X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-129-28763

Well Details

Well ID: 37-129-28763
Loading map...
County: Westmoreland
Municipality: Sewickley Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148651
Farm/Lease Name: KAMINSKY UNIT 1H
First Permit Date: 2012-03-12
Last Permit Date: 2012-03-12
Spud Date: 2012-09-11
Unconventional: Yes
Horizontal: Yes
Well Status: ACTIVE
Violations: 0
Latitude: 40.242952
Longitude: -79.692188

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-1 0.0 0.0 0.0 0.0 0.0 0.0
2012-2 0.0 0.0 0.0 0.0 0.0 0.0
2013-1 0.0 0.0 0.0 0.0 0.0 0.0
2013-2 293720.0 94.0 0.0 0.0 0.0 0.0
2014-1 507212.0 181.0 0.0 0.0 0.0 0.0
2014-2 276948.0 107.0 0.0 0.0 0.0 0.0
2015-02 51086.0 28.0 0.0 0.0 0.0 0.0
2015-01 60459.0 31.0 0.0 0.0 0.0 0.0
2015-03 53677.0 31.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-2 DRILL CUTTINGS 565.51 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2012-2 DRILLING FLUID WASTE 675.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-1 DRILL CUTTINGS 694.04 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2013-1 DRILLING FLUID WASTE 40.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2013-1 DRILLING FLUID WASTE 1.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-1 FRACING FLUID WASTE 1.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-2 FRACING FLUID WASTE 7.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2013-2 FRACING FLUID WASTE 0.25 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-2 PRODUCED FLUID 530.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 FLOWBACK FRACTURING SAND 0.74 Tons LANDFILL 100663 KELLEY RUN LANDFILL ELIZABETH PA
2014-1 FLOWBACK FRACTURING SAND 1.03 Tons STORAGE PENDING DISPOSAL OR REUSE MID074259565 US ECOLOGY DETROIT MI
2014-1 FLOWBACK FRACTURING SAND 17.81 Tons LANDFILL 100280 VALLEY LANDFILL IRWIN PA
2014-1 FRACING FLUID WASTE 11.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 FRACING FLUID WASTE 1.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-1 PRODUCED FLUID 2.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 PRODUCED FLUID 21.25 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-2 FRACING FLUID WASTE 43.75 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 FRACING FLUID WASTE 17.5 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-2 PRODUCED FLUID 687.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
2090280 2012-08-09 No Violations Noted Routine inspection. No issues noted.
2092592 2012-08-16 No Violations Noted Rotine inspection. No issues noted.
2100056 2012-09-17 No Violations Noted Spud inspection. No issues noted.
2102753 2012-09-26 No Violations Noted Routine inspection. No issues noted.
2123073 2012-11-06 No Violations Noted Horizantal Marcellus

11/6/2012 Keane rig drilling vertical portion on the 3H.

2123076 2012-12-12 No Violations Noted 12/12/2012 vertical portion of the well drilled rig gone.
2127512 2012-12-20 No Violations Noted 12/20/2012 vertical portion of the well drilled rig gone. Inspected w/OGI P. Wyrwas
2136842 2013-02-05 No Violations Noted 1/5/2013 Crown rig 8 drilling at depth of 7585'.
2136905 2013-02-07 In Compliance with Policy
2162337 2013-04-03 No Violations Noted 4/3/2013 rig moving off of pad.
2163788 2013-05-02 No Violations Noted At the time of inspection the well appeared to be drill, however the Operator indicated the well was not stimulated or equipped for production. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. The Department notes that the Operator has installed three 1 million gallon flow back tanks onsite. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2171381 2013-06-03 No Violations Noted Inspection the result of a stimulation notice received by the Department on 6/3/2013. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2188813 2013-08-02 No Violations Noted At the time of inspection the well appeared to be drilled and stimulated. The Department observed the Operator equipping the well for production. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2228554 2013-11-11 No Violations Noted At the time of inspection the well appeared to be drilled, stimulated, and equipped for production. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2242614 2014-02-05 No Violations Noted At the time of inspection the well appeared to be drilled, stimulated, and equipped for production. The Erosion and Sedimentation Plan was on site. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2242837 2014-01-23 No Violations Noted 1/23/2014 Produced fluid tanks, GPUs, and producing. Inspected w/OGI B. Stiles.
2248564 2014-02-12 No Violations Noted 2/12/2014 Produced fluids tanks, GPUs, and producing. Inspected w/OGI P. Wyrwas.
2339151 2015-01-28 No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. The Operator appeared to have regraded portions of the site in preparation for restoration. Perimeter control appear to be in place

For data sources see[3]

Chemical Data

HF Fluid Concentration Ingredient Additive Concentration Trade Name Purpose CAS number Supplier
0.03219 Hydrotreated Light Distillite 30.0 FR-66 Friction Reducer 64742-47-8 Halliburton
0.00115 Dibromoacetonitrile 5.0 EC 6116a Biocide 3252-43-5 Nalco
0.01375 Polyethylene Glycol 60.0 EC 6116a Biocide 25322-68-3 Nalco
30.0 1 10222.0 EC 6116a Biocide 1-Dibromo-3-nitrilo Nalco
0.00706 Ethylene Glycol 30.0 EC6486A Scale Inhibitor 107-21-1 Nalco
0.00698 Ethylene Glycol 30.0 EC6673W Iron Control 107-21-1 Nalco
91.24 H20 100.0 Clean Volume LLC 7732-18-5 Chevron Applachia
7e-05 Hemicellulase enzyme 15.0 GBW-30 Gel Breaker 9012-54-8 Halliburton
0.0 Ammonium Sulfate 30.0 ASP 900 Friction Reducer 7783-20-2 Nalco
0.08622 Hydrochloric Acid 15.0 15% Hcl Acid Used to open perfs 7647-01-0 Reagent/PPG
0.00144 Guar Gum 100.0 WG-36 Water Viscosifier 9000-30-0 Halliburton

For data sources see[4]

References