37-125-24311

Well Details

Well ID: 37-125-24311
Loading map...
County: Washington
Municipality: Robinson Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 146945
Farm/Lease Name: ROBINHILL UNIT 9H
First Permit Date: 2010-10-19
Last Permit Date: 2010-10-19
Spud Date: 2010-12-07
Unconventional: Yes
Horizontal: Yes
Well Status: ACTIVE
Violations: 0
Latitude: 40.457361
Longitude: -80.357111

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2010-2 0.0 0.0 0.0 0.0 0.0 0.0
2010-2 0.0 0.0 0.0 0.0 0.0 0.0
2011-1 0.0 0.0 0.0 0.0 0.0 0.0
2011-1 0.0 0.0 0.0 0.0 0.0 0.0
2011-2 110147.0 46.0 502.56 46.0 0.0 0.0
2012-1 253547.0 182.0 763.53 182.0 0.0 0.0
2012-2 15156.0 184.0 40.93 184.0 0.0 0.0
2013-1 117633.0 181.0 341.59 181.0 0.0 0.0
2013-2 128753.0 184.0 140.56 184.0 0.0 0.0
2014-1 150074.0 181.0 163.91 181.0 0.0 0.0
2014-2 113971.0 184.0 728.0 184.0 270.76 184.0
2015-02 15270.0 28.0 0.0 0.0 25.14 28.0
2015-01 18103.0 31.0 0.0 0.0 0.0 0.0
2015-03 18732.0 31.0 0.0 0.0 17.2 31.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2011-1 DRILLING FLUID WASTE 3.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAR000519462 ADVANCED WASTE SERVICES OF PA LLC NEW CASTLE PA
2011-1 FRACING FLUID WASTE 2.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAR000519462 ADVANCED WASTE SERVICES OF PA LLC NEW CASTLE PA
2011-1 FRACING FLUID WASTE 75.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE HUNTER DISPOSAL DEXTER CITY OH
2011-1 FRACING FLUID WASTE 910.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2011-1 FRACING FLUID WASTE 350.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2011-1 FRACING FLUID WASTE 475.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472 TUNNELTON LIQUIDS TREATMENT FACILITY SALTSBURG PA
2011-1 FRACING FLUID WASTE 392.0 Bbl IDENTIFY METHOD IN COMMENTS 34-167-29359 WEST VIRGINIA OIL GATHERING
2011-1 PRODUCED FLUID 10.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAR000519462 ADVANCED WASTE SERVICES OF PA LLC NEW CASTLE PA
2011-1 PRODUCED FLUID 865.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508 FLUID RECOVERY SERVICE FRANKLIN FACILITY FRANKLIN PA
2011-1 PRODUCED FLUID 110.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273 FLUID RECOVERY SERVICE JOSEPHINE FACILITY JOSEPHINE PA
2011-1 PRODUCED FLUID 8.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-007-24355 MILLER & CO #3 (SWIW #28) GARRETTSVILLE OH
2011-1 PRODUCED FLUID 960.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2011-1 PRODUCED FLUID 4.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472 TUNNELTON LIQUIDS TREATMENT FACILITY SALTSBURG PA
2011-2 PRODUCED FLUID 3.0 Bbl INJECTION DISPOSAL WELL 34-121-2-3995 HUNTERS SWIW #5 RENO OH
2012-1 PRODUCED FLUID 4.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) HUNTER DISPOSAL DEXTER CITY OH
2012-2 PRODUCED FLUID 697.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH
2013-1 PRODUCED FLUID 1.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH
2013-2 PRODUCED FLUID 1.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH
2014-1 PRODUCED FLUID 1.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH
2014-2 PRODUCED FLUID 808.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
1938169 2010-12-16 No Violations Noted Whipstock 17- TD@3246, Drilling vertical ahead, returns on cement, site and location good, pit good
1944795 2010-01-16 No Violations Noted
1943252 2011-01-06 No Violations Noted On January 6th, 2011 I conducted an inspection of the above site. A seam of coal had been encountered during construction of the pad and drilling pit. I met with Atlas representatives Gary Bowlen, Chad Eisenman, and Nick Staffieri on site. Approximately 300 tons of coal was encountered. Laboratory analysis showed a BTU value of 7,141 and a sulfur content of 0.60%. The coal was stock piled on site on a base of crushed limestone and surrounded by an earthen berm. A coal handling report was provided (attached). The coal will be mixed with 18 tons of limestone when replaced and encapsulated. I instructed the operator to cover the coal stock pile to avoid contact with precipitation and prevent any acidic runoff.
1953099 2011-01-25 No Violations Noted On January 25th, 2011 I conducted a follow up inspection of the above site in response to the coal encounter and inspection on January 6th, 2011. The stock pile is now covered with soil to prevent contact with precipitation. no runoff was observed from the stock pile. The rig was moving on site. Crews were laying out containment plastic under the rig and associated equipment. Drilling has not yet started. The access road was in good condition. A Site ID and E&S Plan were posted. The pits apperaered to be in good condition. No spills, leaks, or accelerated erosion were obseerved at the time of inspection.
1953668 2011-01-27 No Violations Noted Crown 8 - Rigged up , picking up directional tools to begin building curve, site and location good, pit good.
1953671 2011-01-31 No Violations Noted Crown 8 - TD@9131, 51/2 run and cemented back to surface, rigging down, site and location good, pit good.
1958462 2011-02-09 No Violations Noted On February 9th, 2011 I conducted a routine inspection of the above site. No runoff was observed from the coal stock pile. The rig has moved off site. The access road was in good condition. A Site ID and E&S Plan were posted. The pits apperaered to be in good condition. No spills, leaks, or accelerated erosion were observed at the time of inspection.
1958811 2011-02-23 No Violations Noted On February 23rd, 2011 I conducted a routine inspection of the above site. No runoff was observed from the coal stock pile. The rig has moved off site. The access road was being repaired. A Site ID and E&S Plan were posted. The pits were being expanded by raising the berm. Drill cuttings were hauled offsite. Water trucks wee bringing water in to fill the pits. No spills, leaks, or accelerated erosion were observed at the time of inspection.
1972157 2011-04-13 No Violations Noted 4/12/11 ﾿ Called complainant and talked over situation. Made preliminary arrangements to visit week of April 18th.

4/13/11 ﾿ Mr. McDonald called and said that he had ﾿excessive﾿ pressure in his water. I was worried about possible methane in their well and changed my plans to make a quick inspection. I found no explosive gases from the kitchen sink or the outside well.

1972158 2011-04-19 No Violations Noted 4/19/11 ﾿ I sampled the McDonald﾿s well for total coliforms and inorganic compounds. I also took one of the McDonald﾿s cartridges, particulate filters for microscopic analysis. I also took photos of the well location.

The coliform test and the microscopic examination of the filter sediment indicate surface water infiltration into the well. The inorganic analysis showed nothing unusual.

5/5/11 ﾿ I stopped at the McDonalds and gave him a copy of the lab results. We discussed them briefly and I told him I suspected more of a surface water problem compounded by the recent heavy rains.

This complaint is closed May 11, 2011.

1984476 2011-05-27 No Violations Noted On May 27th, 2011 I conducted a routine inspection of the above site. Drilling and frac were complete. Site restoration was underway. The access road was in good condition. A Site ID and E&S Plan were posted. The pits were closed and filled. Drill cuttings were hauled offsite. Efforts were being made to stabilize the fill slope and handle several spring time seeps. No spills, leaks, or accelerated erosion were observed at the time of inspection.
1986459 2011-06-13 No Violations Noted On June 13th, 2011 I met with Chevron representative George Bozek on above site to discuss restoration efforts. Drilling and frac were complete. Site restoration was underway. The access road was in good condition. A Site ID and E&S Plan were posted. The pits were closed and filled. Drill cuttings were hauled offsite. Efforts were being made to stabilize the fill slope and handle several spring time seeps. At this time water is being directed around the site. Final restoration plan to include additional riprap and filter sock to remain in place until permanent vegetation is established. No spills, leaks, or accelerated erosion were observed at the time of inspection.
2082333 2012-07-06 No Violations Noted On July 6, 2012, I stopped at Robinhill #9 to check the condensate control measures Chevron took. The wellï¾’s annulus was vented to a small tank and the pipes had matting underneath them. I found no problems.
2083647 2012-07-12 No Violations Noted On July 12, 2012, I stopped at Robinhill #9 with Brian Rankin & Jared Reichard of Chevron to check the restoration of Robinhill #9. This well site is currently shut down because of a small condensate release. Chevron made repairs and they were able to restrict the condensate release to the wellï¾’s cellar. Brian told me that they would be removing the rock in the cellar and talking it to a landfill.

The site appears to be in good shape and is well vegetated.

2085178 2012-07-20 No Violations Noted
2163799 2013-04-16 No Violations Noted
2212399 2013-10-02 No Violations Noted
2353951 2015-03-19 No Violations Noted

For data sources see[3]

References