37-063-23768

Well Details

Well ID: 37-063-23768
Loading map...
Operator Name: ENERGY CORP OF AMER
First Permit Date: 1977-05-06
Last Permit Date: 1977-05-06
Spud Date: 1978-06-19
Unconventional: No
Horizontal: No
Violations: 2
Latitude: 40.864856
Longitude: -78.849147

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2010-0 0.0 0.0 0.0 0.0 0.0 0.0
2009-0 0.0 0.0 0.0 0.0 0.0 0.0
2008-0 0.0 0.0 0.0 0.0 0.0 0.0
2007-0 0.0 0.0 0.0 0.0 0.0 0.0
2006-0 0.0 0.0 0.0 0.0 0.0 0.0
2005-0 272.0 243.0 0.0 0.0 0.0 0.0
2004-0 443.0 335.0 0.0 0.0 0.0 0.0
2003-0 810.0 282.0 0.0 0.0 0.0 0.0
2002-0 1958.0 330.0 0.0 0.0 0.0 0.0
2001-0 1948.0 365.0 0.0 0.0 0.0 0.0
2000-0 2755.0 336.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2000-0 BRINE 120.0 Bbl MUNICIPAL SEWAGE TREATMENT PLANT CLEARFLD STP
2000-0 BRINE 120.0 Bbl INJECTION DISPOSAL WELL DANDO DW
2001-0 BRINE 74.0 Bbl BRINE OR INDUSTRIAL WASTE TREATMENT PLT CLEARFLD STP
2002-0 BRINE 80.0 Bbl BRINE OR INDUSTRIAL WASTE TREATMENT PLT Clearfield Municipal
2003-0 BRINE 80.0 Bbl BRINE OR INDUSTRIAL WASTE TREATMENT PLT CLEARFIELD MUNI STP

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
581771 1999-08-17 No Violations Noted OPERATING; ID/E&S/TANK/OK
923918 2000-03-15 No Violations Noted 8 5/8 x 4 1/2 annular flow occurring; sample taken for analysis
1826734 2009-09-01 Violation(s) Noted 571049
1826734 2009-09-01 Violation(s) Noted 571049
1827387 2009-08-26 Pending Inspection conducted with oil &gas inspector Rick Hoover.

Well is equipped for production, but currently shut in. Well continues to flow artesian from 8 5/8¿ surface casing hanger creating a pool of fluids around the well equipment and across a portion of the site. Further investigation to be done by Mr. Hoover (abandoned well, plugging required, etc.).

1827389 2009-08-25 Pending Well tag in place. Well is equipped for production (shut in).

Access road was stabilized with vegetation (basically grown shut). Site was stabilized with vegetation. Well and associated production equipment surrounded by a small pond filled with what appeared to be AMD. Water sample was taken. Fiberglass tank was no longer plumbed into well. Tank appeared sound, although bottom 1-3 inches of tank was submerged in water. No holes could be seen in visible portion of tank. A large amount of fluid was flowing artisian from 8 5/8" surface casing hanger, contributing to the pooled water surrounding the well. This concern, along with the possibility of the well being abandoned if not produced in the preceding 12 months was discussed with oil & gas inspector Rick Hoover. Enforcement action pending on further investigation.


1829352 2009-09-08 Outstanding Violations - No Viols Req'd on-site meeting with operator to discuss proposed plugging proceedures - NOV had been issued for abandoned well
1830821 2009-09-21 Violation(s) Noted Water sample was taken on 8/25/09 from artesian flow of fluids from 8 5/8" surface casing hanger./ Administrative review of sample results revealed the following:/ 1) Discharge of industrial waste to the ground./ Sample results report the discharged fluids on the well site contained high levels of iron (26.0 mg/L), manganese (2.855 mg/L), and aluminum (0.977 mg/L)./ A ph of 5.3 was also reported./ These fluids were pooled around the well head and production equipment, and continued throughout a large portion of the site./ Based on the amount of fluids present, and the conditions on site, it appears as though the artesian flow has been occurring for a long period of time./ Since the initial inspection on 8/25/09, myself and oil & gas inspector Rick Hoover have consulted with operator representatives who indicated this well will be plugged./ Please submit any interim controls/plans to alleviate the above concern and a timeframe of plugging./ 572332
1830821 2009-09-21 Violation(s) Noted Water sample was taken on 8/25/09 from artesian flow of fluids from 8 5/8" surface casing hanger./ Administrative review of sample results revealed the following:/ 1) Discharge of industrial waste to the ground./ Sample results report the discharged fluids on the well site contained high levels of iron (26.0 mg/L), manganese (2.855 mg/L), and aluminum (0.977 mg/L)./ A ph of 5.3 was also reported./ These fluids were pooled around the well head and production equipment, and continued throughout a large portion of the site./ Based on the amount of fluids present, and the conditions on site, it appears as though the artesian flow has been occurring for a long period of time./ Since the initial inspection on 8/25/09, myself and oil & gas inspector Rick Hoover have consulted with operator representatives who indicated this well will be plugged./ Please submit any interim controls/plans to alleviate the above concern and a timeframe of plugging./ 572332
1831798 2009-09-22 Outstanding Violations - No Viols Req'd NOV previously issued for abandoned well/WQS to issue NOV for fluids discharge/operator working towards plugging well
1835382 2009-10-06 No Violations Noted Inspection conducted with Oil & Gas Inspector Rick Hoover.

Well being plugged at time of inspection. Rig and operator representatives on site. Access road stable, with no signs of accelerated erosion. Limestone lined ditch was installed to drain some standing water from the site to enable rig access. Hay bales and silt fence was installed to allow solids/sediment to settle out. No violations found.

1835938 2009-10-05 Outstanding Violations - No Viols Req'd well in process of being plugged/E&S ok/tag ok
1835940 2009-10-06 Outstanding Violations - No Viols Req'd plugging in process/E&S ok/tag ok
1835944 2009-10-07 Outstanding Violations - No Viols Req'd plugging continuing/pit ok/E&S ok/tag ok
1835948 2009-10-08 No Violations Noted plugging continuing - artesian flow partially stopped/E&S ok/tag ok/pit ok
1835981 2009-10-13 No Violations Noted CEI - compliance/discharge from well sealed - well plugged/E&S ok/monument installed
1837745 2009-10-16 No Violations Noted plugging complete - water flow stopped/monument&tag installed/E&S ok
1842346 2009-11-05 No Violations Noted Well plugged. Permit number affixed to 2"pipe.

Inspection conducted with Rick Hoover of DEP. Site has been backfilled and seeded/mulched. Access road stable, with no signs of accelerated erosion.

  • Production fluids tank and pipe left on site. Once site becomes stable enough for access this equipment should be removed. Notified
   operator representative Mark Fry of this concern.  Please contact this office upon completion.

No violations found.

1871240 2010-03-10 No Violations Noted plugged - no gas/fluids @ surface/E&S ok/monument&tag installed