If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-059-26113 | | Well ID: 37-059-26113 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 39.785089, -80.028936 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | Municipality: [[Dunkard Township, | + | | State: Pennsylvania |
+ | |- | ||
+ | | County: [[Greene_County,_Pennsylvania|Greene]] | ||
+ | |- | ||
+ | | Municipality: [[Dunkard Township,_Greene_County,_Pennsylvania|Dunkard Township]] | ||
|- | |- | ||
| Operator Name: [[CHEVRON APPALACHIA LLC]] | | Operator Name: [[CHEVRON APPALACHIA LLC]] | ||
|- | |- | ||
− | | Well Pad ID: [[ | + | | Well Pad ID: [[144823]] |
|- | |- | ||
| Farm/Lease Name: MILLER UNIT 77H | | Farm/Lease Name: MILLER UNIT 77H | ||
|- | |- | ||
− | | | + | | License Status: Active |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | Spud Date: 03/19/2013 |
|- | |- | ||
− | | | + | | Permit Date: 2/27/2013 |
|- | |- | ||
− | | Well | + | | Unconventional Well: Y |
|- | |- | ||
− | | | + | | Configuration: Horizontal Well |
|- | |- | ||
− | | Latitude: 39. | + | | Latitude: 39.785089 |
|- | |- | ||
| Longitude: -80.028936 | | Longitude: -80.028936 | ||
− | |||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator Name |
− | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
− | !scope="col" | | + | !scope="col" | Gas Production Days |
− | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
− | !scope="col" | | + | !scope="col" | Oil Production Days |
− | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
− | + | !scope="col" | Water Production Days | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
− | | | + | | 2013 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2014 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 56,028.00 | ||
+ | | style="text-align: right;" | 36 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,338,576.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2016 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 873,247.00 | ||
+ | | style="text-align: right;" | 366 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 673,921.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2018 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 558,288.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2019 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 123,110.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 90 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2013-1 | | 2013-1 | ||
− | | | + | | Drill Cuttings (in Tons) |
− | | style="text-align:right;" | 354.61 | + | | style="text-align: right;" | 354.61 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100419 | | 100419 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2013-1 | ||
+ | | Drilling Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 1,630.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | WMGR123SW001 | ||
|- | |- | ||
| 2013-1 | | 2013-1 | ||
− | | | + | | Drilling Fluid Waste (in Barrels) |
− | | style="text-align:right;" | 635. | + | | style="text-align: right;" | 635.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
− | | | + | | Drill Cuttings (in Tons) |
− | | style="text-align:right;" | 761.48 | + | | style="text-align: right;" | 761.48 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100172 | | 100172 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Drill Cuttings (in Tons) |
− | | style="text-align:right;" | 2.21 | + | | style="text-align: right;" | 2.21 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100172 | | 100172 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-1 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 10.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-121-23995 | ||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | | style="text-align:right;" | 0.51 | + | | style="text-align: right;" | 594.86 Bbl |
− | + | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | |
+ | | WMGR123SW001 | ||
+ | |- | ||
+ | | 2014-1 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 180.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2014-1 | ||
+ | | Fracturing Fluid Waste (in Tons) | ||
+ | | style="text-align: right;" | 0.51 Tons | ||
| LANDFILL | | LANDFILL | ||
| 100172 | | 100172 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Fracturing Fluid Waste (in Tons) |
− | | style="text-align:right;" | 0.96 | + | | style="text-align: right;" | 0.96 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100663 | | 100663 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-2 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 4,134.43 Bbl | ||
+ | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
+ | | WMGR123SW001 | ||
|- | |- | ||
− | | 2014- | + | | 2014-2 |
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3,146.72 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
+ | | 2014-2 | ||
+ | | Fracturing Fluid Waste (in Tons) | ||
+ | | style="text-align: right;" | 26.65 Tons | ||
+ | | LANDFILL | ||
+ | | 100172 | ||
|- | |- | ||
− | | | + | | 2015-1 |
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2,063.86 Bbl |
− | |||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2015-1 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 292.14 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2015-1 |
− | | | + | | Fracturing Fluid Waste (in Tons) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1.47 Tons |
− | | Bbl | + | | LANDFILL |
+ | | 100419 | ||
+ | |- | ||
+ | | 2015-1 | ||
+ | | Fracturing Fluid Waste (in Tons) | ||
+ | | style="text-align: right;" | 14.39 Tons | ||
+ | | RESIDUAL WASTE TRANSFER FACILITY | ||
+ | | MID074259565 | ||
+ | |- | ||
+ | | 2015-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 157.29 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-121-23995 | | 34-121-23995 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2015-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 5,587.57 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2015-2 |
− | | | + | | Fracturing Fluid Waste (in Tons) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.23 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
− | | | + | | 073 114 654 |
− | | | + | |- |
− | | | + | | 2015-2 |
− | | | + | | Produced Fluid (in Barrels) |
+ | | style="text-align: right;" | 3,731.43 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2016-1 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 37.14 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2016-1 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 2,226.94 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
+ | | 2016-2 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 1,536.69 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | WMGR123SW019 | ||
|- | |- | ||
− | | | + | | 2016-2 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 234.01 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2017-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 30.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-059-24202 | ||
+ | |- | ||
+ | | 2017-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 176.40 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2017-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 214.89 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2017-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 125.74 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2017-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 89.66 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-04 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 54.29 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2017-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 690.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2017-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 64.29 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-157-25511 | ||
+ | |- | ||
+ | | 2017-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 35.71 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW001 | ||
|- | |- | ||
− | | | + | | 2017-06 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 17.14 Bbl |
− | | Bbl | + | | RESIDUAL WASTE PROCESSING FACILITY |
− | | RESIDUAL WASTE | + | | WMGR123SW019 |
+ | |- | ||
+ | | 2017-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 18.57 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 77.14 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-157-25511 | ||
+ | |- | ||
+ | | 2017-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 15.71 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2017-07 |
− | + | | Produced Fluid (in Barrels) RWC 802 | |
− | + | | style="text-align: right;" | 15.71 Bbl | |
− | + | | REUSE (AT WELL PAD) | |
− | + | | | |
− | + | |- | |
− | + | | 2017-08 | |
− | + | | Produced Fluid (in Barrels) RWC 802 | |
− | + | | style="text-align: right;" | 27.14 Bbl | |
− | + | | INJECTION DISPOSAL WELL | |
− | + | | 34-059-24202 | |
− | + | |- | |
− | + | | 2017-08 | |
− | + | | Produced Fluid (in Barrels) RWC 802 | |
− | + | | style="text-align: right;" | 14.29 Bbl | |
− | + | | INJECTION DISPOSAL WELL | |
+ | | 34-157-25511 | ||
+ | |- | ||
+ | | 2017-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 33.16 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2017-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 15.71 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 48.82 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 30.00 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
+ | | | ||
+ | |- | ||
+ | | 2017-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 15.03 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2017-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 17.14 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 62.86 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
+ | | | ||
+ | |- | ||
+ | | 2017-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 17.14 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-157-25511 | ||
+ | |- | ||
+ | | 2017-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 29.20 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2017-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 106.26 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2017-12 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | | + | | style="text-align: right;" | 149.43 Bbl |
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
+ | |- | ||
+ | | 2018-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 31.29 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2018-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 127.00 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
+ | |- | ||
+ | | 2018-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 16.43 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
+ | |- | ||
+ | | 2018-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 66.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2018-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 32.14 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
|- | |- | ||
+ | | 2018-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 26.43 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
+ | |- | ||
+ | | 2018-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 48.14 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2018-03 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | | + | | style="text-align: right;" | 30.71 Bbl |
− | | | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
| | | | ||
+ | |- | ||
+ | | 2018-04 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 78.71 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2018-04 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 15.71 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
|- | |- | ||
+ | | 2018-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 46.43 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
|- | |- | ||
− | | | + | | 2018-05 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | | + | | style="text-align: right;" | 32.00 Bbl |
− | | WELL | + | | REUSE (AT WELL PAD) |
| | | | ||
+ | |- | ||
+ | | 2018-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 79.29 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2018-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 27.71 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
|- | |- | ||
+ | | 2018-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 32.14 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2018-07 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | | + | | style="text-align: right;" | 47.71 Bbl |
− | | | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
| | | | ||
+ | |- | ||
+ | | 2018-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 107.71 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
+ | |- | ||
+ | | 2018-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 30.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2018-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 84.29 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2018-11 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | | + | | style="text-align: right;" | 15.71 Bbl |
− | | | + | | REUSE (AT WELL PAD) |
| | | | ||
+ | |- | ||
+ | | 2018-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 95.57 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
+ | |- | ||
+ | | 2018-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 16.43 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2018-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 80.00 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2019-01 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | | + | | style="text-align: right;" | 68.57 Bbl |
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2019-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 17.14 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2019-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 15.71 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
+ | |- | ||
+ | | 2019-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 17.14 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Waste Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
− | + | == Inspection Data == | |
− | == | + | ==== Inspections Performed ==== |
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Inspection Category |
− | !scope="col" | | + | !scope="col" | Inspection Date |
− | !scope="col" | | + | !scope="col" | Inspection Type |
− | !scope="col" | | + | !scope="col" | Inspection Result |
− | !scope="col" | | + | !scope="col" | Inspection Comments |
− | + | |- | |
+ | | 2160344 | ||
+ | | Primary Facility | ||
+ | | 03/21/2013 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2163785 | ||
+ | | Primary Facility | ||
+ | | 04/16/2013 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | KEANE 2144 DRILLING FOR CHEVRON. COULD NOT GET WATER PROTECTIVE STRING TO T.D. PULLED CASING WERE RUNNING MAG TRAP CLEANING UP HOLE. SET CASING 45' BELOW COAL. CEMENT JOB WAS GOOD. | ||
+ | |- | ||
+ | | 2185007 | ||
+ | | Primary Facility | ||
+ | | 07/12/2013 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | WELL DRILLED TO KOP. WATING FOR HORIZONTAL RIG TO MOVE IN AND COMMENCE DRILLING WELL TO COMPLETION. | ||
+ | |- | ||
+ | | 2216476 | ||
+ | | Primary Facility | ||
+ | | 10/28/2013 | ||
+ | | Administrative/File Review | ||
+ | | In Compliance with Policy | ||
+ | | On 10/25/13 operator called DEP to report spill of approx. 2 barrels of drilling mud onto secondary containment. The material was cleaned up. DCNR was also contacted about the spill, because well site is on PA Gamelands. | ||
|- | |- | ||
− | | | + | | 2334357 |
− | | | + | | Primary Facility |
− | | | + | | 10/06/2014 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | | | + | | Well being placed into production. |
− | |||
|- | |- | ||
+ | | 2356478 | ||
+ | | Primary Facility | ||
+ | | 02/24/2015 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2380286 |
− | | | + | | Primary Facility |
− | | | + | | 06/04/2015 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | | | + | | |
− | |||
|- | |- | ||
+ | | 2487910 | ||
+ | | Primary Facility | ||
+ | | 2016-05-25 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | HORIZONTAL MARCELLUS, Restoration in process. | ||
|- | |- | ||
− | | | + | | 2549792 |
− | | | + | | Primary Facility |
− | | | + | | 2016-12-08 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | | | + | | On 12/08/16 at approximately 0930 hours I conducted a routine complete inspection of the Miller Unit. The Act 9 sign was in place and all required documents were present at the site. The pad was fenced and gated. The site was well vegetated and it appeared Chevron had recently seeded and mulched a small area to the north of the access road. There was no erosion observed at the time of inspection. There were no violations observed at the time of inspection. |
− | |||
|- | |- | ||
+ | | 2623684 | ||
+ | | Primary Facility | ||
+ | | 2017-08-07 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. One location along the access road appeared to have been seeded and mulched. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. | ||
|- | |- | ||
− | | | + | | 2636978 |
− | | | + | | Primary Facility |
− | | | + | | 2017-09-15 |
− | | | + | | Site Restoration |
− | | | + | | No Violations Noted |
− | + | | A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and meets and exceeds 70% uniform vegetative cover. There were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. The site meets the requirements for permit termination. The NOT is approved. | |
− | | Chevron | ||
|- | |- | ||
+ | | 2663921 | ||
+ | | Primary Facility | ||
+ | | 2017-11-16 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. | ||
|- | |- | ||
− | | | + | | 2752953 |
− | | | + | | Primary Facility |
− | | | + | | 2018-07-17 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | | | + | | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
− | |||
|- | |- | ||
+ | |} | ||
+ | <!--==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
|- | |- | ||
− | | | + | |}--> |
− | | | + | <!--==== Penalties Applied ==== |
− | | | + | {| class="wikitable sortable" width="95%" |
− | | | + | !scope="col" | Violation ID |
− | | | + | !scope="col" | Penalty ID |
− | | | + | !scope="col" | Penalty Code |
− | | | + | !scope="col" | Penalty Status |
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
|- | |- | ||
+ | |}--> | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Compliance Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
|- | |- | ||
− | | | + | | 1 |
− | | | + | | 05/17/2014 |
− | | | + | | 05/26/2014 |
− | | | + | | style="text-align: right;" | 8074 |
− | | | + | | style="text-align: right;" | 7,548,270.0 |
− | | | + | | style="text-align: right;" | |
− | | | ||
|- | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
|- | |- | ||
− | | | + | |- valign="top" |
+ | | rowspan="16"| 1 | ||
+ | | rowspan="1"| EC6673W | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Iron Control | ||
| Ethylene Glycol | | Ethylene Glycol | ||
− | |||
− | |||
− | |||
| 107-21-1 | | 107-21-1 | ||
− | | | + | | style="text-align: right;" | 30 |
+ | | style="text-align: right;" | 0.00077143 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Proppant | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Proppant | ||
+ | | Crystalline Silica | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 9.34864 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
+ | | rowspan="1"| 15% Acid | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Perf Cleanup | ||
| Hydrocloric Acid | | Hydrocloric Acid | ||
− | |||
− | |||
− | |||
| 7647-01-0 | | 7647-01-0 | ||
− | | Schlumberger | + | | style="text-align: right;" | 15 |
+ | | style="text-align: right;" | 0.0195237 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| A264 | ||
+ | | rowspan="4"| Schlumberger | ||
+ | | rowspan="4"| Iron Control | ||
+ | | Prop-2-yn-1-ol | ||
+ | | 107-19-7 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00001100 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Aliphatic alcohols, ethoxylayed #1 | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00003300 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Aliphatic acids | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00003300 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.00004400 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="3"| EC6116A |
− | | | + | | rowspan="3"| Nalco |
− | | | + | | rowspan="3"| Biocide |
− | | | + | | 2,2-Dibromo-3-nitrilopropionamide |
− | | | + | | 10222-01-2 |
− | | | + | | style="text-align: right;" | 30 |
+ | | style="text-align: right;" | 0.00076652 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00012775 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Polyethylene Glycol |
− | | | + | | 25322-68-3 |
− | | | + | | style="text-align: right;" | 60 |
− | | | + | | style="text-align: right;" | 0.00153303 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| L058 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Iron Stabilizer | ||
+ | | Sodium erythorbate | ||
+ | | 6381-77-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00035487 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| J134 |
− | | | + | | rowspan="1"| Schlumberger |
− | | | + | | rowspan="1"| Gel Breaker |
− | | | + | | Hemicellulase Enzyme |
− | | | + | | 9012-54-8 |
− | | | + | | style="text-align: right;" | 100 |
+ | | style="text-align: right;" | 0.00103048 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| J609 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Ammonium Sulfate | ||
+ | | 7783-20-2 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00377313 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | 1 | + | |- valign="top" |
− | | | + | | rowspan="1"| Base Fluid |
− | | | + | | rowspan="1"| Chevron |
− | | | + | | rowspan="1"| Carrier/Base Fluid |
− | | | + | | Water (Including Mix Water Supplied by Client) |
− | | | + | | 7732-18-5 |
− | | | + | | style="text-align: right;" | 100 |
+ | | style="text-align: right;" | 90.4785 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6486A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000811894 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| J580 |
− | | | + | | rowspan="1"| Schlumberger |
− | | | + | | rowspan="1"| Gelling Agent |
− | | | + | | Carboydrate polymer |
| Proprietary | | Proprietary | ||
− | | | + | | style="text-align: right;" | 100 |
+ | | style="text-align: right;" | 0.0207951 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
− | For data sources see<ref>{{cite web | title = FracFocus | + | For data sources see<ref>{{cite web |
− | == References == | + | | title =FracFocus Fracking Chemicals Database |
− | + | | date = 2019-04-02 | |
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
+ | ==References== | ||
+ | <references/> | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 37-059-26113 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.785089,"lon":-80.028936,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Dunkard Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 144823 | |
Farm/Lease Name: MILLER UNIT 77H | |
License Status: Active | |
Spud Date: 03/19/2013 | |
Permit Date: 2/27/2013 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.785089 | |
Longitude: -80.028936 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 56,028.00 | 36 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 1,338,576.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 873,247.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 673,921.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 558,288.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 123,110.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2013-1 | Drill Cuttings (in Tons) | 354.61 Tons | LANDFILL | 100419 |
2013-1 | Drilling Fluid Waste (in Barrels) | 1,630.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013-1 | Drilling Fluid Waste (in Barrels) | 635.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-2 | Drill Cuttings (in Tons) | 761.48 Tons | LANDFILL | 100172 |
2014-1 | Drill Cuttings (in Tons) | 2.21 Tons | LANDFILL | 100172 |
2014-1 | Fracing Fluid Waste (in Barrels) | 10.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014-1 | Fracing Fluid Waste (in Barrels) | 594.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-1 | Fracing Fluid Waste (in Barrels) | 180.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Fracturing Fluid Waste (in Tons) | 0.51 Tons | LANDFILL | 100172 |
2014-1 | Fracturing Fluid Waste (in Tons) | 0.96 Tons | LANDFILL | 100663 |
2014-2 | Fracing Fluid Waste (in Barrels) | 4,134.43 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-2 | Fracing Fluid Waste (in Barrels) | 3,146.72 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Fracturing Fluid Waste (in Tons) | 26.65 Tons | LANDFILL | 100172 |
2015-1 | Fracing Fluid Waste (in Barrels) | 2,063.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-1 | Fracing Fluid Waste (in Barrels) | 292.14 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Fracturing Fluid Waste (in Tons) | 1.47 Tons | LANDFILL | 100419 |
2015-1 | Fracturing Fluid Waste (in Tons) | 14.39 Tons | RESIDUAL WASTE TRANSFER FACILITY | MID074259565 |
2015-1 | Produced Fluid (in Barrels) | 157.29 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2015-1 | Produced Fluid (in Barrels) | 5,587.57 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Fracturing Fluid Waste (in Tons) | 0.23 Tons | LANDFILL | 073 114 654 |
2015-2 | Produced Fluid (in Barrels) | 3,731.43 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 37.14 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 2,226.94 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 1,536.69 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 234.01 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 30.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 176.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 214.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 125.74 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 89.66 Bbl | REUSE (AT WELL PAD) | |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 54.29 Bbl | REUSE (AT WELL PAD) | |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 690.00 Bbl | REUSE (AT WELL PAD) | |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 64.29 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 35.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 17.14 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 18.57 Bbl | REUSE (AT WELL PAD) | |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 77.14 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 15.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 15.71 Bbl | REUSE (AT WELL PAD) | |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 27.14 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 14.29 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 33.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 15.71 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 48.82 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 30.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 15.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 17.14 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 62.86 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 17.14 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 29.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 106.26 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 149.43 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 31.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 127.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 16.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 66.00 Bbl | REUSE (AT WELL PAD) | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 32.14 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 26.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 48.14 Bbl | REUSE (AT WELL PAD) | |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 30.71 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 78.71 Bbl | REUSE (AT WELL PAD) | |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 15.71 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 46.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 32.00 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 79.29 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 27.71 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 32.14 Bbl | REUSE (AT WELL PAD) | |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 47.71 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 107.71 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 30.00 Bbl | REUSE (AT WELL PAD) | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 84.29 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 15.71 Bbl | REUSE (AT WELL PAD) | |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 95.57 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 16.43 Bbl | REUSE (AT WELL PAD) | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 80.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 68.57 Bbl | REUSE (AT WELL PAD) | |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 17.14 Bbl | REUSE (AT WELL PAD) | |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 15.71 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 17.14 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2160344 | Primary Facility | 03/21/2013 | Routine/Complete Inspection | No Violations Noted | |
2163785 | Primary Facility | 04/16/2013 | Drilling/Alteration | No Violations Noted | KEANE 2144 DRILLING FOR CHEVRON. COULD NOT GET WATER PROTECTIVE STRING TO T.D. PULLED CASING WERE RUNNING MAG TRAP CLEANING UP HOLE. SET CASING 45' BELOW COAL. CEMENT JOB WAS GOOD. |
2185007 | Primary Facility | 07/12/2013 | Drilling/Alteration | No Violations Noted | WELL DRILLED TO KOP. WATING FOR HORIZONTAL RIG TO MOVE IN AND COMMENCE DRILLING WELL TO COMPLETION. |
2216476 | Primary Facility | 10/28/2013 | Administrative/File Review | In Compliance with Policy | On 10/25/13 operator called DEP to report spill of approx. 2 barrels of drilling mud onto secondary containment. The material was cleaned up. DCNR was also contacted about the spill, because well site is on PA Gamelands. |
2334357 | Primary Facility | 10/06/2014 | Routine/Complete Inspection | No Violations Noted | Well being placed into production. |
2356478 | Primary Facility | 02/24/2015 | Routine/Complete Inspection | No Violations Noted | |
2380286 | Primary Facility | 06/04/2015 | Routine/Complete Inspection | No Violations Noted | |
2487910 | Primary Facility | 2016-05-25 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, Restoration in process. |
2549792 | Primary Facility | 2016-12-08 | Routine/Complete Inspection | No Violations Noted | On 12/08/16 at approximately 0930 hours I conducted a routine complete inspection of the Miller Unit. The Act 9 sign was in place and all required documents were present at the site. The pad was fenced and gated. The site was well vegetated and it appeared Chevron had recently seeded and mulched a small area to the north of the access road. There was no erosion observed at the time of inspection. There were no violations observed at the time of inspection. |
2623684 | Primary Facility | 2017-08-07 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. One location along the access road appeared to have been seeded and mulched. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2636978 | Primary Facility | 2017-09-15 | Site Restoration | No Violations Noted | A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and meets and exceeds 70% uniform vegetative cover. There were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. The site meets the requirements for permit termination. The NOT is approved. |
2663921 | Primary Facility | 2017-11-16 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2752953 | Primary Facility | 2018-07-17 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 05/17/2014 | 05/26/2014 | 8074 | 7,548,270.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | EC6673W | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30 | 0.00077143 | 0 |
Proppant | Schlumberger | Proppant | Crystalline Silica | 14808-60-7 | 100 | 9.34864 | 0 | |
15% Acid | Schlumberger | Perf Cleanup | Hydrocloric Acid | 7647-01-0 | 15 | 0.0195237 | 0 | |
A264 | Schlumberger | Iron Control | Prop-2-yn-1-ol | 107-19-7 | 10 | 0.00001100 | 0 | |
Aliphatic alcohols, ethoxylayed #1 | Proprietary | 30 | 0.00003300 | 0 | ||||
Aliphatic acids | Proprietary | 30 | 0.00003300 | 0 | ||||
Methanol | 67-56-1 | 40 | 0.00004400 | 0 | ||||
EC6116A | Nalco | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00076652 | 0 | |
Dibromoacetonitrile | 3252-43-5 | 5 | 0.00012775 | 0 | ||||
Polyethylene Glycol | 25322-68-3 | 60 | 0.00153303 | 0 | ||||
L058 | Schlumberger | Iron Stabilizer | Sodium erythorbate | 6381-77-7 | 100 | 0.00035487 | 0 | |
J134 | Schlumberger | Gel Breaker | Hemicellulase Enzyme | 9012-54-8 | 100 | 0.00103048 | 0 | |
J609 | Schlumberger | Friction Reducer | Ammonium Sulfate | 7783-20-2 | 30 | 0.00377313 | 0 | |
Base Fluid | Chevron | Carrier/Base Fluid | Water (Including Mix Water Supplied by Client) | 7732-18-5 | 100 | 90.4785 | 0 | |
EC6486A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.000811894 | 0 | |
J580 | Schlumberger | Gelling Agent | Carboydrate polymer | Proprietary | 100 | 0.0207951 | 0 |
For data sources see[7]