X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-24334

Well Details

Well ID: 37-125-24334
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: West Bethlehem Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148469
Farm/Lease Name: HAMBLETON UNIT 5H
License Status: Active
Spud Date: 01/21/2011
Permit Date: 12/3/2010
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.055592
Longitude: -80.134692

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 92,186.00 61 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 1,352,979.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 745,336.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 508,472.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 401,054.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 321,533.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 253,200.00 334 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 62,161.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2011-1 Drilling Fluid Waste (in Barrels) 100.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE
2011-1 Drilling Fluid Waste (in Barrels) 2,130.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2011-1 Drilling Fluid Waste (in Barrels) 4,250.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011-1 Drilling Fluid Waste (in Barrels) 545.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2011-1 Drilling Fluid Waste (in Barrels) 330.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011-2 Drilling Fluid Waste (in Barrels) 497.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012-1 Fracing Fluid Waste (in Barrels) 7,428.20 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Fracing Fluid Waste (in Barrels) 218.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012-2 Fracing Fluid Waste (in Barrels) 9,811.60 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Fracturing Fluid Waste (in Tons) 69.45 Tons LANDFILL 100172
2012-2 Produced Fluid (in Barrels) 343.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Fracturing Fluid Waste (in Tons) 59.09 Tons LANDFILL 100172
2013-1 Produced Fluid (in Barrels) 2,765.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Produced Fluid (in Barrels) 1,450.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 86.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014-1 Produced Fluid (in Barrels) 1,483.60 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 794.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 60.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2015-1 Produced Fluid (in Barrels) 644.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Fracing Fluid Waste (in Barrels) 24.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015-2 Fracturing Fluid Waste (in Tons) 0.47 Tons LANDFILL 100172
2015-2 Produced Fluid (in Barrels) 581.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 24.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-1 Produced Fluid (in Barrels) RWC 802 663.12 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Fracturing Fluid Waste (in Barrels) RWC 805 1.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-2 Produced Fluid (in Barrels) RWC 802 285.21 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-2 Produced Fluid (in Barrels) RWC 802 93.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Produced Fluid (in Barrels) RWC 802 100.89 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-02 Produced Fluid (in Barrels) RWC 802 75.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-03 Produced Fluid (in Barrels) RWC 802 48.11 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-05 Produced Fluid (in Barrels) RWC 802 1,008.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017-05 Produced Fluid (in Barrels) RWC 802 2,016.00 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 92.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017-07 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 42.00 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 24.00 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-11 Produced Fluid (in Barrels) RWC 802 65.87 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-12 Produced Fluid (in Barrels) RWC 802 43.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-01 Produced Fluid (in Barrels) RWC 802 134.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018-02 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE (AT WELL PAD)
2018-03 Produced Fluid (in Barrels) RWC 802 66.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-03 Produced Fluid (in Barrels) RWC 802 65.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-05 Produced Fluid (in Barrels) RWC 802 22.00 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 152.00 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 23.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-08 Produced Fluid (in Barrels) RWC 802 64.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-09 Produced Fluid (in Barrels) RWC 802 41.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-11 Produced Fluid (in Barrels) RWC 802 69.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-12 Produced Fluid (in Barrels) RWC 802 62.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-01 Produced Fluid (in Barrels) RWC 802 120.00 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 68.00 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1953719 Primary Facility 01/23/2011 Drilling/Alteration No Violations Noted Rocky Mountian Drilling - spud conductor , site still under construction , E&S in place
1953721 Primary Facility 02/23/2011 Drilling/Alteration No Violations Noted Nomak 230 - TD@ 830 drilling ahead- returns on cement, site and location good, pit good
1987104 Primary Facility 07/07/2011 Drilling/Alteration No Violations Noted Crown 5 - TD@ 5918, Fishing for motor and bit, site and location good, pit good,
1989634 Primary Facility 07/14/2011 Drilling/Alteration No Violations Noted Crown 5 - TD@ 5536, Rig down for repairs, site and location good, pit good,
1989635 Primary Facility 07/20/2011 Drilling/Alteration No Violations Noted Crown 5 - TD@ 6145, Tripping back in hole to retrieve BHA, site and location good, pit good.
1999338 Primary Facility 05/20/2011 Complaint Inspection No Violations Noted
2003239 Primary Facility 09/14/2011 Drilling/Alteration No Violations Noted Patterson 334 - TD@ 11652, drilling completed, running 5 1/2 Production, site, location,pit good
2065442 Primary Facility 04/06/2012 Incident- Response to Accident or Event Violation(s) Noted
2065944 Primary Facility 04/09/2012 Incident- Response to Accident or Event No Violations Noted viols for this inspection linked to 1H inspection # 2065932
2069673 Primary Facility 05/02/2012 Compliance Evaluation No Violations Noted
2080046 Primary Facility 06/26/2012 Drilling/Alteration No Violations Noted
2080828 Primary Facility 06/19/2012 Routine/Complete Inspection No Violations Noted On June 19, 2012, I stopped at the Chevron’s Hambelton site for a routine inspection. The site has five stimulated wells but is not yet in production.
2080861 Primary Facility 07/03/2012 Follow-up Inspection No Violations Noted viols from the 4/9/12 release (eFACTS #2065934) have been corrected.
2129957 Primary Facility 10/03/2012 Complaint Inspection No Violations Noted I did a preliminary investigation and gathered background and historical information but was unable to sample because Mr. Hutchinson was not available to work the plumbing. I made preliminary plans to sample and left.
2130011 Primary Facility 12/06/2012 Complaint Inspection No Violations Noted Scheduling conflicts made sampling difficult. On December 6, 2012 I again, stopped at the Hutchison residence and made arrangements to sample the water.
2130062 Primary Facility 12/12/2012 Complaint Inspection No Violations Noted Scheduling conflicts made sampling difficult. On December 6, 2012 I again, stopped at the Hutchison residence and made arrangements to sample the water.
2130098 Primary Facility 01/14/2013 Administrative/File Review No Violations Noted I received the various lab results and checked them against Moody's (Chevron's enviromental contractor) report. It does nto appear that the Hambleton gas wells impacted theHutchison's water supply. See attached report.
2219393 Primary Facility 10/24/2013 Complaint Inspection No Violations Noted On October 24, 2013, I met with representatives from Moody and Associates to sample the Ed Nowak home water well and re-sample the Nowak industries/Black burn home water well (this well serves both the shop and the Blackburn home).
2295977 Primary Facility 07/24/2014 Routine/Complete Inspection No Violations Noted Inspection of well - tag should be upgraded - difficult to find and illegible. Site appears to be restored and is stabilized. All temporary E&S controls have been removed.
2296007 Primary Facility 08/12/2014 Follow-up Inspection No Violations Noted Well tag placed in a conspicuous area on the well head and is legible. Site is restored and stable.
2417339 Primary Facility 10/14/2015 Routine/Complete Inspection No Violations Noted On 10/14/15, I performed a routine complete inspection on the Hambleton Unit and made the following observations:

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2065442 639137 04/06/2012 05/02/2012 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
639137 283685 NOV - Notice of Violation Comply/Closed 05/02/2012
639137 287522 CACP - Consent Assessment of Civil Penalty Comply/Closed 08/17/2012 08/17/2012 $3,750.00 $3,750.00

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 04/12/2012 04/12/2012 6000.00 4,421,701.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.29
CMHPG Ashland Water Viscosifier Carboxymethylhydroxyporoyl guar blend 100.00 0.00311000
Iron Control A Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00684000
Clean Volume (gals) Carrier/Base Fluid 92.18 100.00
Unislik ST 50 CESI Chemical Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
GBL Clearwater International Gel Breaker Ethylene glycol 107-21-1 60.00 0.00005000
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
Biocide EC 6116A Nalco Biocide Dibromoacetonitrile 3252-43-5 5.00 0.00115000
Polyethylene glycol 25322-68-3 60.00 0.01
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00692000
Scale Inhibitor A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00685000
Proppant (lbs) Proppant 7.82 8.46

For data sources see[7]

References