Well Details

Well ID: 34-007-24486
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DAVID R HILL INC
Well Pad ID:
Farm/Lease Name: BLACKSON C
License Status: Producing
License Date: 2008-07-03
Spud Date: 2009-01-05
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2009-01-13
Well Total Depth: 2954.00 ft
Configuration: Vertical
Latitude: 41.930000
Longitude: -80.650000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-07-03 Proposed Formations:ORISKANY/CLINTON/MEDINA, Issued Date:7/3/2008, Expired Date:7/3/2009 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-01-13
Completion Report Received 2009-03-16
Construction Permit Expires 2009-07-03
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-04 2708 2800 86
2708 2800 86
2708 2800 86

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 72500 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 DAVID R HILL INC 22737.00 0.00 253
2010 DAVID R HILL INC 28288.00 36.00 365
2011 DAVID R HILL INC 34759.00 179.00 365
2012 DAVID R HILL INC 43366.00 222.00 366
2013 DAVID R HILL INC 37471.00 140.00 365
2014 DAVID R HILL INC 38886.00 160.00 365
2015 DAVID R HILL INC 33078.00 254.00 365
2016 DAVID R HILL INC 35451.00 105.00 365
2017 DAVID R HILL INC 21622.00 81.00 365
2018 DAVID R HILL INC 27367.00 151.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 DAVID R HILL INC Brine 244 253
2010 DAVID R HILL INC Brine 165 365
2011 DAVID R HILL INC Brine 360 365
2012 DAVID R HILL INC Brine 108 366
2013 DAVID R HILL INC Brine 218 365
2014 DAVID R HILL INC Brine 223 365
2015 DAVID R HILL INC Brine 217 365
2016 DAVID R HILL INC Brine 106 365
2017 DAVID R HILL INC Brine 131 365
2018 DAVID R HILL INC Brine 277 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0032411822 2017-03-29 Production Wells No Violations Complaint# 5561, Chief Flanigan. My inspection of this well found the well was equipped with a plunger lift system. There was a active domestic hook-up off of the production casing head. I found no compliance issues with this well.
0413812412 2018-02-12 UrbanProduction Wells Violations Noted The lease road initially utilized the landowners driveway and then was graveled up to the wellhead and tank battery. The well was located in North Kingsville Village which is designated as an Urbanized Permit Condition Area. The tank battery consisted of one (1) 140 bbl. stock tank, one (1) 35 barrels poly brine tank, one vertical separator and one (1) gas measurement meter. The tank battery was surrounded with an earthen dike and an eight (8) foot high chain link fence. The gate was not locked and was left open. The load lines were plugged, but not locked. The inspection hatch on the top of the tank was not fastened down and left open. The required charcoal filter was not present. The identifying signage was posted on the fence, but was not compliant with Urbanized Permit Condition Area rules. The gas meter had a paper chart indicating current gas sales for the production period. The load lines, for the oil and brine drains, were plugged but not locked. The well was operated as a plunger lift. The tubulars, as seen at the surface, were 8.625 surface casing, 4.5 production casing and 1.5 tubing. The 8.625 X 4.5 annular space was open without any indication of flow. The casing and tubing both had approximately 550 psi on the respective gauges. A domestic regulation manifold was connected to the 4.5 casing. The well head was surrounded with a eight (8) foot chain link fence and access gate. The access gate was unlocked and open. There was non-compliant I. D. signage posted on the wellhead fencing. In order to bring the Blackson # 1 well into compliance with OAC 1501:9-9-05 ( E ) the Owner shall: 1.) place locks on the gates and load lines, 2.) post identifying signage that is compliant with the rules for Urbanized Areas, 3.) equip the tanks with a charcoal filter, lightning arrestor and low pressure relief valve as needed. The above list corrective measures shall be completed and approved by a DOGRM Inspector by 5/2/2018. If you have any questions and /or comments, pl
1512422628 2017-12-04 Production Wells No Violations I inspected this well pursuant to Complaint # 5561. The complainant has previously reported that they felt that they were not receiving the proper royalty payments for this well, located on their property. Upon inspection, I observed the following: a wellhead with plunger-lift and associated tank battery in separate chain-link enclosures, The well was in active production. Insurance and bonding is current. Production reports were current. I I contacted David Hill and he advised that they have provided the complainants with production documentation in an attempt to resolve the dispute. I met with the complainants who raised quesitons about the veracity of the production data. I advised the complainant that they would have to resolve the royalty dispute with the owner as a civil matter. There were no noted violations.
1794199839 2009-11-03 Preliminary Restoration No Violations no violations .
1894829428 2018-11-08 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 413812412, regarding urban requirements for identification, locks and tanks. The well was equipped with a plunger lift assembly and in production. The well was fenced but needed a lock on the man door. There was non-compliant I. D. signage posted on the well fencing. The tank battery consisted of one 140 BBL tank, one 50 BBL poly brine tank, and a vertical separator. The tank battery fence door still needed a lock installed. The load lines were plugged, but still needed locks installed. The inspection hatch on the top of the tank was closed. The required charcoal filter was not present. The identifying signage was posted on the fence, but was not compliant with Urbanized Permit Condition Area rules.

David R. Hill, Inc. still needs to: 1.) Install locks on the man door fences and load lines 2.) Post identifying signage that is compliant with the rules for Urbanized Areas 3.) Equip the tanks with a charcoal filter, lightning arrestor and low pressure relief valve as required per OAC 1501:9-9-05 ( E ).

32411822 2017-3-29 0:00: PW No Violations
413812412 2018-2-12 0:00: UP No Violations
799869702 2019-5-8 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0413812412 US-OH-124396 2018-06-22 ID (a-i)
0413812412 US-OH-124397 2018-06-22 LOCKS
0413812412 US-OH-124398 2018-06-22 TANKS (a-i)

For data sources see[9]