37-125-23334

Well Details

Well ID: 37-125-23334
Loading map...
County: Washington
Municipality: Robinson Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 149200
Farm/Lease Name: ROBINHILL 19H
First Permit Date: 2008-10-09
Last Permit Date: 2008-10-09
Spud Date: 2008-11-10
Unconventional: Yes
Horizontal: Yes
Well Status: ACTIVE
Violations: 0
Latitude: 40.452937
Longitude: -80.343859

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2008-0 0.0 0.0 0.0 0.0 0.0 0.0
2010-3 0.0 0.0 0.0 0.0 0.0 0.0
2009-0 0.0 0.0 0.0 0.0 0.0 0.0
2010-2 245299.0 184.0 0.0 0.0 2352.0 184.0
2010-2 245299.0 184.0 0.0 0.0 2352.0 184.0
2011-1 194275.0 181.0 772.0 181.0 0.0 0.0
2011-1 0.0 0.0 0.0 0.0 0.0 0.0
2011-2 0.0 0.0 0.0 0.0 0.0 0.0
2012-1 26150.0 182.0 74.54 182.0 0.0 0.0
2012-2 15676.0 184.0 224.07 184.0 0.0 0.0
2013-1 0.0 0.0 1.03 90.0 0.0 0.0
2013-2 0.0 0.0 0.0 0.0 0.0 0.0
2014-1 0.0 0.0 0.0 0.0 0.0 0.0
2014-2 0.0 0.0 978.0 1.0 0.0 0.0
2015-02 0.0 0.0 0.0 0.0 0.0 0.0
2015-01 0.0 0.0 0.0 0.0 0.0 0.0
2015-03 0.0 0.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2010-3 FRACING FLUID WASTE 19.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAR000519462 ADVANCED WASTE SERVICES OF PA LLC NEW CASTLE PA
2010-3 FRACING FLUID WASTE 2.0 Bbl IDENTIFY METHOD IN COMMENTS NOT LISTED (PROVIDE NAME & ADDRESS IN COMMENTS) PA
2010-3 PRODUCED FLUID 7.0 Bbl IDENTIFY METHOD IN COMMENTS NOT LISTED (PROVIDE NAME & ADDRESS IN COMMENTS) PA
2010-2 PRODUCED FLUID 800.0 Bbl STORAGE PENDING DISPOSAL OR REUSE 34-121-2-3995 HUNTERS SWIW #5 RENO OH
2010-2 PRODUCED FLUID 7.0 Bbl IDENTIFY METHOD IN COMMENTS 34-167-29359 WEST VIRGINIA OIL GATHERING
2011-1 PRODUCED FLUID 673.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE HUNTER DISPOSAL DEXTER CITY OH
2011-1 PRODUCED FLUID 5.0 Bbl IDENTIFY METHOD IN COMMENTS 34-167-29359 WEST VIRGINIA OIL GATHERING
2011-2 PRODUCED FLUID 384.0 Bbl INJECTION DISPOSAL WELL 34-121-2-3995 HUNTERS SWIW #5 RENO OH
2012-1 PRODUCED FLUID 57.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) HUNTER DISPOSAL DEXTER CITY OH
2012-2 FLOWBACK FRACTURING SAND 2.7 Tons LANDFILL SWF 1025 WASTE MANAGEMENT, INC - NORTHWESTERN LANDFILL PARKERSBURG WV
2012-2 FRACING FLUID WASTE 185.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2012-2 PRODUCED FLUID 583.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH
2013-1 PRODUCED FLUID 24.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH
2013-2 PRODUCED FLUID 1.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH
2014-1 PRODUCED FLUID 3.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH
2014-2 PRODUCED FLUID 3.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
1836956 2009-10-21 No Violations Noted The operator submitted a request for a six month site restoration extension on 10/9/09 due to pipeline and compressor station scheduling difficulties. The well reached total depth on 12/14/08 and the ID sign and E&S plan was on site. All E&S controls were installed properly and need to be maintained and inspected after every significant rainfall event. The following extension has been approved, and the deadline for the site restoration is 4/21/09. The Department requests that the fill slop be inspected on a regular basis to hinder any accelerated erosion
1910624 2010-07-28 No Violations Noted On July 28th, 2010 I conducted a routine inspection of the above site. Drilling was completed and the well was in production. The access road was in good condition. A site ID sign and E&S plan were on posted site. A well tag was present. Drilling pits had been closed. The site was graded, seeded and mulched and growth was coming in well. The well head was enclosed by a security fence. The tanks were enclosed with a lined and steel walled secondary containment structure. The E&S controls appeared to be functioning properly and should continue to be inspected routinley and after every significant rainfall event.
1944796 2010-11-16 No Violations Noted
1959549 2011-03-10 No Violations Noted On March 10th, 2011 I conducted a routine inspection of the above site. Drilling was completed and the well was in production. The access road was in good condition. A site ID sign and E&S plan were on posted site. A well tag was present. The site was restored and had good growth. The well head was enclosed by a security fence. The tanks were enclosed with a lined and steel walled secondary containment structure. A small ditch was beginning to erode at the back of the pad due to the recent rains. The operator was notified ant crews were onsite immediately to stake hay bales at the top of the pad and line the ditch with hay to curtail any further erosion.
2353955 2015-03-19 No Violations Noted

For data sources see[3]