34-151-24986

Well Details

Well ID: 34-151-24986
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Nimishillen Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: FLINTKOTE (ERP #1)
License Status: Active Injection
License Date: 2011-07-25
Spud Date: 1996-06-02
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1996-06-07
Well Total Depth: 4923 ft
Configuration: Vertical
Latitude: 40.900426205
Longitude: -81.28197585

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1996-05-07 Issued Date 5/7/96 Expired Date 5/7/97 Acres 0706720 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04923 Proposed Drill Depth 04923
Original Spud 1996-06-02 CONVERTED TO EOR INJECTION
Completed 1996-06-07 CONVERTED TO EOR INJECTION
Reached Total Depth 1996-06-07 CONVERTED TO EOR INJECTION
CO 1996-08-20 139 MB OPERATING CO INC GeoDate 5/7/96
Completion Report Received 1996-09-05 CONVERTED TO EOR INJECTION
Change of Owner 2000-06-30 Operator changed from 139, MB OPERATING CO INC to 6674, GREAT LAKES ENERGY PTNSHP LLC
Change of Owner 2010-04-08 Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 7578, ENERVEST OPERATING LLC
APP 2011-07-25 Proposed Formations:CLINTON, Issued Date:7/25/2011, Expired Date:7/24/2013 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:EOR, Proposed Well Class:ERP
Last Compliance Report 2011-07-27 CONVERTED TO EOR INJECTION
Construction Permit Expires 2013-07-24 CONVERTED TO EOR INJECTION
Record Last Modified 2017-02-15 CONVERTED TO EOR INJECTION

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4710 4820 32

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 195859 Gal 0 FRAC W/195,859 GAL SLICKWATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1996 MB OPERATING CO INC 2729 3204 366
1997 MB OPERATING CO INC 6853 5785 365
1998 MB OPERATING CO INC 4398 3518 365
1999 MB OPERATING CO INC 2650 1814 273
2000 RANGE RESOURCES-APPALACHIA LLC 2801 1885 365
2001 RANGE RESOURCES-APPALACHIA LLC 2763 1536 365
2002 RANGE RESOURCES-APPALACHIA LLC 2722 1340 365
2003 RANGE RESOURCES-APPALACHIA LLC 2246 1173 365
2004 RANGE RESOURCES-APPALACHIA LLC 2147 1035 365
2005 RANGE RESOURCES-APPALACHIA LLC 1796 833 365
2006 RANGE RESOURCES-APPALACHIA LLC 1721 783 365
2007 RANGE RESOURCES-APPALACHIA LLC 1519 711 365
2008 RANGE RESOURCES-APPALACHIA LLC 1420 559 365
2009 RANGE RESOURCES-APPALACHIA LLC 1152 522 365
2010 ENERVEST OPERATING LLC 1089 342 365
2011 ENERVEST OPERATING LLC 995 476 0
2013 ENERVEST OPERATING LLC 26 0 31
2014 ENERVEST OPERATING LLC 0 0 0
2015 ENERVEST OPERATING LLC 0 0 31
2016 ENERVEST OPERATING LLC 0 0 55
2017 ENERVEST OPERATING LLC 0 0 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1996 MB OPERATING CO INC Brine 296 366
1997 MB OPERATING CO INC Brine 1574 365
1998 MB OPERATING CO INC Brine 873 365
1999 RANGE RESOURCES-APPALACHIA LLC Brine 224 92
2000 RANGE RESOURCES-APPALACHIA LLC Brine 857 365
2001 RANGE RESOURCES-APPALACHIA LLC Brine 630 365
2002 RANGE RESOURCES-APPALACHIA LLC Brine 693 365
2003 RANGE RESOURCES-APPALACHIA LLC Brine 371 365
2004 RANGE RESOURCES-APPALACHIA LLC Brine 56 365
2005 RANGE RESOURCES-APPALACHIA LLC Brine 50 365
2006 RANGE RESOURCES-APPALACHIA LLC Brine 70 365
2007 RANGE RESOURCES-APPALACHIA LLC Brine 140 365
2008 RANGE RESOURCES-APPALACHIA LLC Brine 140 365
2009 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2010 ENERVEST OPERATING LLC Brine 993 365
2011 ENERVEST OPERATING LLC Brine 741
2013 ENERVEST OPERATING LLC Brine 0 31
2014 ENERVEST OPERATING LLC Brine 0 0
2015 ENERVEST OPERATING LLC Brine 0 31
2016 ENERVEST OPERATING LLC Brine 0 55
2017 ENERVEST OPERATING LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000014289 Preliminary Restoration No Violations PASSED Y WITNESSED 10/1/96 INSPECTOR BRETT FARNSWORTH DATE 10/0119/96 DATA FROM OLD VAX INFO
0016629106 2015-03-16 Enhanced Recovery Project No Violations There were no violations found at the time of inspection.
0067576990 2018-08-29 Enhanced Recovery Project No Violations I found the injection well in production on the day of my inspection. Identification signs are posted. I observed no spills or leaks. The facility and well are surrounded by locked chain link fences.
0126319020 2017-08-24 Salt Water Injection Well No Violations I performed a UIC inspection on the above location. Unloading pad and tank battery area is clear of debris. ID signs were posted. No noted violations were noted at this time.
0186646628 2019-03-28 Salt Water Injection Well No Violations I found the injection well operating during my inspection. Upon gauging the injection tubing, I observed the well was operating over the maximum allowable pressure at 1,120 psi. There was no facility operator on location. The fencing around the injection well and facility was locked. Identification signs are posted. I spoke with Mike Burkhart from Enervest. I instructed Mr. Burkhart to shut down the well until the pressure has dropped below the maximum allowable pressure. Mr. Burkhart responded to the location immediately and reduced the pressure resetting the choke on the injection pump. I gauged the injection tubing and found the pressure had reduced to 1,080 psi, which is below the maximum allowable pressure of 1,085 psi. Mr. Burkhart stated he needed to replace the existing choke with a new one. A compliance notice has been issued. Follow-up inspections will be conducted to ensure compliance with the maximum allowable pressure.
0199857412 2014-03-06 Enhanced Recovery Project No Violations No violations were found at the time of inspection.
0232394714 2015-09-14 Enhanced Recovery Project No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0235492148 2016-11-04 Enhanced Recovery Project No Violations A mini test was performed on the well. There was a pressure of 1080 pounds per square inch (psi.) on the tubing. A pressure of 330 psi. was placed on the tubing/casing annulus. There was no change in the annular pressure, during the fifteen minute test period. The well passed the test.
0266025215 2015-12-22 Enhanced Recovery Project No Violations An inspection of the injection well and surface facility found no violations.
0272009604 2018-02-26 Enhanced Recovery Project Violations Noted I was on location to inspect the facility and injection well. I found the well not in operation on the day of my inspection. The injection tubing gauged at 35 psi over the maximum allowable pressure. I observed no leaks or spills at the wellhead. An identification sign is posted next to the wellhead and at the facility. I contacted Mike Burkhart to reduce the tubing pressure. A follow-up inspection will be conducted.
0324165358 2011-06-29 Enhanced Recovery Project No Violations This well was inspected as part of a Enhanced Recovery Project. This well will be used as an injection site. There is a home located to the northwest within 200 of the injection site. Once the production well pumping unit is removed and the well is converted into an injection well, place a containment dike around the well head and fence off the site.
0328306730 2012-06-11 Enhanced Recovery Project No Violations My inspection of this well site found no violations at the time.
0378597453 2018-05-09 Salt Water Injection Well No Violations I found the injection well operating on the day of my inspection. I observed no leaks or spills. The proper identification is posted. The chain link fence is locked at the well and facility. There are no violations at this time.
0383528882 2018-03-05 Enhanced Recovery Project No Violations I was on location to assess compliance notice # -272009604. I found the pressure on the tubing reduced below the maximum allowable pressure. There are no violations at this time.
0489771947 2016-07-15 Enhanced Recovery Project Violations Noted The well was found operating over the maximum allowable injection pressure. Michael Burkhart was notified. The pump rate was turned down, immediately. The rate was lowered until the injection pressure fell below the maximum allowed.
0515855012 2012-11-26 Enhanced Recovery Project No Violations I inspected the Flintkote (ERP #1) No. 36 (34151249860000) injection well on November 26, 2012; I was accompanied by Steve Ochs. There were no violations at the wellhead or at the brine tanks.
0555816254 2014-04-21 Enhanced Recovery Project No Violations An inspection of the well and injection facility found no violations.
0585488760 2017-11-01 Enhanced Recovery Project Violations Noted I found the UIC facility in good repair on the day of my inspection. There is an identification posted at the facility. There are identification signs posted at the well. There is a locked chain link fences around the well and facility. I observed no leaks or spills. The injection well pressure is above the maximum allowable. A compliance notice has been issued. I spoke with Mike Burkhart with Enervest to reduce the pressure immediately. A follow-up inspection will be conducted 11/2/2017.
0676281884 2012-11-26 Enhanced Recovery Project No Violations My inspection of the injection facility and well was accompanied by Ryan Channell. There were no violations found at the time of inspection.
0803198022 2016-03-31 Enhanced Recovery Project No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0845056256 2014-09-16 Enhanced Recovery Project No Violations No violations were found at the time of inspection.
0904864693 2013-12-27 Enhanced Recovery Project No Violations There were no violations at the time of inspection.
1185947039 2019-02-14 Enhanced Recovery Project No Violations I found the injection well in operation during my inspection. The chain link fence around the injection well is locked. Identification signs are posted. I observed no leaks or spills.
1210358566 2013-07-15 Enhanced Recovery Project No Violations No violations were found at the time of my inspection.
1215859945 2014-12-12 Enhanced Recovery Project No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1231699199 2012-03-30 Enhanced Recovery Project No Violations I witnessed the testing of the buried flow line. The flow line held at 1400 PSI for 18 minutes - test passed.
1310399197 2014-07-24 Enhanced Recovery Project No Violations An inspection of the well and injection facility found no violations.
1326999444 2012-01-18 Enhanced Recovery Project No Violations Rick Kepler (Enervest) called me for a Mechanical Integrity Test (MIT). When I arrived at the site, a new Halliburton PLT packer was run by Bishop Well Service on 2.375 EUE tubing and set at 4663 (47 above the top perforation) with 12,000 pounds of compression on the packer and 6,000 pounds of tension on the slips. J Hawk Water Service pumped and circulated 50 barrels of packer inhibitor in the annulus. The annulus was pressured up to 1140 PSI. The test was started at 1140 PSI and ended at 1140 PSI after 19 minutes. The MIT PASSED. Rick Kepler will submit a tubing tally to Tom Tomastik at the Columbus office. The allowable injection pressure for this well is 1085 PSI.
1371702128 2018-10-24 Salt Water Injection Well No Violations I found the injection well operating on the day of my inspection. The fence around the well and facility was locked. Identification signs are posted. I observed no leaks or spills.
1509630067 2017-11-02 Enhanced Recovery Project No Violations I was on location to assess compliance notice # -585488760. I found the pressure on the injection well reduced. Identification signs are posted at the well and facility.
1509927739 2017-06-22 Enhanced Recovery Project No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1567960883 2017-03-29 Enhanced Recovery Project No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1757536063 2015-05-29 Enhanced Recovery Project No Violations The well and surface facility were inspected. There were no violations found at the time of inspection.
2100804527 2017-12-15 Salt Water Injection Well No Violations I found the injection and facility in good repair on the day of my inspection. I observed no leaks or spills. An identification sign is posted at the facility and well. The facility and well are secure with a locked chain link fence. There are no violations at this time.
2135936915 2014-05-30 Enhanced Recovery Project No Violations An inspection of the well and injection facility found no violations.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0272009604 US-OH-122819 2018-03-21 9-5-10(D) Exceeding maximum allowable injection pressure
0489771947 US-OH-125363 2016-10-17 Exceeding maximum allowable injection pressure
0585488760 US-OH-126576 2018-01-08 9-5-10(D) Exceeding maximum allowable injection pressure

For data sources see[9]

References