If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-059-26290 | | Well ID: 37-059-26290 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39.936758, -80.156225 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 04 | + | | Spud Date: 2014-04-24 |
|- | |- | ||
− | | Permit Date: 11 | + | | Permit Date: 2013-11-22 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2015-01-02 | ||
+ | | 2015-01-22 | ||
+ | | style="text-align: right;" | 8086 | ||
+ | | style="text-align: right;" | 8,917,000.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="18"| 1 | ||
+ | | rowspan="1"| 15% Acid | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Perf Cleanup | ||
+ | | Hydrocloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.0113265 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| L058 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Iron Stabilizer | ||
+ | | Sodium erythorbate | ||
+ | | 6381-77-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00068068 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| J134 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Gel Breaker | ||
+ | | Hemicellulase enzyme | ||
+ | | 9012-54-8 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00176508 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| A264 | ||
+ | | rowspan="4"| Schlumberger | ||
+ | | rowspan="4"| Corrosion Inhibitor | ||
+ | | Aliphatic acids | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00003798 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Aliphatic alcohols, ethoxylayed #1 | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00003798 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Prop-2-yn-1-ol | ||
+ | | 107-19-7 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00001266 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.00005064 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| B466 | ||
+ | | rowspan="3"| Schlumberger | ||
+ | | rowspan="3"| Friction Reducer | ||
+ | | Distillates (petroleum), hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00313933 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Ammonium Acetate | ||
+ | | 631-61-8 | ||
+ | | style="text-align: right;" | 6 | ||
+ | | style="text-align: right;" | 0.00062787 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Alcohol Ethoxylates | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00052322 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| EC6116A | ||
+ | | rowspan="3"| Nalco | ||
+ | | rowspan="3"| Biocide | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00073176 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Polyethylene Glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00146351 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00012196 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6486A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0007846 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Proppant | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Proppant | ||
+ | | Crystalline Silica | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 11.1195 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Base Fluid | ||
+ | | rowspan="1"| Chevron | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water (Including Mix Water Supplied by Client) | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 88.6851 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| J580 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Gelling Agent, Water | ||
+ | | Carbohydrate Polymer | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.0323934 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6673W | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Iron Control | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00073176 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 129: | Line 318: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 177.26 Tons | | style="text-align: right;" | 177.26 Tons | ||
Line 135: | Line 324: | ||
| 100172 | | 100172 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 65.88 Tons | | style="text-align: right;" | 65.88 Tons | ||
Line 141: | Line 330: | ||
| 100419 | | 100419 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 1,072.00 Bbl | | style="text-align: right;" | 1,072.00 Bbl | ||
Line 147: | Line 336: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 396.00 Bbl | | style="text-align: right;" | 396.00 Bbl | ||
Line 153: | Line 342: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 133.34 Tons | | style="text-align: right;" | 133.34 Tons | ||
Line 159: | Line 348: | ||
| 100172 | | 100172 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 562.69 Tons | | style="text-align: right;" | 562.69 Tons | ||
Line 165: | Line 354: | ||
| 100419 | | 100419 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 8.77 Tons | | style="text-align: right;" | 8.77 Tons | ||
Line 171: | Line 360: | ||
| 100592 | | 100592 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 372.00 Bbl | | style="text-align: right;" | 372.00 Bbl | ||
Line 177: | Line 366: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 84.00 Bbl | | style="text-align: right;" | 84.00 Bbl | ||
Line 183: | Line 372: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 742.60 Bbl | | style="text-align: right;" | 742.60 Bbl | ||
Line 189: | Line 378: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 1,759.80 Bbl | | style="text-align: right;" | 1,759.80 Bbl | ||
Line 195: | Line 384: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 54.00 Bbl | | style="text-align: right;" | 54.00 Bbl | ||
Line 201: | Line 390: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 24.90 Tons | | style="text-align: right;" | 24.90 Tons | ||
Line 207: | Line 396: | ||
| 100172 | | 100172 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 0.77 Tons | | style="text-align: right;" | 0.77 Tons | ||
Line 213: | Line 402: | ||
| 100277 | | 100277 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 8.63 Tons | | style="text-align: right;" | 8.63 Tons | ||
Line 219: | Line 408: | ||
| 100592 | | 100592 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 18.69 Tons | | style="text-align: right;" | 18.69 Tons | ||
Line 225: | Line 414: | ||
| 101532 | | 101532 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 137.00 Bbl | | style="text-align: right;" | 137.00 Bbl | ||
Line 231: | Line 420: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 1.24 Tons | | style="text-align: right;" | 1.24 Tons | ||
Line 237: | Line 426: | ||
| 100663 | | 100663 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 562.00 Bbl | | style="text-align: right;" | 562.00 Bbl | ||
Line 243: | Line 432: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 8,642.20 Bbl | | style="text-align: right;" | 8,642.20 Bbl | ||
Line 249: | Line 438: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 0.23 Tons | | style="text-align: right;" | 0.23 Tons | ||
Line 255: | Line 444: | ||
| 100592 | | 100592 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 59.00 Bbl | | style="text-align: right;" | 59.00 Bbl | ||
Line 261: | Line 450: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 13,886.00 Bbl | | style="text-align: right;" | 13,886.00 Bbl | ||
Line 267: | Line 456: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-S01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 49.00 Bbl | | style="text-align: right;" | 49.00 Bbl | ||
Line 273: | Line 462: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 7,029.67 Bbl | | style="text-align: right;" | 7,029.67 Bbl | ||
Line 279: | Line 468: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 4,025.00 Bbl | | style="text-align: right;" | 4,025.00 Bbl | ||
Line 285: | Line 474: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 699.43 Bbl | | style="text-align: right;" | 699.43 Bbl | ||
Line 291: | Line 480: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | ||
| style="text-align: right;" | 0.15 Tons | | style="text-align: right;" | 0.15 Tons | ||
Line 297: | Line 486: | ||
| 101532 | | 101532 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 51.40 Bbl | | style="text-align: right;" | 51.40 Bbl | ||
Line 303: | Line 492: | ||
| 34-059-24202 | | 34-059-24202 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 562.11 Bbl | | style="text-align: right;" | 562.11 Bbl | ||
Line 309: | Line 498: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 500.56 Bbl | | style="text-align: right;" | 500.56 Bbl | ||
Line 315: | Line 504: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 26.00 Bbl | | style="text-align: right;" | 26.00 Bbl | ||
Line 321: | Line 510: | ||
| 34-059-24202 | | 34-059-24202 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 203.23 Bbl | | style="text-align: right;" | 203.23 Bbl | ||
Line 327: | Line 516: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 201.40 Bbl | | style="text-align: right;" | 201.40 Bbl | ||
Line 333: | Line 522: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 125.00 Bbl | | style="text-align: right;" | 125.00 Bbl | ||
Line 339: | Line 528: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1,008.00 Bbl | | style="text-align: right;" | 1,008.00 Bbl | ||
Line 345: | Line 534: | ||
| 34-157-25511 | | 34-157-25511 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 924.00 Bbl | | style="text-align: right;" | 924.00 Bbl | ||
Line 351: | Line 540: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 297.20 Bbl | | style="text-align: right;" | 297.20 Bbl | ||
Line 357: | Line 546: | ||
| 34-157-25511 | | 34-157-25511 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 145.00 Bbl | | style="text-align: right;" | 145.00 Bbl | ||
Line 363: | Line 552: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 369: | Line 558: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 257.00 Bbl | | style="text-align: right;" | 257.00 Bbl | ||
Line 375: | Line 564: | ||
| 34-157-25511 | | 34-157-25511 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 110.00 Bbl | | style="text-align: right;" | 110.00 Bbl | ||
Line 381: | Line 570: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 20.00 Bbl | | style="text-align: right;" | 20.00 Bbl | ||
Line 387: | Line 576: | ||
| 34-059-24202 | | 34-059-24202 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 54.00 Bbl | | style="text-align: right;" | 54.00 Bbl | ||
Line 393: | Line 582: | ||
| 34-157-25511 | | 34-157-25511 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 42.67 Bbl | | style="text-align: right;" | 42.67 Bbl | ||
Line 399: | Line 588: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 239.00 Bbl | | style="text-align: right;" | 239.00 Bbl | ||
Line 405: | Line 594: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 334.20 Bbl | | style="text-align: right;" | 334.20 Bbl | ||
Line 411: | Line 600: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 44.00 Bbl | | style="text-align: right;" | 44.00 Bbl | ||
Line 417: | Line 606: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 21.76 Bbl | | style="text-align: right;" | 21.76 Bbl | ||
Line 423: | Line 612: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 92.00 Bbl | | style="text-align: right;" | 92.00 Bbl | ||
Line 429: | Line 618: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 126.00 Bbl | | style="text-align: right;" | 126.00 Bbl | ||
Line 435: | Line 624: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 87.42 Bbl | | style="text-align: right;" | 87.42 Bbl | ||
Line 441: | Line 630: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 288.99 Bbl | | style="text-align: right;" | 288.99 Bbl | ||
Line 447: | Line 636: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 54.83 Bbl | | style="text-align: right;" | 54.83 Bbl | ||
Line 453: | Line 642: | ||
| 34-119-28776 | | 34-119-28776 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 24.62 Bbl | | style="text-align: right;" | 24.62 Bbl | ||
Line 459: | Line 648: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 383.00 Bbl | | style="text-align: right;" | 383.00 Bbl | ||
Line 465: | Line 654: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 66.24 Bbl | | style="text-align: right;" | 66.24 Bbl | ||
Line 471: | Line 660: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.18 Bbl | | style="text-align: right;" | 22.18 Bbl | ||
Line 477: | Line 666: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 266.40 Bbl | | style="text-align: right;" | 266.40 Bbl | ||
Line 483: | Line 672: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 24.00 Bbl | | style="text-align: right;" | 24.00 Bbl | ||
Line 489: | Line 678: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 91.00 Bbl | | style="text-align: right;" | 91.00 Bbl | ||
Line 495: | Line 684: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 136.40 Bbl | | style="text-align: right;" | 136.40 Bbl | ||
Line 501: | Line 690: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 110.40 Bbl | | style="text-align: right;" | 110.40 Bbl | ||
Line 507: | Line 696: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 89.22 Bbl | | style="text-align: right;" | 89.22 Bbl | ||
Line 513: | Line 702: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 519: | Line 708: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 196.20 Bbl | | style="text-align: right;" | 196.20 Bbl | ||
Line 525: | Line 714: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 46.40 Bbl | | style="text-align: right;" | 46.40 Bbl | ||
Line 531: | Line 720: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 42.67 Bbl | | style="text-align: right;" | 42.67 Bbl | ||
Line 537: | Line 726: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 84.00 Bbl | | style="text-align: right;" | 84.00 Bbl | ||
Line 543: | Line 732: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 111.00 Bbl | | style="text-align: right;" | 111.00 Bbl | ||
Line 549: | Line 738: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 200.60 Bbl | | style="text-align: right;" | 200.60 Bbl | ||
Line 555: | Line 744: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 69.00 Bbl | | style="text-align: right;" | 69.00 Bbl | ||
Line 561: | Line 750: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 0.20 Bbl | | style="text-align: right;" | 0.20 Bbl | ||
Line 567: | Line 756: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 573: | Line 762: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 65.00 Bbl | | style="text-align: right;" | 65.00 Bbl | ||
Line 579: | Line 768: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 62.00 Bbl | | style="text-align: right;" | 62.00 Bbl | ||
Line 585: | Line 774: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 44.80 Bbl | | style="text-align: right;" | 44.80 Bbl | ||
Line 591: | Line 780: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 199.60 Bbl | | style="text-align: right;" | 199.60 Bbl | ||
Line 597: | Line 786: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 376.40 Bbl | | style="text-align: right;" | 376.40 Bbl | ||
Line 603: | Line 792: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 65.00 Bbl | | style="text-align: right;" | 65.00 Bbl | ||
Line 609: | Line 798: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 393.00 Bbl | | style="text-align: right;" | 393.00 Bbl | ||
Line 615: | Line 804: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 564.00 Bbl | | style="text-align: right;" | 564.00 Bbl | ||
Line 621: | Line 810: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 3,473.00 Bbl | | style="text-align: right;" | 3,473.00 Bbl | ||
Line 627: | Line 816: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 44.00 Bbl | | style="text-align: right;" | 44.00 Bbl | ||
Line 633: | Line 822: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 605.00 Bbl | | style="text-align: right;" | 605.00 Bbl | ||
Line 639: | Line 828: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 645: | Line 834: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 409.20 Bbl | | style="text-align: right;" | 409.20 Bbl | ||
Line 651: | Line 840: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 250.00 Bbl | | style="text-align: right;" | 250.00 Bbl | ||
Line 657: | Line 846: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 72.00 Bbl | | style="text-align: right;" | 72.00 Bbl | ||
Line 663: | Line 852: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 158.00 Bbl | | style="text-align: right;" | 158.00 Bbl | ||
Line 669: | Line 858: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 675: | Line 864: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 324.00 Bbl | | style="text-align: right;" | 324.00 Bbl | ||
Line 700: | Line 889: | ||
| 2281382 | | 2281382 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2014-06-24 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 707: | Line 896: | ||
| 2291960 | | 2291960 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2014-07-15 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 714: | Line 903: | ||
| 2292006 | | 2292006 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2014-07-30 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 721: | Line 910: | ||
| 2298796 | | 2298796 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2014-07-14 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 728: | Line 917: | ||
| 2329934 | | 2329934 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2014-12-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 735: | Line 924: | ||
| 2331547 | | 2331547 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2014-12-23 |
| Complaint Inspection | | Complaint Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 742: | Line 931: | ||
| 2379371 | | 2379371 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2015-03-31 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 749: | Line 938: | ||
| 2398582 | | 2398582 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2015-07-07 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 810: | Line 999: | ||
| 712593 | | 712593 | ||
| 12/10/2014 | | 12/10/2014 | ||
− | | | + | | 2014-12-10 |
| 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. | | 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. | ||
| Administrative | | Administrative | ||
Line 832: | Line 1,021: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 06 | + | | 2015-06-23 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 843: | Line 1,032: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-059-26290 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.936758,"lon":-80.156225,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Franklin Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 150363 | |
Farm/Lease Name: BEDILION UNIT 1H | |
License Status: Active | |
Spud Date: 2014-04-24 | |
Permit Date: 2013-11-22 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.936758 | |
Longitude: -80.156225 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-01-02 | 2015-01-22 | 8086 | 8,917,000.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | 15% Acid | Schlumberger | Perf Cleanup | Hydrocloric Acid | 7647-01-0 | 15 | 0.0113265 | 0 |
L058 | Schlumberger | Iron Stabilizer | Sodium erythorbate | 6381-77-7 | 100 | 0.00068068 | 0 | |
J134 | Schlumberger | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 100 | 0.00176508 | 0 | |
A264 | Schlumberger | Corrosion Inhibitor | Aliphatic acids | Proprietary | 30 | 0.00003798 | 0 | |
Aliphatic alcohols, ethoxylayed #1 | Proprietary | 30 | 0.00003798 | 0 | ||||
Prop-2-yn-1-ol | 107-19-7 | 10 | 0.00001266 | 0 | ||||
Methanol | 67-56-1 | 40 | 0.00005064 | 0 | ||||
B466 | Schlumberger | Friction Reducer | Distillates (petroleum), hydrotreated light | 64742-47-8 | 30 | 0.00313933 | 0 | |
Ammonium Acetate | 631-61-8 | 6 | 0.00062787 | 0 | ||||
Alcohol Ethoxylates | Proprietary | 5 | 0.00052322 | 0 | ||||
EC6116A | Nalco | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00073176 | 0 | |
Polyethylene Glycol | 25322-68-3 | 60 | 0.00146351 | 0 | ||||
Dibromoacetonitrile | 3252-43-5 | 5 | 0.00012196 | 0 | ||||
EC6486A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.0007846 | 0 | |
Proppant | Schlumberger | Proppant | Crystalline Silica | 14808-60-7 | 100 | 11.1195 | 0 | |
Base Fluid | Chevron | Carrier/Base Fluid | Water (Including Mix Water Supplied by Client) | 7732-18-5 | 100 | 88.6851 | 0 | |
J580 | Schlumberger | Gelling Agent, Water | Carbohydrate Polymer | Proprietary | 100 | 0.0323934 | 0 | |
EC6673W | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30 | 0.00073176 | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 1,316,888.00 | 198 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 1,458,310.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 956,576.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 567,290.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 136,993.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2014-S01 | Drill Cuttings (in Tons) | 177.26 Tons | LANDFILL | 100172 |
2014-S01 | Drill Cuttings (in Tons) | 65.88 Tons | LANDFILL | 100419 |
2014-S01 | Drilling Fluid Waste (in Barrels) | 1,072.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S01 | Fracing Fluid Waste (in Barrels) | 396.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Drill Cuttings (in Tons) | 133.34 Tons | LANDFILL | 100172 |
2014-S02 | Drill Cuttings (in Tons) | 562.69 Tons | LANDFILL | 100419 |
2014-S02 | Drill Cuttings (in Tons) | 8.77 Tons | LANDFILL | 100592 |
2014-S02 | Drilling Fluid Waste (in Barrels) | 372.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S02 | Drilling Fluid Waste (in Barrels) | 84.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Fracing Fluid Waste (in Barrels) | 742.60 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S01 | Fracing Fluid Waste (in Barrels) | 1,759.80 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S01 | Fracing Fluid Waste (in Barrels) | 54.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Fracturing Fluid Waste (in Tons) | 24.90 Tons | LANDFILL | 100172 |
2015-S01 | Fracturing Fluid Waste (in Tons) | 0.77 Tons | LANDFILL | 100277 |
2015-S01 | Fracturing Fluid Waste (in Tons) | 8.63 Tons | LANDFILL | 100592 |
2015-S01 | Fracturing Fluid Waste (in Tons) | 18.69 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2015-S01 | Produced Fluid (in Barrels) | 137.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Drill Cuttings (in Tons) | 1.24 Tons | LANDFILL | 100663 |
2015-S02 | Fracing Fluid Waste (in Barrels) | 562.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S02 | Fracing Fluid Waste (in Barrels) | 8,642.20 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Fracturing Fluid Waste (in Tons) | 0.23 Tons | LANDFILL | 100592 |
2015-S02 | Produced Fluid (in Barrels) | 59.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S02 | Produced Fluid (in Barrels) | 13,886.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 49.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 7,029.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 4,025.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 699.43 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 0.15 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 51.40 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 562.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 500.56 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 26.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 203.23 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 201.40 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 125.00 Bbl | REUSE (AT WELL PAD) | |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 1,008.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 924.00 Bbl | REUSE (AT WELL PAD) | |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 297.20 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 145.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 257.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 20.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 54.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 42.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 239.00 Bbl | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 334.20 Bbl | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 44.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 21.76 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 92.00 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 126.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 87.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 288.99 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 54.83 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 24.62 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 383.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 66.24 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 22.18 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 266.40 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 24.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 91.00 Bbl | REUSE (AT WELL PAD) | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 136.40 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 110.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 89.22 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 196.20 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 46.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 42.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 84.00 Bbl | REUSE (AT WELL PAD) | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 111.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 200.60 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 69.00 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 0.20 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 62.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 44.80 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 199.60 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 376.40 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 393.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 564.00 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 3,473.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 44.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 605.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 409.20 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 250.00 Bbl | REUSE (AT WELL PAD) | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 72.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 158.00 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 324.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2281382 | Primary Facility | 2014-06-24 | Drilling/Alteration | No Violations Noted | Drilling @ 400'; walked location; containment and cuttings good; no issues on rig; |
2291960 | Primary Facility | 2014-07-15 | Drilling/Alteration | No Violations Noted | Drilled to 2630'TD; pulling out drill pipe and preparing to run 8 5/8" |
2292006 | Primary Facility | 2014-07-30 | Drilling/Alteration | No Violations Noted | Nabors X09 rig drilled to 2630'TD; Set 8 5/8" at 2612; cement with 587 sks Class A with easy bloc; 22 bbls of cement returns; Presently drilling @ 14800'; Walked location and spotted several areas of standing water with slight sheen; Company man to vacuum ASAP; |
2298796 | Primary Facility | 2014-07-14 | Routine/Complete Inspection | No Violations Noted | Well in compliance. |
2329934 | Primary Facility | 2014-12-10 | Routine/Complete Inspection | Violation(s) Noted | |
2331547 | Primary Facility | 2014-12-23 | Complaint Inspection | No Violations Noted | Frac job underway. |
2379371 | Primary Facility | 2015-03-31 | Routine/Complete Inspection | No Violations Noted | Well drilled fracked. Operations on going to place well into production. |
2398582 | Primary Facility | 2015-07-07 | Routine/Complete Inspection | No Violations Noted | |
2530851 | Primary Facility | 2016-10-07 | Site Restoration | No Violations Noted | An inspection conducted in response to a notice of termination request by the operator. |
2570918 | Primary Facility | 2017-03-13 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was partially snow-covered but appeared to be well vegetated. There were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2598319 | Primary Facility | 2017-05-08 | Routine/Complete Inspection | No Violations Noted | An inspection was conducted in response to a well site restoration report being submitted by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was found to be restored and well vegetated. There were no violations observed at the time of inspection. |
2630366 | Primary Facility | 2017-07-27 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. At Chevron's request, Department Water Quality and Oil and Gas Inspector staff met with Chevron representatives to demonstrate a site inspection. The site was well vegetated and there were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2670270 | Primary Facility | 2017-12-11 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2786601 | Primary Facility | 2018-10-10 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2329934 | 712593 | 12/10/2014 | 2014-12-10 | 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
712593 | 318423 | NOV - Notice of Violation | Comply/Closed | 2015-06-23 |
For data sources see[7]