37-129-28658

Well Details

Well ID: 37-129-28658
Loading map...
County: Westmoreland
Municipality: South Huntingdon Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 149319
Farm/Lease Name: SLEITH UNIT 8H
First Permit Date: 2011-08-19
Last Permit Date: 2011-08-19
Spud Date: 2011-10-03
Unconventional: Yes
Horizontal: Yes
Well Status: ACTIVE
Violations: 1
Latitude: 40.194822
Longitude: -79.742944

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2011-2 0.0 0.0 0.0 0.0 0.0 0.0
2012-1 0.0 0.0 0.0 0.0 0.0 0.0
2012-2 0.0 0.0 0.0 0.0 0.0 0.0
2013-1 0.0 0.0 0.0 0.0 0.0 0.0
2013-2 0.0 0.0 0.0 0.0 0.0 0.0
2014-1 86980.0 24.0 0.0 0.0 0.0 0.0
2014-2 404180.0 184.0 0.0 0.0 0.0 0.0
2015-02 46903.0 28.0 0.0 0.0 0.0 0.0
2015-01 54295.0 31.0 0.0 0.0 0.0 0.0
2015-03 50170.0 31.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-1 DRILLING FLUID WASTE 3.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2012-2 DRILL CUTTINGS 778.41 Tons LANDFILL 100419 ADVANCED DISPOSAL SERVICE CHESTNUT VALLEY LANDFILL MCCLELLANDTOWN PA
2012-2 DRILLING FLUID WASTE 365.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2012-2 DRILLING FLUID WASTE 135.5 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-2 FRACING FLUID WASTE 40.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-1 FLOWBACK FRACTURING SAND 30.54 Tons STORAGE PENDING DISPOSAL OR REUSE MID074259565 US ECOLOGY DETROIT MI
2014-1 FRACING FLUID WASTE 5.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 FRACING FLUID WASTE 2.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-2 FRACING FLUID WASTE 946.25 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 FRACING FLUID WASTE 4.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-2 PRODUCED FLUID 3.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
2010414 2011-10-04 No Violations Noted SPUDDED
2013220 2011-10-21 No Violations Noted Routine inspection of site due to spud notification.

Pad was in final stages of construction. Four wells had been spudded. Drill pit was installed. Construction on impoundment was ongoing. Pad and access road were rocked and stable. BMPs in place. Toes of slope to be seeded asap. No violations noted.

2021172 2011-11-17 No Violations Noted SPUDDED, MOVING YOST RIG 6 ONTO PAD.
2026110 2011-12-12 No Violations Noted Site visit was part of routine inspection.

INspection was conducted with James Grayson (Safety Chevron). All equipment was on individual containment. Some areas where pipes laid on containmnet comprimised containment. No grease or oil stained the pad. Stands were being made to keep pipes from laying on walls of containment and causing them to collapse. Pit and impoundment were sound. No freeboard issues. Slopes of pad were not vegetated but had been hydroseeded. Other outlying areas of disturbed area had good vegetative cover. No violations noted at this time.

2026740 2011-11-29 No Violations Noted YOST RIG 6 RUNNING 85/8" CSG. TO DEPTH OF 2868'. GAS SHOW @ 2338' FLARED FOR APPROX 10HRS THEN DIED DOWN.
2026763 2011-11-29 No Violations Noted SPUDDED, MOVING YOST RIG 6 ONTO PAD.
2030604 2011-12-21 No Violations Noted HORIZONTAL MARCELLUS

SPUDDED, YOST RIG 6 ON PAD, DRILLING THE 9H. PIT & HOUSEKEEPING GOOD INSPECTION CONDUCTED W/OGI J. OLSON

2037028 2012-01-17 No Violations Noted HORIZONTAL MARCELLUS

SPUDDED, YOST RIG 6 ON PAD, DRILLING THE 9H. PIT & HOUSEKEEPING GOOD INSPECTION CONDUCTED W/OGI P. WYRWAS

2037562 2012-01-27 No Violations Noted
2048807 2012-02-27 No Violations Noted HORIZONTAL MARCELLUS

SPUDDED, YOST RIG 6 ON PAD, DEPTH 7892' PIT & HOUSEKEEPING GOOD


2048831 2012-03-01 No Violations Noted HORIZONTAL MARCELLUS

SPUDDED, YOST RIG 6 ON PAD, DEPTH 7892' PIT & HOUSEKEEPING GOOD INSPECTION CONDUCTED W/OGI D. ORRAHOOD

2052256 2012-03-13 No Violations Noted HORIZONTAL MARCELLUS

SPUDDED, YOST RIG 6 ON PAD, DEPTH 7892' PIT & HOUSEKEEPING GOOD MOVED RIR BACK OVER THE WELL TO SET A PLUG ON TOP OF MUD MOTOR, (7746' - 7892).

2052487 2012-03-21 No Violations Noted This is a folow up Investigation to a spill.
2061688 2012-04-09 No Violations Noted HORIZONTAL MARCELLUS

SPUDDED, YOST RIG 6 ON PAD, DEPTH 7892' PIT & HOUSEKEEPING GOOD

2068976 2012-05-15 No Violations Noted HORIZONTAL MARCELLUS

PATTERSON RIG ON PAD, DEPTH 11794' PIT & HOUSEKEEPING GOOD

2087934 2012-07-18 No Violations Noted 7/18/2012 Back filling drill pit, and not fraced yet.
2093986 2012-08-23 No Violations Noted 4 wells drilled. No frac yet. 2 lined impoundments. E&S ok.
2108285 2012-10-04 Violation(s) Noted Company had an uncontrolled release of Frack fluids onto the ground. This happened while they were fracking the 8H well. 651551 78.54 - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth.
2113337 2012-10-05 No Violations Noted Checking on site after wellhead on 8H was dismantled and repaired; Location is covered and protected; no signs of any surface oil or material from well; annular pipe was replaced; Preparing location for remediation work;
2115816 2012-11-15 Outstanding Violations - No Viols Req'd This was a followup to a spill. No violations noted.
2120056 2012-12-03 Pending Follow up inspection to a recent brine spill. No issues noted.
2153743 2013-04-04 Outstanding Violations - No Viols Req'd Conducted a follow up inspection with Ed Bates. Chevron went over the cleanup of the well pad from the October 2012 brine release.
2166037 2013-05-13 Outstanding Violations - No Viols Req'd At the time of inspection the well appeared to be drilled but not equipped for production. The Erosion and Sedimentation plan was onsite and all associated BMPs appeared to properly installed and maintained. No observation of accelerated erosion or sedimentation observed in relation to the well pad or access road during inspection. The Department is still awaiting the results of the October 2012 clean up process to be approved. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2199776 2013-08-16 Outstanding Violations - No Viols Req'd At the time of inspection the well appeared to be drilled but not equipped for production. The Operator was in the process of reconfiguring the site for stimulation. The Erosion and Sedimentation plan was onsite and all associated BMPs appeared to properly installed and maintained. No observation of accelerated erosion or sedimentation observed in relation to the well pad or access road during inspection. The Department suggests the Operator submit sample results from the October 2012 casing failure, in order for the Department to verify cleanup was conducted to restore background. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2216357 2013-10-24 No Violations Noted At the time of inspection the Operator appears to have finished stimulation of the well. The Erosion and Sedimentation plan was onsite and all associated BMPs appeared to properly installed and maintained. No observation of accelerated erosion or sedimentation observed in relation to the well pad or access road during inspection. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2228530 2013-11-11 No Violations Noted At the time of inspection the Operator appears to have finished stimulation of the well, however no production equipment on site. During the inspection the Operator was in the process of backfilling the pit closest to the well heads, when viewed from the access road. The Erosion and Sedimentation plan was onsite and all associated BMPs appeared to properly installed and maintained. No observation of accelerated erosion or sedimentation observed in relation to the well pad or access road during inspection. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2310356 2014-10-06 No Violations Noted 10/6/2014 Produced fluids tanks diked and GPU's
2369029 2015-05-05 No Violations Noted 5/5/2015 Produced fluids tanks diked and GPU's

For data sources see[3]