37-129-28825

Well Details

Well ID: 37-129-28825
Loading map...
County: Westmoreland
Municipality: Sewickley Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 144875
Farm/Lease Name: CRAIG LASH UNIT 1H
First Permit Date: 2012-11-29
Last Permit Date: 2012-11-29
Spud Date: 2013-01-28
Unconventional: Yes
Horizontal: Yes
Well Status: ACTIVE
Violations: 0
Latitude: 40.232472
Longitude: -79.73298

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2013-1 0.0 0.0 0.0 0.0 0.0 0.0
2013-2 0.0 0.0 0.0 0.0 0.0 0.0
2014-1 102436.0 38.0 0.0 0.0 0.0 0.0
2014-2 331690.0 184.0 32.5 184.0 0.0 0.0
2015-02 38037.0 28.0 0.0 0.0 0.0 0.0
2015-01 43365.0 31.0 0.0 0.0 0.0 0.0
2015-03 40291.0 31.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2013-1 DRILL CUTTINGS 1.0 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2013-1 DRILLING FLUID WASTE 700.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-2 DRILL CUTTINGS 717.17 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2013-2 DRILLING FLUID WASTE 6.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-2 FRACING FLUID WASTE 8.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2013-2 FRACING FLUID WASTE 2.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-1 FLOWBACK FRACTURING SAND 1.8 Tons LANDFILL 100663 KELLEY RUN LANDFILL ELIZABETH PA
2014-1 FLOWBACK FRACTURING SAND 17.6 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2014-1 FRACING FLUID WASTE 16.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 FRACING FLUID WASTE 410.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-1 PRODUCED FLUID 150.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 DRILL CUTTINGS 5.09 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2014-2 FLOWBACK FRACTURING SAND 86.82 Tons RESIDUAL WASTE TRANSFER FACILITY MID074259565 US ECOLOGY DETROIT MI
2014-2 FRACING FLUID WASTE 24.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 FRACING FLUID WASTE 1.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-2 PRODUCED FLUID 2.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 PRODUCED FLUID 32.5 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
2143434 2013-02-27 No Violations Noted Pre-operation inspection. no violations noted
2147909 2013-03-14 No Violations Noted Routine spud inspection. Found Blue-White water in drill cuttings pit.Chevron was made aware of the problem
2149825 2013-03-13 No Violations Noted Moving rig on to location.
2156471 2013-04-12 No Violations Noted Inspection the result of a citizen complaint reported to OGI Jason Brannan on 4/12/2013 at 12:30pm. During the inspection the Operator indicated that the rig was adding a substance called AIRFOAM HD which is a surfactant use to assist the removal of drill cuttings from the horizontal bore. The complaint consist of soap bubbles floating through the air approximately 1000' from the well pad area. The Operator indicated that additional defoamer was added to the drill pit to prevent the bubbles from blowing out of the pit during period of high wind. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. Various pits located on site appear to be in sound condition and have the required 2' of freeboard. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2156473 2013-04-15 No Violations Noted Inspection the result of a spill reported to the Department on 4/14/2013. The Operator reported approximately 10 gallons of drilling mud spilled onto containments. The Department notes that the Operator in in compliance with policy. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. Various pits located on site appear to be in sound condition and have the required 2' of freeboard. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2162329 2013-04-03 No Violations Noted 4/3/2013 Crown 5 drilling @ depth of 1770'.
2170270 2013-05-29 No Violations Noted At the time of inspection the drill rig was on site and placed on secondary containment. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. Various pits located on site appear to be in sound condition and have the required 2' of freeboard. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2188810 2013-08-02 No Violations Noted At the time of inspection the well was drilled to total depth, however not stimulated. During the inspection the Operator indicated that site was actively being configured for stimulation. The Erosion and Sedimentation Plan was on site. No accelerated erosion or sedimentation observed in relation to the access road or well pad area. The perimeter E&S BMPs appear to properly installed and functioning properly. Various pits located on site appear to be in sound condition and have the required 2' of freeboard. The Operator indicated that the drill pit located on site would be solidified beginning on 8/5/2013. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2241176 2014-01-31 No Violations Noted At the time of inspection the well was drilled and stimulated. During the inspection the Department observed the Operator equipping the wells for production. Unable to conduct E&S inspection ground currently covered with snow. The pit located onsite appears to be in sound condition with the required 2' of freeboard. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained.
2335192 2015-01-07 No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tanks appear to be in sound condition. The Department notes the impoundment has been backfilled. No observation of accelerated erosion or sedimentation in relation to the access road or well pad. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2365104 2015-04-10 No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tanks appeared to be in sound condition. The Department notes the Operator is in the process of restoring the site. The impoundments have been backfilled. The perimeters controls were in place and function properly. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site in maintained
2365107 2015-04-28 No Violations Noted At the time of inspection the well was drilled and equipped for production. The well apparatus and brine tanks appeared to be in sound condition. The Operator was in the process of installing the security fencing.

For data sources see[3]

Chemical Data

HF Fluid Concentration Ingredient Additive Concentration Trade Name Purpose CAS number Supplier
6.5e-07 Hemicellulase enzyme 15.0 GBW-30 Gel Breaker 9012-54-8 Halliburton
0.0008564 Hydrochloric Acid 15.0 15% Hcl Acid Used to open perfs 7647-01-0 Reagent/PPG
1.331e-05 Guar Gum 100.0 WG-36 Water Viscosifier 9000-30-0 Halliburton
7.022e-05 Ethylene Glycol 30.0 EC6486A Scale Inhibitor 107-21-1 Nalco
6.735e-05 Ethylene Glycol 30.0 EC6673W Iron Control 107-21-1 Nalco
1.273e-05 Dibromoacetonitrile 5.0 EC 6116a Biocide 3252-43-5 Nalco
30.0 1 10222.0 EC 6116a Biocide 1-Dibromo-3-nitrilo Nalco
0.00015274 Polyethylene Glycol 60.0 EC 6116a Biocide 25322-68-3 Nalco
0.00034047 Hydrotreated Light Distillite 30.0 FR-66 Friction Reducer 64742-47-8 Halliburton
91.0 H20 100.0 Clean Volume LLC 7732-18-5 Chevron Applachia

For data sources see[4]

References