If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-059-26092 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.818833,"lon":-80.036136,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Greene Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 144566 | |
Farm/Lease Name: JOHNSON UNIT 16H | |
License Status: Active | |
Spud Date: 04/01/2013 | |
Permit Date: 2/7/2013 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.818833 | |
Longitude: -80.036136 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 1,135,024.00 | 239 | 0.00 | 0 | 37.50 | 184 |
2015 | CHEVRON APPALACHIA LLC | 957,921.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 674,954.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 534,823.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 443,609.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 100,095.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2013-1 | Drill Cuttings (in Tons) | 7.56 Tons | LANDFILL | 100419 |
2013-2 | Drill Cuttings (in Tons) | 1,255.08 Tons | LANDFILL | 100172 |
2013-2 | Drilling Fluid Waste (in Barrels) | 12,402.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2013-2 | Fracing Fluid Waste (in Barrels) | 672.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2013-2 | Fracing Fluid Waste (in Barrels) | 200.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Fracing Fluid Waste (in Barrels) | 13,135.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-1 | Fracing Fluid Waste (in Barrels) | 36,076.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Fracturing Fluid Waste (in Tons) | 36.50 Tons | LANDFILL | 100172 |
2014-1 | Produced Fluid (in Barrels) | 2,657.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Fracing Fluid Waste (in Barrels) | 360.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-2 | Fracturing Fluid Waste (in Tons) | 56.82 Tons | LANDFILL | 100172 |
2014-2 | Fracturing Fluid Waste (in Tons) | 37.83 Tons | LANDFILL | 100592 |
2014-2 | Fracturing Fluid Waste (in Tons) | 108.61 Tons | LANDFILL | 100663 |
2014-2 | Produced Fluid (in Barrels) | 37.50 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014-2 | Produced Fluid (in Barrels) | 9,081.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Produced Fluid (in Barrels) | 3,905.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Produced Fluid (in Barrels) | 2,855.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 2,431.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 1,625.82 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 320.02 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 240.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 189.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 125.98 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 124.00 Bbl | REUSE (AT WELL PAD) | |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 114.50 Bbl | REUSE (AT WELL PAD) | |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 7,350.00 Bbl | REUSE (AT WELL PAD) | |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 172.50 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 115.00 Bbl | REUSE (AT WELL PAD) | |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 60.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 115.00 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 165.00 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 52.50 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 168.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 57.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 112.00 Bbl | REUSE (AT WELL PAD) | |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | REUSE (AT WELL PAD) | |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 57.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 57.50 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 57.00 Bbl | REUSE (AT WELL PAD) | |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 112.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | REUSE (AT WELL PAD) | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 57.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-10 | Produced Fluid (in Barrels) RWC 802 | 210.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | REUSE (AT WELL PAD) | |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 56.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 115.00 Bbl | REUSE (AT WELL PAD) | |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 60.00 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 175.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2160323 | Primary Facility | 02/11/2013 | Routine/Complete Inspection | No Violations Noted | The Department was at the above referenced Marcellus Well site to conduct a pre-operation inspection. The E/S plan is on site and has been reviewed. The E/S BMP's are in place and appear to be in good condition. |
2162437 | Primary Facility | 04/11/2013 | Drilling/Alteration | No Violations Noted | CONDUCTOR SET. WAITING FOR RIG TO MOVE IN AND COMMENCE DRILLING. |
2206208 | Primary Facility | 09/12/2013 | Drilling/Alteration | No Violations Noted | VERTICAL SECTION OF WELL DRILLED TO COMPLETION. HORIZONTAL RIG ON SITE. WILL SKID TO THIS HOLE AND COMMENCE DRILLING WHEN FINISHED WITH DRILLING OF JOHNSON 17-H. |
2211165 | Primary Facility | 09/26/2013 | Routine/Complete Inspection | No Violations Noted | On 9/26/2013, I performed an inspection of Chevron Johnson well pad site. The site is located in Greene Twp., Greene County. The inspection was a routine inspection during drilling. |
2285017 | Primary Facility | 07/08/2014 | Routine/Complete Inspection | No Violations Noted | Well in compliance. |
2598026 | Primary Facility | 2017-05-08 | Routine/Complete Inspection | No Violations Noted | An inspection was conducted in response to Chevron submitting a well site restoration report. The Act 9 sign was in place and all required documents were present at the site. The site was found to be restored. There were no violations observed at the time of inspection. |
2672653 | Primary Facility | 2017-12-14 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2689093 | Primary Facility | 2018-01-28 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The purpose of the inspection was to meet with Chevron to discuss redline changes for rip rap that was previously installed at the site. The red line changes were approved and a photograph documenting the altered E&S plans is attached. |
2693597 | Primary Facility | 2018-02-05 | Site Restoration | No Violations Noted | A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The production equipment appeared to be in good condition. The site was well vegetated and there were no signs of erosion observed. The site meets and exceeds uniform 70% vegetative cover. The NOT is approved. |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 11/30/2013 | 12/05/2013 | 8308 | 3,880,820.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | EC6673W | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30 | 0.00007005 | 0 |
FR-66 | Halliburton | Friction Reducer | Hydrotreated Light Distillite | 64742-47-8 | 30 | 0.00032735 | 0 | |
WG-36 | Halliburton | Water Viscosifier | Guar Gum | 9000-30-0 | 100 | 0.00001439 | 0 | |
GBW-30 | Halliburton | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 15 | 0.00000070 | 0 | |
Carbohydrates | 87246-72-8 | 95 | 0.00000446 | 0 | ||||
EC 6116a | Nalco | Biocide | Dibromoacetonitrile | 3252-43-5 | 5 | 0.00001264 | 0 | |
Polyethylene Glycol | 25322-68-3 | 60 | 0.00015164 | 0 | ||||
1, 1-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00007582 | 0 | ||||
EC6486A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00007265 | 0 | |
Proppant | Halliburton | Proppant | Crystalline Silica | 14808-60-7 | 100 | 9.15 | 0 | |
Clean Volume | Chevron Applachia, LLC | Carrier/Base Fluid | H20 | 7732-18-5 | 100 | 90.89 | 0 | |
15% Hcl Acid | Reagent/PPG | Used to open perfs | Hydrochloric Acid | 7647-01-0 | 15 | 0.00086858 | 0 |
For data sources see[7]