{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.039603,"lon":-80.067308,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: West Bethlehem Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 144580 | |
Farm/Lease Name: SARGENT UNIT 8H | |
License Status: Active | |
Spud Date: 2013-06-18 | |
Permit Date: 2013-01-16 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.039603 | |
Longitude: -80.067308 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-02-24 | 2015-03-31 | 7829 | 6,439,360.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | B466 | Schlumberger | Friction Reducer | Distillates (petroleum), hydrotreated light | 64742-47-8 | 30 | 0.00291958 | 0 |
Ammonium Acetate | 631-61-8 | 6 | 0.00058392 | 0 | ||||
Alcohol Ethoxylates | Proprietary | 5 | 0.0004866 | 0 | ||||
15% Acid | Schlumberger | Perf Cleanup | Hydrocloric Acid | 7647-01-0 | 15 | 0.00945049 | 0 | |
A264 | Schlumberger | Corrosion Inhibitor | Aliphatic acids | Proprietary | 30 | 0.00003169 | 0 | |
Prop-2-yn-1-ol | 107-19-7 | 10 | 0.00001056 | 0 | ||||
Methanol | 67-56-1 | 40 | 0.00004225 | 0 | ||||
Aliphatic alcohols, ethoxylayed #1 | Proprietary | 30 | 0.00003169 | 0 | ||||
Base Fluid | Chevron | Carrier/Base Fluid | Water (Including Mix Water Supplied by Client) | 7732-18-5 | 100 | 89.2994 | 0 | |
EC6673W | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30 | 0.00078489 | 0 | |
EC6486A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.0008457 | 0 | |
J580 | Schlumberger | Gelling Agent, Water | Carbohydrate Polymer | Proprietary | 100 | 0.0411913 | 0 | |
Proppant | Schlumberger | Proppant | Crystalline Silica | 14808-60-7 | 100 | 10.5202 | 0 | |
J134 | Schlumberger | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 100 | 0.00196885 | 0 | |
L058 | Schlumberger | Iron Stabilizer | Sodium erythorbate | 6381-77-7 | 100 | 0.00056794 | 0 | |
EC6116A | Nalco | Biocide | Polyethylene Glycol | 25322-68-3 | 60 | 0.00142552 | 0 | |
Dibromoacetonitrile | 3252-43-5 | 5 | 0.00011879 | 0 | ||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00071276 | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 985,471.00 | 162 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 1,446,901.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 863,304.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 631,989.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 130,939.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2013-S02 | Drill Cuttings (in Tons) | 200.70 Tons | LANDFILL | 100172 |
2013-S02 | Drilling Fluid Waste (in Barrels) | 60.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2013-S02 | Drilling Fluid Waste (in Barrels) | 200.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Drill Cuttings (in Tons) | 263.54 Tons | LANDFILL | 100172 |
2014-S01 | Drill Cuttings (in Tons) | 279.53 Tons | LANDFILL | 100592 |
2014-S01 | Drill Cuttings (in Tons) | 185.57 Tons | LANDFILL | 100663 |
2014-S01 | Drilling Fluid Waste (in Barrels) | 181.11 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S01 | Drilling Fluid Waste (in Barrels) | 27.22 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Fracing Fluid Waste (in Barrels) | 11.11 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S02 | Drill Cuttings (in Tons) | 101.90 Tons | LANDFILL | 100172 |
2014-S02 | Drill Cuttings (in Tons) | 5.20 Tons | LANDFILL | 100663 |
2015-S01 | Fracing Fluid Waste (in Barrels) | 1,564.56 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S01 | Fracturing Fluid Waste (in Tons) | 31.33 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2015-S01 | Produced Fluid (in Barrels) | 74.44 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Fracing Fluid Waste (in Barrels) | 494.44 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S02 | Fracing Fluid Waste (in Barrels) | 0.03 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2015-S02 | Fracing Fluid Waste (in Barrels) | 5,158.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Fracturing Fluid Waste (in Tons) | 0.60 Tons | STORAGE PENDING DISPOSAL OR REUSE | MID0209062814 |
2015-S02 | Produced Fluid (in Barrels) | 5,549.44 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 28.67 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 4,559.83 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 2,090.64 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 404.58 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 0.06 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 93.75 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 55.63 Bbl | REUSE (AT WELL PAD) | |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 25.78 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 5.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 15.91 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 148.21 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M01 | Other Oil & Gas Wastes (in Tons) RWC 899 | 0.03 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 41.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 163.88 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 54.63 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 28.38 Bbl | REUSE (AT WELL PAD) | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 41.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 12.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 4.38 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 14.38 Bbl | REUSE (AT WELL PAD) | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 53.63 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 41.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 49.88 Bbl | REUSE (AT WELL PAD) | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 41.25 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 28.13 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 28.75 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 10.63 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 56.75 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 36.88 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 26.25 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 69.38 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 162.63 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 91.88 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 14.38 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 137.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 116.25 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 87.50 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 72.50 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2137336 | Primary Facility | 2013-01-24 | Routine/Complete Inspection | No Violations Noted | On January 24, 2013, I conducted a pre-drill E&S inspection at Chevron’s Sargent site in West Bethlehem Township, Washington County. |
2182112 | Primary Facility | 2013-07-02 | Drilling/Alteration | No Violations Noted | |
2204374 | Primary Facility | 2013-09-12 | Drilling/Alteration | No Violations Noted | |
2233949 | Primary Facility | 2013-12-23 | Drilling/Alteration | No Violations Noted | |
2238488 | Primary Facility | 2014-01-07 | Drilling/Alteration | No Violations Noted | |
2243486 | Primary Facility | 2013-12-17 | Incident- Response to Accident or Event | No Violations Noted | On December 16, 2013, Chevron called the Department to report a spill on the Sargent site earlier that day; on December 17, 2013 I stopped to check the situation. During my inspection I talked primarily with Shane Barber. |
2355724 | Primary Facility | 2015-03-27 | Routine/Complete Inspection | No Violations Noted | On Friday March 27th 2015, I inspected the Sargent site in response to an extension request and made the following observations: |
2476235 | Primary Facility | 2016-03-24 | Complaint Inspection | No Violations Noted | On 3/24/16 water samples were collected for SAC 946 and bacterial count analysis in response to a complaint regarding the Sargent site. |
2476321 | Primary Facility | 2016-04-20 | Administrative/File Review | No Violations Noted | On 4/20/16, I performed an administrative review of sample results and site observation for a complaint related to the Sargent site and made the following observations:
•Water samples were found to have elevated hardness and iron levels; coliform and e. coli bacteria presence was also found indicating surface water influence. •Based on distance to nearest wells (~3000 and ~5000 feet away) and dates of most recent activity (4/19/15 and 9/4/10) as well as the above test results no oil & gas activity impact is indicated. |
2593521 | Primary Facility | 2017-05-15 | Routine/Complete Inspection | No Violations Noted | On May 15, 2017, I conducted a routine-complete inspection of the Sargent Well Site located in West Bethlehem Township, Washington County.
The Act 9 sign was in place and clearly legible at the site entrance which is secured with a locked gate. The well pad is also secured with a separate chain-linked fence and lock. The access road and the well pad are in good condition and the site is stabilized with vegetative growth. The secondary containment structure around the production tanks appears to be in good condition and functioning as intended. The gas wells appear to be in good working order and are labelled accordingly. No violations were identified during the inspection. |