37-129-28805

Well Details

Well ID: 37-129-28805
Loading map...
County: Westmoreland
Municipality: South Huntingdon Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 149234
Farm/Lease Name: SABATINE-SMOUSE UNIT 2H
First Permit Date: 2012-12-07
Last Permit Date: 2012-12-07
Spud Date: 2013-01-24
Unconventional: Yes
Horizontal: Yes
Well Status: ACTIVE
Violations: 0
Latitude: 40.21318
Longitude: -79.706461

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2013-1 0.0 0.0 0.0 0.0 0.0 0.0
2013-2 0.0 0.0 0.0 0.0 0.0 0.0
2014-1 108259.0 28.0 0.0 0.0 0.0 0.0
2014-2 448444.0 184.0 0.0 0.0 0.0 0.0
2015-02 51161.0 28.0 0.0 0.0 0.0 0.0
2015-01 58097.0 31.0 0.0 0.0 0.0 0.0
2015-03 54667.0 31.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2013-2 DRILL CUTTINGS 983.77 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2013-2 DRILLING FLUID WASTE 6.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-2 FRACING FLUID WASTE 1.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-1 DRILL CUTTINGS 1.25 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2014-1 FLOWBACK FRACTURING SAND 31.33 Tons LANDFILL 100172 ARDEN LANDFILL WASHINGTON PA
2014-1 FRACING FLUID WASTE 12.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 FRACING FLUID WASTE 1.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-2 FLOWBACK FRACTURING SAND 9.05 Tons LANDFILL 100663 KELLEY RUN LANDFILL ELIZABETH PA
2014-2 FLOWBACK FRACTURING SAND 86.66 Tons RESIDUAL WASTE TRANSFER FACILITY MID074259565 US ECOLOGY DETROIT MI
2014-2 FRACING FLUID WASTE 25.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 FRACING FLUID WASTE 2.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-2 PRODUCED FLUID 1.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
2134603 2013-01-24 No Violations Noted Horiaontal Marcellus

Rocky Mountain Drilling getting set up to spud.

2134659 2013-01-25 No Violations Noted Horiaontal Marcellus

Rocky Mountain Drilling setting cellar and conductor.

2148869 2013-03-18 No Violations Noted E&S inspection. Blue-White water found in the drill cuttyings pit.
2164819 2013-04-23 No Violations Noted 4/23/2013 keane rig drilling on the 3H.
2166024 2013-05-13 No Violations Noted At the time of inspection the drill rig was on site and placed on containment. The erosion and sedimentation plan was on site. The various pit located onsite appear to be in sound condition and had the required 2' of freeboard. The Department suggest the Operator continue to inspect the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2167526 2013-05-14 No Violations Noted 5/14/2013 Keane rig skidding to the 1H
2189371 2013-07-18 No Violations Noted 7/18/2013 Sidewinder rig drilling at depth of 7767'.
2194990 2013-08-06 No Violations Noted 8/6/2013 Moving rig off of pad.
2216368 2013-10-24 No Violations Noted At the time of inspection the well was in the process of bring stimulated. The E&S plan was onsite and appeared to be installed as outlined in the plan. No sign of accelerated erosion and sedimentation in relation to the well pad or access road at the time of inspection. The Department notes that the drill pit located onsite has been back filled and the stock pile from which the material came to backfill the pit has been hydro seeded and appears to be stable. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2228547 2013-11-11 No Violations Noted At the time of inspection the well was stimulated. The E&S plan was onsite and appeared to be installed as outlined in the plan. No sign of accelerated erosion and sedimentation in relation to the well pad or access road at the time of inspection. The Department also suggests the Operator add the approved OG071 to the mail box on site. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2326219 2014-11-25 No Violations Noted At the time of inspection well appeared to be drilled

For data sources see[3]

Chemical Data

HF Fluid Concentration Ingredient Additive Concentration Trade Name Purpose CAS number Supplier
91.09 H20 100.0 Clean Volume LLC 7732-18-5 Chevron Applachia
7.157e-05 Ethylene Glycol 30.0 Iron Control A Iron Control 107-21-1 Nalco
0.00036335 Hydrotreated Light Distillite 30.0 Unislik ST 50 Friction Reducer 64742-47-8 CESI
7.578e-05 Ethylene Glycol 30.0 Scale Inhibitor A Scale Inhibitor 107-21-1 Nalco
4.4e-07 Ethylene Glycol 60.0 GBL Gel Breaker 107-21-1 Clearwater
0.00087634 Hydrochloric Acid 15.0 15% Hcl Acid Used to open perfs 7647-01-0 Reagent/PPG
1.281e-05 Dibromoacetonitrile 5.0 EC 6116a Biocide 3252-43-5 Nalco
30.0 1 10222.0 EC 6116a Biocide 1-Dibromo-3-nitrilo Nalco
0.00015369 Polyethylene Glycol 60.0 EC 6116a Biocide 25322-68-3 Nalco

For data sources see[4]