X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-059-26315"

m
m
Line 278: Line 278:
 
|-
 
|-
 
| 2018
 
| 2018
| [[ENERGY CORP OF AMER]]
+
| [[GREYLOCK PROD LLC]]
 
| style="text-align: right;" | 517,248.00
 
| style="text-align: right;" | 517,248.00
 
| style="text-align: right;" | 334
 
| style="text-align: right;" | 334
Line 305: Line 305:
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Period
 
!scope="col" | Period
 +
!scope="col" | Operator
 
!scope="col" | Waste Type
 
!scope="col" | Waste Type
 
!scope="col" | Quantity
 
!scope="col" | Quantity
Line 310: Line 311:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2014-S01
+
| 2014
 +
| [[ENERGY CORP OF AMER]]
 +
| Drill Cuttings (in Tons)
 +
| style="text-align: right;" | 356.06 Tons
 +
| LANDFILL
 +
| 100277
 +
|-
 +
| 2014
 +
| [[ENERGY CORP OF AMER]]
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 502.90 Tons
 
| style="text-align: right;" | 502.90 Tons
Line 316: Line 325:
 
| 100419
 
| 100419
 
|-
 
|-
| 2014-S02
+
| 2014
| Drill Cuttings (in Tons)
+
| [[ENERGY CORP OF AMER]]
| style="text-align: right;" | 356.06 Tons
+
| General O&G waste not covered by other waste types
 +
| style="text-align: right;" | 8.15 Tons
 +
| LANDFILL
 +
| 100419
 +
|-
 +
| 2014
 +
| [[ENERGY CORP OF AMER]]
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 8.73 Tons
 
| LANDFILL
 
| LANDFILL
 
| 100277
 
| 100277
 
|-
 
|-
| 2014-S02
+
| 2014
 +
| [[ENERGY CORP OF AMER]]
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 13,245.00 Bbl
 
| style="text-align: right;" | 13,245.00 Bbl
Line 328: Line 346:
 
|  
 
|  
 
|-
 
|-
| 2014-S02
+
| 2015
 +
| [[ENERGY CORP OF AMER]]
 
| Fracturing Fluid Waste (in Tons)
 
| Fracturing Fluid Waste (in Tons)
| style="text-align: right;" | 8.73 Tons
+
| style="text-align: right;" | 2.27 Tons
 
| LANDFILL
 
| LANDFILL
| 100277
+
| 100419
 
|-
 
|-
| 2014-S02
+
| 2015
| General O&G waste not covered by other waste types
+
| [[ENERGY CORP OF AMER]]
| style="text-align: right;" | 8.15 Tons
+
| Produced Fluid (in Barrels)
| LANDFILL
+
| style="text-align: right;" | 237.00 Bbl
| 100419
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW019
 
|-
 
|-
| 2015-S01
+
| 2015
 +
| [[ENERGY CORP OF AMER]]
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 222.78 Tons
 
| style="text-align: right;" | 222.78 Tons
Line 346: Line 367:
 
| 100419
 
| 100419
 
|-
 
|-
| 2015-S01
+
| 2015
| Fracing Fluid Waste (in Barrels)
+
| [[ENERGY CORP OF AMER]]
| style="text-align: right;" | 29,068.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2015-S01
 
 
| Fracturing Fluid Waste (in Tons)
 
| Fracturing Fluid Waste (in Tons)
| style="text-align: right;" | 43.66 Tons
+
| style="text-align: right;" | 22.16 Tons
 
| LANDFILL
 
| LANDFILL
| 100277
+
| 100172
 
|-
 
|-
| 2015-S01
+
| 2015
| Fracturing Fluid Waste (in Tons)
+
| [[ENERGY CORP OF AMER]]
| style="text-align: right;" | 2.27 Tons
+
| Produced Fluid (in Barrels)
| LANDFILL
+
| style="text-align: right;" | 810.00 Bbl
| 100419
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW010
 
|-
 
|-
| 2015-S01
+
| 2015
 +
| [[ENERGY CORP OF AMER]]
 
| General O&G waste not covered by other waste types
 
| General O&G waste not covered by other waste types
 
| style="text-align: right;" | 6.41 Tons
 
| style="text-align: right;" | 6.41 Tons
Line 370: Line 388:
 
| 100419
 
| 100419
 
|-
 
|-
| 2015-S01
+
| 2015
 +
| [[ENERGY CORP OF AMER]]
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 0.27 Tons
 +
| LANDFILL
 +
| 100594
 +
|-
 +
| 2015
 +
| [[ENERGY CORP OF AMER]]
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 43.66 Tons
 +
| LANDFILL
 +
| 100277
 +
|-
 +
| 2015
 +
| [[ENERGY CORP OF AMER]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 8,394.00 Bbl
+
| style="text-align: right;" | 11,742.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-S02
+
| 2015
| Fracturing Fluid Waste (in Tons)
+
| [[ENERGY CORP OF AMER]]
| style="text-align: right;" | 22.16 Tons
 
| LANDFILL
 
| 100172
 
|-
 
| 2015-S02
 
 
| Fracturing Fluid Waste (in Tons)
 
| Fracturing Fluid Waste (in Tons)
 
| style="text-align: right;" | 9.76 Tons
 
| style="text-align: right;" | 9.76 Tons
Line 388: Line 416:
 
| 100280
 
| 100280
 
|-
 
|-
| 2015-S02
+
| 2015
| Fracturing Fluid Waste (in Tons)
+
| [[ENERGY CORP OF AMER]]
| style="text-align: right;" | 0.27 Tons
+
| Fracing Fluid Waste (in Barrels)
| LANDFILL
+
| style="text-align: right;" | 29,068.00 Bbl
| 100594
+
| REUSE OTHER THAN ROAD SPREADING
 +
|  
 
|-
 
|-
| 2015-S02
+
| 2015
| Produced Fluid (in Barrels)
+
| [[ENERGY CORP OF AMER]]
| style="text-align: right;" | 237.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW019
 
|-
 
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 411.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 2D0859721
 
|-
 
| 2015-S02
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 200.00 Bbl
 
| style="text-align: right;" | 200.00 Bbl
Line 412: Line 430:
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
| 2015-S02
+
| 2015
 +
| [[ENERGY CORP OF AMER]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 810.00 Bbl
+
| style="text-align: right;" | 411.00 Bbl
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123SW010
 
|-
 
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 3,348.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 2,050.00 Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-167-29543
+
| 2D0859721
 
|-
 
|-
| 2016-S02
+
| 2016
| Produced Fluid (in Barrels) RWC 802
+
| [[ENERGY CORP OF AMER]]
| style="text-align: right;" | 108.00 Bbl
 
| CENT WASTE TRT FAC NPDES DISCHARGE
 
| WVR00521948
 
|-
 
| 2016-S02
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 265.00 Bbl
 
| style="text-align: right;" | 265.00 Bbl
Line 442: Line 444:
 
| 2D0859721
 
| 2D0859721
 
|-
 
|-
| 2016-S02
+
| 2016
 +
| [[ENERGY CORP OF AMER]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 94.00 Bbl
+
| style="text-align: right;" | 2,050.00 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| INJECTION DISPOSAL WELL
| WMGR123SW010
+
| 34-167-29543
 
|-
 
|-
| 2016-S02
+
| 2016
 +
| [[ENERGY CORP OF AMER]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 881.00 Bbl
 
| style="text-align: right;" | 881.00 Bbl
Line 454: Line 458:
 
|  
 
|  
 
|-
 
|-
| 2017-M01
+
| 2016
 +
| [[ENERGY CORP OF AMER]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 130.00 Bbl
+
| style="text-align: right;" | 108.00 Bbl
 +
| CENT WASTE TRT FAC NPDES DISCHARGE
 +
| WVR00521948
 +
|-
 +
| 2016
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 94.00 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW010
 
| WMGR123SW010
 
|-
 
|-
| 2017-M02
+
| 2017
 +
| [[ENERGY CORP OF AMER]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 130.00 Bbl
+
| style="text-align: right;" | 1,180.00 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
| 2017-M03
+
| 2017
 +
| [[ENERGY CORP OF AMER]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 220.00 Bbl
+
| style="text-align: right;" | 105.00 Bbl
| REUSE (AT WELL PAD)
+
| CENT WASTE TRT FAC NPDES DISCHARGE
|  
+
| WVR00521948
 
|-
 
|-
| 2017-M04
+
| 2017
| Produced Fluid (in Barrels) RWC 802
+
| [[ENERGY CORP OF AMER]]
| style="text-align: right;" | 130.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 110.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|
 
|-
 
| 2017-M06
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| style="text-align: right;" | 100.00 Bbl
Line 496: Line 493:
 
| 2D0859721
 
| 2D0859721
 
|-
 
|-
| 2017-M06
+
| 2017
 +
| [[ENERGY CORP OF AMER]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 110.00 Bbl
+
| style="text-align: right;" | 210.00 Bbl
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 130.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 110.00 Bbl
 
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
| 2017-M09
+
| 2017
| Produced Fluid (in Barrels) RWC 802
+
| [[ENERGY CORP OF AMER]]
| style="text-align: right;" | 110.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M10
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 130.00 Bbl
 
| style="text-align: right;" | 130.00 Bbl
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 110.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 105.00 Bbl
 
| CENT WASTE TRT FAC NPDES DISCHARGE
 
| WVR00521948
 
|-
 
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 111.00 Bbl
 
| CENT WASTE TRT FAC NPDES DISCHARGE
 
| WVR00521948
 
|-
 
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 110.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 65.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 220.00 Bbl
 
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW010
 
| WMGR123SW010
 
|-
 
|-
| 2018-M04
+
| 2018
 +
| [[GREYLOCK PROD LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 110.00 Bbl
+
| style="text-align: right;" | 817.00 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
| 2018-M05
+
| 2018
 +
| [[GREYLOCK PROD LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 110.00 Bbl
+
| style="text-align: right;" | 102.48 Bbl
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 110.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
| WMGR123SW010
+
| WMGR123SW019
 
|-
 
|-
| 2018-M07
+
| 2018
| Produced Fluid (in Barrels) RWC 802
+
| [[GREYLOCK PROD LLC]]
| style="text-align: right;" | 92.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 110.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW010
 
|-
 
| 2018-M10
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| style="text-align: right;" | 100.00 Bbl
Line 610: Line 528:
 
| 34-105-23619
 
| 34-105-23619
 
|-
 
|-
| 2018-M11
+
| 2018
 +
| [[GREYLOCK PROD LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 15.00 Bbl
+
| style="text-align: right;" | 375.00 Bbl
| INJECTION DISPOSAL WELL
+
| RESIDUAL WASTE PROCESSING FACILITY
| 34-155-24079
+
| WMGR123SW010
 
|-
 
|-
| 2018-M11
+
| 2018
| Produced Fluid (in Barrels) RWC 802
+
| [[GREYLOCK PROD LLC]]
| style="text-align: right;" | 110.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M12
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 100.00 Bbl
+
| style="text-align: right;" | 115.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-24079
 
| 34-155-24079
 
|-
 
|-
| 2018-M12
+
| 2018
 +
| [[ENERGY CORP OF AMER]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 102.48 Bbl
+
| style="text-align: right;" | 111.00 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| CENT WASTE TRT FAC NPDES DISCHARGE
| WMGR123SW019
+
| WVR00521948
 
|-
 
|-
| 2019-M01
+
| 2019
| Produced Fluid (in Barrels) RWC 802
+
| [[GREYLOCK PROD LLC]]
| style="text-align: right;" | 119.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2019-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 101.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2019-M03
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 91.00 Bbl
+
| style="text-align: right;" | 311.00 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  

Revision as of 13:51, 19 August 2019

Well Details

Well ID: 37-059-26315
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Jefferson Township
Operator Name: GREYLOCK PROD LLC
Well Pad ID: 145746
Farm/Lease Name: BROADWATER 3MH
License Status: Active
Spud Date: 2014-03-12
Permit Date: 2013-12-06
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 39.908050
Longitude: -80.055431

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-11-14 2014-12-01 8035 18,334,600.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Scale Hib A Universal Well Services Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00564 9301.88
EC6116A Universal Well Services Biocide Polyethylene Glycol 25322-68-3 60 0.01126 18582.6
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00563 9291.28
Dibromoacetonitrile 3252-43-5 5 0.00094 1548.55
Proppant-40/70 Universal Well Services Proppant crystalline silica quartz 14808-60-7 100 4.10833 6,778,240.0
Proppant-100 Mesh Universal Well Services Proppant crystalline silica quartz 14808-60-7 100 1.7299 2,854,120.0
7.5 % Hydrochloric Acid (UWS) Universal Well Services Acid Hydrochloric Acid 7647-01-0 7.5 0.0178 29367.1
Sand, Silica Sand (40/70) UWS Universal Well Services Proppant Hydrotreated light paraffinic distillate 6472-55-8 100 1.09151 1,800,860.0
Silica 14808-60-7 99.9 1.09042 1,799,060.0
15% Hydrochloric Acid (UWS) Universal Well Services Acid Hydrochloric Acid 7647-01-0 15 0.02602 42923.3
Water ECA Base Fluid Water N/A 100 92.5689 152,727,000.0
LEB 10X Universal Well Services Breaker Ethylene Glycol 107-21-1 60 0.00023 384.146
Unihib G Universal Well Services Corrosion Inhibitor for Acid Short chained glycol ether N/A 25 0.00009000 141.768
2-Ethyl Hexanol 104-76-7 75 0.00026 425.305
Unislick ST-50 Universal Well Services Friction Reducer Hydrotreated Light Distillate 64742-47-8 30 0.01549 25559.6
WGA-3, CMHPG Universal Well Services Dry Gellant Guar Gum 9000-30-0 100 0.00061 1000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 ENERGY CORP OF AMER 110,476.00 19 0.00 0 0.00 0
2015 ENERGY CORP OF AMER 1,680,471.00 352 0.00 0 0.00 0
2016 ENERGY CORP OF AMER 1,007,272.00 364 0.00 0 0.00 0
2017 ENERGY CORP OF AMER 703,106.00 365 0.00 0 0.00 0
2018 GREYLOCK PROD LLC 517,248.00 334 0.00 0 0.00 0
2019 GREYLOCK PROD LLC 121,634.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 ENERGY CORP OF AMER Drill Cuttings (in Tons) 356.06 Tons LANDFILL 100277
2014 ENERGY CORP OF AMER Drill Cuttings (in Tons) 502.90 Tons LANDFILL 100419
2014 ENERGY CORP OF AMER General O&G waste not covered by other waste types 8.15 Tons LANDFILL 100419
2014 ENERGY CORP OF AMER Fracturing Fluid Waste (in Tons) 8.73 Tons LANDFILL 100277
2014 ENERGY CORP OF AMER Drilling Fluid Waste (in Barrels) 13,245.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ENERGY CORP OF AMER Fracturing Fluid Waste (in Tons) 2.27 Tons LANDFILL 100419
2015 ENERGY CORP OF AMER Produced Fluid (in Barrels) 237.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2015 ENERGY CORP OF AMER Drill Cuttings (in Tons) 222.78 Tons LANDFILL 100419
2015 ENERGY CORP OF AMER Fracturing Fluid Waste (in Tons) 22.16 Tons LANDFILL 100172
2015 ENERGY CORP OF AMER Produced Fluid (in Barrels) 810.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW010
2015 ENERGY CORP OF AMER General O&G waste not covered by other waste types 6.41 Tons LANDFILL 100419
2015 ENERGY CORP OF AMER Fracturing Fluid Waste (in Tons) 0.27 Tons LANDFILL 100594
2015 ENERGY CORP OF AMER Fracturing Fluid Waste (in Tons) 43.66 Tons LANDFILL 100277
2015 ENERGY CORP OF AMER Produced Fluid (in Barrels) 11,742.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ENERGY CORP OF AMER Fracturing Fluid Waste (in Tons) 9.76 Tons LANDFILL 100280
2015 ENERGY CORP OF AMER Fracing Fluid Waste (in Barrels) 29,068.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ENERGY CORP OF AMER Produced Fluid (in Barrels) 200.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 ENERGY CORP OF AMER Produced Fluid (in Barrels) 411.00 Bbl INJECTION DISPOSAL WELL 2D0859721
2016 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 265.00 Bbl INJECTION DISPOSAL WELL 2D0859721
2016 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 2,050.00 Bbl INJECTION DISPOSAL WELL 34-167-29543
2016 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 881.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 108.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE WVR00521948
2016 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 94.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2017 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 1,180.00 Bbl REUSE (AT WELL PAD)
2017 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 105.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE WVR00521948
2017 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 100.00 Bbl INJECTION DISPOSAL WELL 2D0859721
2017 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 210.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2018 GREYLOCK PROD LLC Produced Fluid (in Barrels) RWC 802 817.00 Bbl REUSE (AT WELL PAD)
2018 GREYLOCK PROD LLC Produced Fluid (in Barrels) RWC 802 102.48 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 GREYLOCK PROD LLC Produced Fluid (in Barrels) RWC 802 100.00 Bbl INJECTION DISPOSAL WELL 34-105-23619
2018 GREYLOCK PROD LLC Produced Fluid (in Barrels) RWC 802 375.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2018 GREYLOCK PROD LLC Produced Fluid (in Barrels) RWC 802 115.00 Bbl INJECTION DISPOSAL WELL 34-155-24079
2018 ENERGY CORP OF AMER Produced Fluid (in Barrels) RWC 802 111.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE WVR00521948
2019 GREYLOCK PROD LLC Produced Fluid (in Barrels) RWC 802 311.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2254714 Primary Facility 2014-03-17 Drilling/Alteration No Violations Noted 20" Conductor casing set to 80'
2274197 Primary Facility 2014-05-27 Drilling/Alteration No Violations Noted Drill to 875'; Set 13 3/8"@ 842'; baskets @ 760'; 770'; Cemented well but lost circulation; cemented down annulus; returns to surface; drill to 2300'; set 9 5/8"@ 2276'; cemented well to surface; waitingon cement;
2300261 Primary Facility 2014-08-25 Drilling/Alteration No Violations Noted TOP HOLE SETS DRILLED. HWD RIG 10 ON SITE DRILLING LATERALS.
2304832 Primary Facility 2014-09-09 Drilling/Alteration No Violations Noted HWD RIG 10 DRILLING FOR ECA. RIG SKIDDED TO WELL PREPARING TO DRILL. BOP TESTS COMPLETE.
2406040 Primary Facility 2015-08-12 Complaint Inspection No Violations Noted On 8/12/15, I inspected the Broadwater site in response to a complaint and made the following observations:
2439791 Primary Facility 2015-11-04 Incident- Response to Accident or Event No Violations Noted On 11/4/15, I performed an incident inspection for the Broadwater Well Site at the request of the operator with regards to landowner damaged BMP’s and site NOT preparation; the following was observed:
2732906 Primary Facility 2018-03-01 Complaint Inspection No Violations Noted A complaint inspection was conducted in response to a water supply complaint near the site. The Act 9 sign was in place and required documents were present at the site. The production equipment appeared to be in good condition. There were no signs of leaks or spills observed. The site was well vegetated and there were no signs of erosion observed.

PCSM features shown on the plans were not present at the site. In 2015 the Operator provided the Department with evidence of third party impacts and efforts taken to prevent them. The Department documented third party impacts in site inspection #2439787. An NOT submittal by Greylock would be reviewed noting the absence of PCSM as a result of third party impacts.

For data sources see[7]