37-111-20083

Well Details

Well ID: 37-111-20083
Loading map...
Operator Name: BG PROD LLC
First Permit Date: 1979-05-25
Last Permit Date: 1979-05-25
Spud Date: 1979-09-08
Unconventional: No
Horizontal: No
Violations: None
Latitude: 40.039218
Longitude: -79.05783

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2011-0 9275.0 365.0 0.0 0.0 0.0 0.0
2010-0 3009.0 365.0 0.0 0.0 0.0 0.0
2009-0 3827.0 365.0 0.0 0.0 0.0 0.0
2008-0 8430.0 365.0 0.0 0.0 0.0 0.0
2007-0 10090.0 365.0 0.0 0.0 0.0 0.0
2006-0 6802.0 365.0 0.0 0.0 27.0 365.0
2005-0 8525.0 365.0 0.0 0.0 0.0 0.0
2004-0 14004.0 365.0 0.0 0.0 0.0 0.0
2003-0 14235.0 365.0 0.0 0.0 0.0 0.0
2002-0 17612.0 334.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2005-0 BRINE 28.0 Bbl OTHER NOT LISTED
2009-0 PRODUCED FLUID 69.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 5601202-T2 BRANT DISPOSAL BUFFALO NY
2011-0 PRODUCED FLUID 66.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273 PA BRINE TRT INC - JOSEPHINE PLT, INDIANA COUNTY JOSEPHINE PA

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
683600 1991-10-03 Violation(s) Noted NO ID;E&S OK;TANK 95130
683623 1991-11-25 No Violations Noted TAG ON; E&S OK
684115 1992-02-05 No Violations Noted E&S OK; TANK
1802940 2009-06-04 No Violations Noted Based on file records, well was completed on 10/7/79 to a depth of 9,125 ft. from grade and maintains an active permit status. During inspection, the proper well tag was present. The well was completed with 13", 7" flange well assembly retrofitted with 3 gate valves and reduced to 2 inch production lines. Line pressure reading at 275 psi. Pressure readings on the dual pen data logger showing 250 psi/50 psi. Site also contained brine release float, seperator, heating unit and 100 bbl brine tank on concrete pad. The status of the valves were located in the on position. No signs of gas leakage occuring around the well. At the time of the inspection, no IW discharge or E&S issues. Well head and compressior unit which was injecting a surfacant into the well head located under a car port canvas.