barrels)
+
| Fracing Fluid Waste
 
| style="text-align: right;" | 3,853.38 Bbl
 
| style="text-align: right;" | 3,853.38 Bbl
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2013
 
| [[CHEVRON APPALACHIA LLC]]
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 660.00 Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
Line 364: Line 420:
 
| 2014
 
| 2014
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels)
+
| Produced Fluid
| style="text-align: right;" | 1,589.75 Bbl
+
| style="text-align: right;" | 23.75 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| INJECTION DISPOSAL WELL
|  
+
| 34-121-23995
 
|-
 
|-
 
| 2014
 
| 2014
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracturing Fluid Waste (in Tons)
+
| Fracturing Fluid Waste
 
| style="text-align: right;" | 2.22 Tons
 
| style="text-align: right;" | 2.22 Tons
 
| LANDFILL
 
| LANDFILL
Line 378: Line 434:
 
| 2014
 
| 2014
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels)
+
| Produced Fluid
 
| style="text-align: right;" | 390.75 Bbl
 
| style="text-align: right;" | 390.75 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
Line 385: Line 441:
 
| 2014
 
| 2014
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels)
+
| Produced Fluid
| style="text-align: right;" | 23.75 Bbl
+
| style="text-align: right;" | 1,589.75 Bbl
| INJECTION DISPOSAL WELL
+
| REUSE OTHER THAN ROAD SPREADING
| 34-121-23995
+
|  
 
|-
 
|-
 
| 2015
 
| 2015
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels)
+
| Produced Fluid
 
| style="text-align: right;" | 1,298.75 Bbl
 
| style="text-align: right;" | 1,298.75 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
Line 399: Line 455:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
 
| style="text-align: right;" | 444.13 Bbl
 
| style="text-align: right;" | 444.13 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
Line 406: Line 462:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
 
| style="text-align: right;" | 756.57 Bbl
 
| style="text-align: right;" | 756.57 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
Line 413: Line 469:
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Soil Contaminated by Oil
| style="text-align: right;" | 692.51 Bbl
+
| style="text-align: right;" | 0.03 Tons
| REUSE (AT WELL PAD)
+
| RESIDUAL WASTE TRANSFER FACILITY
|  
+
| 101532
 +
|-
 +
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 15.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28776
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 210.10 Bbl
+
| style="text-align: right;" | 136.13 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| WMGR123SW019
+
|  
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
+
| Soil Contaminated by Oil & Gas Related Spills
 
| style="text-align: right;" | 0.03 Tons
 
| style="text-align: right;" | 0.03 Tons
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
Line 434: Line 497:
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 136.13 Bbl
+
| style="text-align: right;" | 210.10 Bbl
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
+
| RESIDUAL WASTE PROCESSING FACILITY
|  
+
| WMGR123SW019
 +
|-
 +
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 13.75 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
Line 448: Line 518:
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 15.00 Bbl
+
| style="text-align: right;" | 773.76 Bbl
| INJECTION DISPOSAL WELL
+
| REUSE (AT WELL PAD)
| 34-119-28776
+
|  
 
|-
 
|-
| 2017
+
| 2018
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 13.75 Bbl
+
| style="text-align: right;" | 234.39 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| REUSE (AT WELL PAD)
| WMGR123SW005
+
|  
 
|-
 
|-
 
| 2018
 
| 2018
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
 
| style="text-align: right;" | 203.00 Bbl
 
| style="text-align: right;" | 203.00 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
Line 469: Line 539:
 
| 2018
 
| 2018
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
 
| style="text-align: right;" | 955.40 Bbl
 
| style="text-align: right;" | 955.40 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
Line 476: Line 546:
 
| 2018
 
| 2018
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 193.76 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018
 
| [[CHEVRON APPALACHIA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
 
| style="text-align: right;" | 40.63 Bbl
 
| style="text-align: right;" | 40.63 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
Line 490: Line 553:
 
| 2019
 
| 2019
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 86.25 Bbl
+
| style="text-align: right;" | 31.25 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 +
|-
 +
| 2019
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 290.00 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  

Latest revision as of 21:06, 14 May 2020

Well Details

Well ID: 37-059-25688
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Franklin Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148450
Farm/Lease Name: GROOMS UNIT 10H
License Status:
Spud Date:
Permit Date: 2011-03-14
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.921950
Longitude: -80.218186

For data sources see[1][2][3]

Well History

Date Event
2011-03-14 New Permit Application
2011-08-28 Performed Spud Operation
2012-04-15 Drilling Completion
2012-09-18 Perforation
2012-09-20 Performed Stimulation
2013-07-18 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-09-18 2012-09-18 6,191 2,899,035

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
Unislik ST 50 CESI Chemical Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
Scale Inhibitor A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00696000
Clean Volume (gals) Carrier/Base Fluid 91.40 100.00
Proppant (lbs) Proppant 8.60 9.49
CMHPG Ashland Water Viscosifier Carboxymethylhydroxyporoyl guar blend 100.00 0.00322000
Biocide EC 6116A Nalco Biocide Dibromoacetonitrile 3252-43-5 5.00 0.00117000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00704000
Polyethylene glycol 25322-68-3 60.00 0.01
GBL Clearwater International Gel Breaker Ethylene glycol 107-21-1 60.00 0.00005000
Iron Control A Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00704000
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.27

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-09-20 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 44,820.00 31 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 701,229.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 419,102.00 365 0.00 0 133.76 184
2015 CHEVRON APPALACHIA LLC 300,444.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 240,557.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 201,734.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 177,159.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 152,304.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 4,770.15 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,170.02 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 3,265.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 17.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 27.71 Tons LANDFILL 073 114 654
2013 CHEVRON APPALACHIA LLC Produced Fluid 660.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 536.25 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 3,853.38 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 23.75 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 2.22 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Produced Fluid 390.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid 1,589.75 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 1,298.75 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 444.13 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 756.57 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Soil Contaminated by Oil 0.03 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 CHEVRON APPALACHIA LLC Produced Fluid 15.00 Bbl INJECTION DISPOSAL WELL 34-119-28776
2017 CHEVRON APPALACHIA LLC Produced Fluid 136.13 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Soil Contaminated by Oil & Gas Related Spills 0.03 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 CHEVRON APPALACHIA LLC Produced Fluid 210.10 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 13.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Produced Fluid 55.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017 CHEVRON APPALACHIA LLC Produced Fluid 773.76 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 234.39 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 203.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 955.40 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 40.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 31.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 290.00 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2006243 Primary Facility 2011-09-21 Drilling/Alteration No Violations Noted CONDUCTOR IS SET AT 100'. NO OTHER DRILLING.
2027578 Primary Facility 2011-09-13 Routine/Complete Inspection No Violations Noted The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The operator is finishing up construction of the pad and lining the pits. The Department reviewed the E/S Plan on site. The E/S controls appear to be in good condition. The Operator is currently adding E/S controls to make sure all the sediment stays on site. Temporary stabilization has been obtained on this site. Grass is beginning to grow on the fill slopes.
2035021 Primary Facility 2012-01-09 Drilling/Alteration No Violations Noted WELL DRILLED TO KOP. SITE AND E&S OK.
2057339 Primary Facility 2012-04-04 Drilling/Alteration No Violations Noted PATTERSON 334 DRILLING FOR CHEVRON.DRILLING AT TIME OF INSPECTION AT 5031' KOP AT 6000'.
2449065 Primary Facility 2016-01-09 Routine/Partial Inspection No Violations Noted On 01/09/16 at approximately 0800 hours I conducted a routine partial inspection of the Grooms Unit. The Act 9 sign was in place and all required documents were present at the site. I met with Nick Staffieri of Chevron to discuss changes at the site.

One of the forebays on the site (#3) was moved within the same drainage area as proposed, but without Departmental approval. This is a violation of 102.5(m)(4). It is recommended that Chevron submit for a minor modification to reflect current conditions at the site.

2636965 Primary Facility 2017-09-15 Site Restoration No Violations Noted A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and meets and exceeds 70% uniform vegetative cover. There were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. The site meets the requirements for permit termination. The NOT is approved.

For data sources see[9]

References