34-059-24285

Well Details

Well ID: 34-059-24285
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Spencer Township
Operator Name: EQT PRODUCTION COMPANY
Well Pad ID: US-OH-000766
Farm/Lease Name: DOBECK
License Status: Plugged Back
License Date: 2013-05-10
Spud Date: 2013-09-23
Spud Drilling Contractor: PIONEER DRILLING
Final Drill Date: 2013-11-06
Well Total Depth: 6950.00 ft
Configuration: Vertical
Latitude: 39.910000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-05-10 Proposed Formations:BLACK RIVER, Issued Date:5/10/2013, Expired Date:5/10/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Plugged Back 2013-11-06
Reached Total Depth 2013-11-06
Construction Permit Expires 2015-05-10
Completion Report Received 2017-11-09
Record Last Modified 2017-11-14

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1016815048 2020-9-15 0:00: PB No Violations 0.20
-1065095661 2020-3-23 0:00: PB No Violations 0.50
-1106150234 2019-1-24 0:00: PB No Violations 0.50
-1168435986 2018-10-18 0:00 PB No Violations 0.70
-1214568516 2020-1-9 0:00:0 PB No Violations 0.30
-125571932 2019-4-26 0:00: PB No Violations 0.20
-1268077468 2019-5-2 0:00:0 PB No Violations 1.00
-1327698648 2019-10-10 0:00 PB No Violations 0.50
-1336715973 2018-4-25 0:00: PB No Violations 4.00
-134265985 2020-2-4 0:00:0 PB No Violations 1.50
-1359145702 2019-12-9 0:00: PB No Violations 0.30
-1367081357 2019-3-5 0:00:0 PB No Violations 0.20
-1388264659 2020-5-11 0:00: PB No Violations 0.70
-1443707716 2020-9-8 0:00:0 PB No Violations 4.00
-1543938987 2020-6-30 0:00: PB No Violations 4.30
-1551291373 2019-10-31 0:00 PB No Violations 1.00
-1596187029 2018-8-15 0:00: PB No Violations 0.50
-1614038350 2019-11-26 0:00 PB No Violations 0.50
-1636511036 2020-1-2 0:00:0 PB No Violations 0.50
-1724152022 2018-8-23 0:00: PB No Violations 2.00
-1781219135 2020-9-14 0:00: PB No Violations 3.70
-1782887963 2015-12-7 0:00: DD No Violations 0.50
-1784478016 2020-5-20 0:00: PB No Violations 4.20
-1818028162 2019-11-26 0:00 PB No Violations 1.00
-1835202398 2020-9-30 0:00: PB No Violations 6.50
-1853920194 2020-5-18 0:00: PB No Violations 7.10
-1906411726 2019-9-4 0:00:0 PB No Violations 3.00
-1912833528 2019-7-24 0:00: PB No Violations 1.00
-1915462523 2019-12-20 0:00 PB No Violations 0.20
-1924015422 2020-5-19 0:00: PB No Violations 4.20
-1940999795 2018-8-27 0:00: PB No Violations 1.10
-1980705252 2020-6-17 0:00: PB No Violations 4.00
-2029849942 2020-6-3 0:00:0 PB No Violations 0.10
-2034958497 2018-4-23 0:00: PB No Violations 6.50
-20412095 2020-1-30 0:00: PB No Violations 0.50
-2087811227 2020-6-16 0:00: PB No Violations 3.00
-2089626705 2013-12-11 0:00 DD No Violations
-2118031944 2018-3-28 0:00: PB No Violations 3.00
-304923872 2018-5-31 0:00: FR No Violations 0.50
-332399849 2018-8-1 0:00:0 PB No Violations 4.00
-343565202 2018-3-19 0:00: DD No Violations 1.00
-368071576 2018-4-18 0:00: PB No Violations 8.00
-37909800 2019-12-9 0:00: PW No Violations 0.50
-38848777 2014-9-17 0:00: PL No Violations 0.10
-421390854 2018-5-1 0:00:0 PB No Violations 3.00
-425417218 2015-4-6 0:00:0 DD No Violations 1.00
-453106695 2020-3-3 0:00:0 PB No Violations 0.50
-456027309 2020-5-27 0:00: PB No Violations 2.50
-464877520 2018-8-24 0:00: PB No Violations 1.10
-488170688 2020-7-22 0:00: PB No Violations 6.20
-535147290 2020-10-8 0:00: PB No Violations 2.80
-543594018 2018-8-23 0:00: PB No Violations 4.50
-641114669 2017-8-1 0:00:0 DD No Violations 1.00
-643924680 2019-8-6 0:00:0 PB No Violations 0.20
-650839104 2018-6-4 0:00:0 PB No Violations 2.00
-665607534 2018-10-22 0:00 PB No Violations 0.10
-675818638 2019-3-25 0:00: PB No Violations 4.70
-778386015 2020-7-8 0:00:0 PB No Violations 2.00
-782251842 2019-3-28 0:00: PB No Violations 1.00
-789398091 2020-9-23 0:00: PB No Violations 1.30
-794310955 2019-3-13 0:00: PB No Violations 1.00
-807501086 2014-3-3 0:00:0 DD No Violations
-868876256 2020-7-7 0:00:0 PB No Violations 1.50
-895595794 2020-5-26 0:00: PB No Violations 6.50
-901334791 2018-3-5 0:00:0 DD No Violations 0.90
-910784646 2018-4-27 0:00: PB No Violations 2.50
-918877551 2020-3-31 0:00: PB No Violations 1.00
-940611828 2013-11-18 0:00 DD No Violations
-942838906 2020-7-21 0:00: PB No Violations 1.00
-959317609 2018-8-20 0:00: PB No Violations 6.40
-988819233 2020-1-3 0:00:0 PB No Violations 0.50
0038848777 2014-09-17 Preliminary Restoration No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A
0062103232 2018-03-26 Drill / Deepen / Reopen No Violations
0120336331 2018-08-21 Plug / Plug Back No Violations Fountain Qual Rig 8 tripped within the 9.625-inch diameter production casing and tagged the cement plug at 1125 feet. I called John Sandy with EQT Construction section and made him aware that all drawings and plans for the pad final restoration shall be submitted to ODNR Engineering section.
0228131856 2019-03-21 Plug / Plug Back No Violations The Fountain Quail rig 8 (Schramm 250) had rigged up Keystone Energy wireline services and ran a camera in to the top of the Baker cement retainer at 195 feet. The camera revealed no bubbling at the top of the 9 5/8-inch cement retainer and pulled back to 180 and there was bubbling from the gas. Universal well services were in to set a gas block cement plug from 195-120 feet with 30 sacks of Class A cement + 5% salt+ .75%CFL-
0289319637 2017-03-22 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed the well the well was equipped with a Cactus casing wellhead with valves in the closed position with no flowline installed. Production equipment included a sand trap, a GP Unit, a sand purge tank, 8-400 barrel tanks, 140 barrel tank and a 100 barrel purge tank all within containment and a gas combustor and will be shared with the 34059242800100 Dobeck 580015. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. Fluid present in the cellar was field tested revealing a pH of 7 and chlorides of < 33 parts per million (ppm). 6 inches of fluid was present in the tank containment and was also field tested revealing tested revealing a pH of 7 and chlorides of < 33 ppm. Upon leaving the location I met with the land owner Mr. Dobeck who stated he has had his mineral released.
0304923872 2018-05-31 Final Restoration No Violations The purpose of my inspection was a status check. During my inspection the cellar was 2 feet from being full of rain water and bubbles could be seen coming to surface of the water. I spoke with Rick Green with EQT and asked that he meet me on location with a water truck and confirm where the bubbling was coming from. While utilizing my Ventis Pro 4 gas detector 0 LEL was recorded and no smells of gas were present. Mr. Green agreed to meet me at the wellsite on 6/4/18.
0332399849 2018-08-01 Plug / Plug Back No Violations During my inspection Keystone Energy was rigged up on location with their camera. The camera was tripped within the 9.625-inch diameter casing and did not see any bubbling or gasing within the casing. The well will be shut in overnight for monitoring and the rig will skid over to 3405924280.
0343565202 2018-03-19 Drill / Deepen / Reopen No Violations On the day of my inspection accompanied by ODNR Inspector Jeff Adams, I witnessed the well was equipped with a Cactus casing wellhead with valves in the closed position. All production equipment has been disassembled and removed from location. Conserv Incorporated Rig #6 was onsite with plans to rig up and commence plugging of the well later this week.
0368071576 2018-04-18 Plug / Plug Back No Violations On 3/27/18 Conserv Incorporated set a cast iron bridge plug at 6253 feet within the 5.5 inch diameter production casing. During my inspection today Conserv tripped 2.375 inch diameter tubing down to 6250 feet and set a 500 foot plug from 6250 feet to 5750 feet. The plug consisted of 11.1 barrels of class A cement. A 6 percent gel spacer was pumped and the tubing was pulled up to 5225 feet. A class A cement plug was pumped from 4900 feet to 5225 feet. A gel spacer was pumped and a the tubing was pulled up to 3800 feet where a 300 foot class A cement plug was set from 3500 feet to 3800 feet.
0421390854 2018-05-01 Plug / Plug Back No Violations Conserv tripped in hole with the 2.375 inch diameter tubing and tagged the plug set 4/30/18 from 1750 feet to 1250 feet. The plug was tagged at 1304 feet. Some of the cement was squeezed through the perforations to fill the void on the backside of the 9.625 inch casing. A 6 percent gel spacer was pumped from 1304 to 500 feet. The 2.375 inch tubing was pulled up to 500 feet and a class A cement plug was pumped from 500 feet to surface.
0425417218 2015-04-06 Drill / Deepen / Reopen No Violations On the day of my inspection accompanied by ODNR Inspector Matt Fulk, I witnessed that the wells have not been completed and the production equipment has been installed including a sand trap, a GP Unit, a combustor, a sand purge tank, 8-400bbl tanks and 140bbl tank shared with the 34059242800100 Dobeck 580015 with no flowline or salesline. Site inspection revealed violations.
0464877520 2018-08-24 Plug / Plug Back No Violations The inspection was conducted under replugging operations due to Compliance Notice number -650839104. EQT had ran a bond log this morning revealing that there would be no free pipe coming from the 13 3/8-
0543594018 2018-08-23 Plug / Plug Back No Violations The inspection was conducted under re-plugging operations due to Compliance Notice number -650839104. Quail Drilling rig #8 is on site and KLX is on site to cut the 9 5/8-- circulation. The rig broke circulation and started to cut the pipe. The well quit circulating. The pipe was cut at this point and retrieved the tool out of the well. The casing crew was on the way to trip the casing out of the well.
0623219531 2018-08-02 Plug / Plug Back No Violations On 8/1/18 the well was shut in overnight to see if gas would accumulate. During my inspection the Fountain Qual Rig 8 removed the Kelly off the drill pipe and checked the drill pipe for gas readings. No readings were recorded. A night cap was installed with a pressure gauge. The rig crew continued to work on skidding the rig to 3405924280. The cellar was power washed and water was removed with super sucker water truck.
0641114669 2017-08-01 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed the well the well was equipped with a Cactus casing wellhead with valves in the closed position with no flowline installed. Production equipment included a sand trap, a GP Unit, a sand purge tank, 8-400 barrel tanks, 140 barrel tank and a 100 barrel purge tank all within containment and a gas combustor and will be shared with the 34059242800100 Dobeck 580015. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. On July 27, 2017 I received a call from Mark Van Tyne of Pin Oak Energy who stated that Pin Oak may be acquiring the Dobeck 580015 & Dobeck 580014 from EQT. I met with the land owner Mr. Dobeck who stated he has met with Pin Oak representatives and they are in talks.
0650839104 2018-06-04 Plug / Plug Back Violations Noted The purpose of my inspection was to determine why the rain water within the cellar was rapidly bubbling. Plugging operations for the well were completed on 5/1/2018. During my inspection, I was accompanied by EQT company man Rick Green. Mr. Green had a water truck arrive on location to remove the water from the cellar. The water was removed down to the top of the 9.625 inch diameter intermediate casing which appeared to be the source of the bubbling. The steel plate was removed from the top of the casing and gas appeared to be bubbling up through the water within the casing. Mr. Green held his gas monitor over the 9.625 inch casing and recorded an LEL of 15. A plumb bob was lowered into the 9.625 inch casing and the top of the cement surface plug was tagged at 16 feet from surface. I asked Mr. Green to have EQT present a plan to ODNR for approval or denial that would eliminate the flow of gas to surface. EQT shall correct the failed plugs and prevent the escape of natural gas into the atmosphere.
0665607534 2018-10-22 Plug / Plug Back No Violations The well had been plug and does not appear to be leaking.
0675818638 2019-03-25 Plug / Plug Back No Violations

-inch stainless steel ball was pumped by Conserv Service company pump truck. The tool was set, then the string was pulled out of the hole. Conserv will pump cement from top down with gas block cement. 140-0 with 106 sacks of Class A cement with gas block additive which consisted of .1 gallon per sack of c-24l, .2 gallon per sack of c-17l, .05 gallon per sack of c-37l and .05 gallon per sack of c-41l. two samples were obtained of cement slurry and was weighed with scales to 15.6 lb. per gallon. The fresh water had a PH OF 6 and a temperature of 49 degrees.

0713495836 2019-04-01 Plug / Plug Back No Violations The inspection revealed the well had a Cactus company night cap installed and the pressure was at 23 psi. The phone calls were made to set up a meeting with EQT, ODNR and the Dobecks.
0777980161 2018-07-31 Plug / Plug Back No Violations The purpose of my inspection was a status check on remediating a leaking plugged well. During my inspection I spoke with EQT consultant Dave Hancock and he stated that on 7/30/18 the hole was blown down to 770 feet and Cardo Services rigged up with their camera and tripped in the 9.625-inch diameter casing to verify where the gas was leaking into the wellbore and no bubbling was detected. A copy of the camera run was reviewed. EQT made the decision to blow the hole down deeper to prepare to trip back in with the camera on 8/1/18.
0782251842 2019-03-28 Plug / Plug Back No Violations The inspection revealed the well is leaking a minimal amount of gas and is barley bubbling. I was accompanied by Mike Mooreland District Supervisor for the southeast region and Rick Green and Beau Fry of EQT.
0794310955 2019-03-13 Plug / Plug Back No Violations The inspection is due to a drill out of a plugged well from 2018. The gas was bubbling thru the 13 3/8 casing and cement. The inspection revealed the Fountain Quail rig 8(Schramm 250) is moved over the well and is rigged up to the shaker and tank. They attached to the 13 3/8-inch flange. They are getting rigged up and will start drilling this afternoon.
0803965431 2015-04-22 Drill / Deepen / Reopen No Violations

-400bbl tanks and 140bbl within containment and a gas combustor. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. The water impoundment was securely fenced in with a life preserver at the locked gate.

0807501086 2014-03-03 Drill / Deepen / Reopen No Violations On the day of my inspection, I witnessed the Pioneer Rig #70 getting rigged down and mobilizing to the NCD3 Pad in Spencer Township.
0863309937 2018-08-22 Plug / Plug Back No Violations The inspection was conducted under re-plugging operations due to Compliance Notice number -650839104. Quail Drilling rig #8 is on site and Haliburton is on site to set a Composite bridge plug at 553 feet. The tool is on the bottom of 13 joints of 4.5-inch drill pipe at 16.60 lb. per foot. B J services is on site with cement equipment and set the composite tool and placed a 200-foot cement plug with 73 sacks of regular class A cement with Gas Block cement on the composite. B J set the composite by pumping on the tool and the rig pulled all pipe out. The rig ran in with open ended 4.5-inch drill pipe and set the cement plug on top of the composite plug. The rig then pulled out 4.5 inch drill pipe and shut down.
0881274820 2019-03-15 Plug / Plug Back No Violations Fountain Quail rig 8 (Schramm 250) has drilled to 180 feet with a 12 3/8 tri-cone bit inside the 13 3/8--cone bit and ran inside the 9 5/8-inch casing from 180-225. The rig tripped out of the well and ran a 12 3/8-inch mill in to clean up the inside of the 13 3/8-inch casing. The rig made several soap sweeps to clean up the hole. Marshall, Miller & Associates ran a camera into the well to a depth of 227 feet. The video showed the 9 5/8 casing was to one side of the 13 3/8-inch casing. The back side of the 9 5/8-inch casing was gassing at 181 feet and the inside of the 9 5/8-inch casing was gassing at 227.
0901334791 2018-03-05 Drill / Deepen / Reopen No Violations Accompanied Guernsey County Inspector Doug Bennett, Reference his Report for further details
0910784646 2018-04-27 Plug / Plug Back No Violations Conserv tripped within the 9.625 inch diameter casing with 2.375 inch tubing and set a 500 foot class A cement plug from 1950 feet to 2450 feet. The plug was set a crossed the perforations from 4/27/18 that were set from 2280 feet to 2290 feet and from 2150 feet to 2160 feet. The tubing was tripped out of the cement. The rig will wait on cement and tag the plug before continuing.
0940611828 2013-11-18 Drill / Deepen / Reopen No Violations On the day of my inspection, I found the top hole rig Alpha Hunter #4 was being disassembled for a rig move.
0959317609 2018-08-20 Plug / Plug Back No Violations The inspection was conducted under re-plugging operations due to Compliance Notice number -650839104. The Fountain Quail rig 8 was over well and had 9 5/8--block system. The yield is 1.19 cuft per sack.
1003799043 2020-6-26 0:00: PB No Violations 1.10
1026250347 2014-09-18 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A
1075459493 2016-04-27 Production Wells No Violations On the day of my inspection I witnessed the well the well remains in Temporary Inactive status, and equipped with a Cactus casing wellhead with valves in the closed position with no flowline installed. Production equipment included a sand trap, a GP Unit, a sand purge tank, 8-400bbl tanks and 140bbl within containment and a gas combustor and will be shared with the 34059242800100 Dobeck 580015. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. The impoundment has been closed and restored to grade with seed and mulch in place.
10826515 2020-1-9 0:00:0 PB No Violations 0.20
1094068335 2020-10-9 0:00: PB No Violations 2.30
1106150234 2019-01-24 Plug / Plug Back No Violations The inspection revealed that the rear of the rig was placed over the square cellar of the Dobeck #14. The well is still gassing.
1124349306 2019-12-19 0:00 PW No Violations 0.20
1136341086 2019-5-2 0:00:0 PB No Violations 0.50
1157168480 2018-04-26 Plug / Plug Back No Violations Conserv pumped a class A cement plug from 2504 feet 2804 feet a crossed the 5.5 inch casing cut. The plug was set 52 feet within the 5.5 inch diameter casing and 248 feet within the 9.625 inch diameter casing. The tubing was removed from hole. Conserv Wireline tripped in with a gauge tool to determine if the cast iron bridge plug would be able to get down to roughly 2450 feet. The gauge tool successfully made it down to the desired depth and it was tripped out of hole. The cast iron bridge plug was rigged up to wireline and ran down to 2450 feet and was set successfully within the 9.625 inch diameter casing. Wireline was tripped out of hole and tripped back in and set 10 perforations within the 9.625 inch diameter casing from 2280 feet to 2290 feet and then 10 more shots from 2150 feet to 2160 feet.
1168435986 2018-10-18 Plug / Plug Back No Violations The inspection is conducted as a follow-up to the plugging operations that were completed. Brent Bear and I were on site looking at the plugged well. There is a no bubbling on the large flange casing spool. The cellar has water on the floor. The cement has been verified at the top that there is no bubbling. The large spool will have to be removed.
1175786475 2020-5-15 0:00: PB No Violations 4.60
1176385757 2020-8-7 0:00:0 PB No Violations 0.50
1185820626 2020-5-14 0:00: PB No Violations 3.50
1202172559 2020-8-21 0:00: PB No Violations 2.50
120336331 2018-8-21 0:00: PB No Violations 3.50
1219929291 2013-10-28 Drill / Deepen / Reopen No Violations On the day of my inspection, I witnessed the Alpha Hunter Rig #4 setting idle while Halliburton broke circulation with fresh water then displaced 1180 sacks of Halcem cement in the 13.375 casing.
1336715973 2018-04-25 Plug / Plug Back No Violations Conserv Incorporated wireline truck was rigged up on location. During my inspection a bond log was ran to verify cement bond on the backside of the 9.625 inch diameter casing from 2650 feet to surface. The bond log was reviewed and EQT decided to perforate the areas with the weakest bond. Conserv tripped back within the 9.625 inch casing with 10 shots and perforated the casing from 2600 feet to 2590 feet. Wireline was tripped out of hole and the 2.375 inch diameter tubing was tripped back in hole to 2804 feet.
1367081357 2019-03-05 Plug / Plug Back No Violations The inspection revealed that the water was frozen in the cellar and could not tell if the well was gassing.
1392050454 2020-8-3 0:00:0 PB No Violations 1.50
1392934171 2014-02-20 Drill / Deepen / Reopen No Violations On the day of my inspection, I witnessed the Pioneer Rig #70 drilling at a depth of 6800 and were about to land the curve for the lateral, my walk around site inspection revealed no issues.
1417828190 2020-9-2 0:00:0 PB No Violations 3.00
1507594363 2020-10-1 0:00: PB No Violations 6.80
1520259946 2018-03-05 Drill / Deepen / Reopen No Violations On the day of my inspection accompanied by ODNR Inspector Ryan Armstrong, I witnessed the well was equipped with a Cactus casing wellhead with valves in the closed position with no flowline installed. Production equipment included a sand trap, a GP Unit, a sand purge tank, 8-400 barrel tanks, 140 barrel tank and a 100 barrel purge tank all within containment and a gas combustor and will be shared with the 34059242800100 Dobeck 580015. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. . A plug permit was issued on 1/25/18. I met with land owner Phil Dobeck and discussed the upcoming plugging of the wells. A call was placed to EQT Supervisor Rick Green and requested an update on when plugging will commence. Mr. Green returned my call and stated that a rig should arrive later this week and deconstruction of the production equipment should begin later today.
1521473305 2018-03-19 Drill / Deepen / Reopen No Violations On the day of inspection I accompanied ODNR Inspector Doug Bennett. Please see his report for details.
1524832354 2018-04-24 Plug / Plug Back No Violations During my inspection Conserv Incorporated hooked up to the 5.5 inch diameter casing and circulated the inside and the backside of the 5.5 inch diameter casing with 200 barrels of fresh water. Conserv pulled up on the 5.5 inch casing and the casing was free. 2752 feet of the 5.5 inch diameter production casing was removed from hole.
1525267069 2018-04-30 Plug / Plug Back No Violations Conserv Incorporated tripped within the 9.625 inch casing with the wireline perforating gun and 10 shots spread out in 10 feet. The casing was perforated at 1710 feet to 1700 feet. The wireline was tripped from hole and 10 more shots were wired up. The wireline tripped back in the 9.625 inch casing and shot 10 shots from 1660 feet to 1650 feet. Conserv tripped the 2.375 inch tubing back in hole and set a 500 foot plug a crossed the perforations 1750 feet to 1250 feet. The plug consisted of 37.9 barrels of class A cement.
1531324568 2018-07-11 Plug / Plug Back No Violations The purpose of my inspection was a follow up on compliance notice -650839104. The compliance notice was a result of a failed plug job that left the well leaking gas within the 9.625--plug the well. A move in date has not yet been given. I contacted landowner Phil Dobeck to make him aware that EQT plans and is required to move back in to re-plug the well. During my inspection today the well remains to gas and EQT has not moved in at this time.
1532895344 2018-07-26 Plug / Plug Back No Violations The purpose of my inspection was a status check on re-plugging operations. During my inspection Fountain Qual top hole rig number 8 was rigged up on location preparing to drill out the cement plugs. The rig was being service and not in operation. A walk around was completed with David Hancock, a consultant for EQT. Mr. Hancock stated that the would like to be started drilling out the cement plugs by this afternoon.
1533136128 2018-07-30 Plug / Plug Back No Violations The purpose of my inspection was a status check on remediating a leaking plugged well. During my inspection the Fountain Quail Rig 8 was in the process of rigging up an air compressor to prepare to blow the hole down to remove fresh water from within the 9.625-inch diameter casing to remove some hydrostatic pressure. The well was not leaking at that time, so they attempted to remove hydrostatic pressure to encourage the well to leak to verify the problem area.
1533357209 2020-10-7 0:00: PB No Violations 3.20
1534858304 2018-08-20 Plug / Plug Back No Violations Fountain Qual Rig 8 was rigged up on location with 4.5-inch diameter drill pipe weighing 16.6 pounds per foot at 1343 feet in depth within the 9.625-inch diameter second intermediate casing. BJ Services rigged up on location with a pump truck and bulk cement truck. A pre-job safety meeting was held with all personnel on location. BJ pumped 375 barrels of 6 percent gel at 9 pounds per gallon and the rig pulled up 500 feet. BJ pumped an additional 125 barrels of gel and the rig tripped back into 1350 feet and BJ pumped 125 barrels of gel and 15.25 barrels of Class A cement weighing 15.6 pound per gallon and displaced with 16.2 barrels. The drill pipe was tripped up out of the cement.
1535461577 2018-08-22 Plug / Plug Back No Violations During my inspection I attended the pre-job safety meeting with ODNR Pat Shreve, EQT, Fountain Qual Rig Hands, Halliburton, and BJ Services. Following the meeting Halliburton rigged up their composite bridge plug to the drill pipe. Fountain Qual tripped the drill pipe into 551 feet in depth within the 9.625-inch diameter intermediate casing. BJ Service rigged the pump truck up to the drill pipe and with the assistance of the Halliburton tool hands the composite drill plug was set at 551 feet. The drill pipe was tripped out of hole and the setting tool was removed. The drill pipe was tripped back in hole open ended. BJ Services hooked up to the drill pipe and pumped a 73-sack class A Gas Block cement plug from 551 feet to 351 feet within the 9.625-inch diameter casing.
1537058368 2020-6-2 0:00:0 PB No Violations 3.00
1539382518 2019-7-11 0:00: PB No Violations 0.60
1546961802 2018-12-28 Plug / Plug Back No Violations On the day of my inspection, Brent Bear and I met with the landowner, Phil Dobeck, on-site and found gas bubbling within the 13 3/8 inch outside diameter casing. The square cellar was holding water that measured approximately 1 1/2 feet to 2 feet from the surface with no observed oil sheen. EQT Production Company has submitted a plan to the division to reopen to plug and abandon this well.
1547563983 2019-01-14 Plug / Plug Back No Violations On the day of my inspection the rig has not moved in to the location. I called Beau Fry of EQT on the status and asked for a key to the gate.
1554127505 2019-03-20 Plug / Plug Back No Violations The inspection revealed the Fountain Quail rig 8 (Schramm 250) was getting ready to run a combination of bottom hole assembly of smooth mills from Baker tool to a depth of 225 feet. The rig ran the tools in to clean up the 9 5/8- inch casing at 181 feet. Then the camera was running in the well from Keystone wireline services and showed the Baker tools can be set with out getting tore up. Baker tool set an easy drill cement retainer in the 9 5/8-inch casing at 195 feet.
1563808366 2019-7-22 0:00: PB No Violations 0.50
1564409478 2019-7-29 0:00: PB No Violations 0.60
1564409760 2019-7-29 0:00: PB No Violations 0.60
1567279695 2019-8-28 0:00: PB No Violations 0.30
1567603742 2018-07-27 Plug / Plug Back No Violations The purpose of my inspection was a status check on remediating the leaking plugged well. During my inspection the Fountain Qual Rig 8 drilled the 500 feet surface plug with an 8.75-inch diameter tri-cone bit. The rig circulated and cleaned the hole in preparation to run a down hole camera on 7/30/18.
1575030980 2019-11-21 0:00 PB No Violations 1.10
1575895885 2019-12-2 0:00: PB No Violations 1.00
1576005070 2019-12-10 0:00 PB No Violations 0.50
1583245016 2020-3-3 0:00:0 PB No Violations 0.50
1585523827 2020-3-11 0:00: PB No Violations 0.40
1590163537 2020-5-21 0:00: PB No Violations 6.00
1590499173 2020-5-22 0:00: PB No Violations 4.60
1590754965 2020-5-28 0:00: PB No Violations 4.50
1591016753 2020-5-9 0:00:0 PB No Violations 3.40
1591112583 2020-6-1 0:00:0 PB No Violations
1592932456 2020-6-22 0:00: PB No Violations 2.20
1593531475 2020-6-29 0:00: PB No Violations 2.00
1594204638 2020-7-6 0:00:0 PB No Violations 3.00
1596187029 2018-08-15 Plug / Plug Back No Violations
1600040444 2020-6-4 0:00:0 PB No Violations 8.10
1600639172 2020-6-8 0:00:0 PB No Violations 4.00
1601472709 2020-9-29 0:00: PB No Violations 9.30
1602086934 2020-10-6 0:00: PB No Violations 4.70
1603101080 2020-10-13 0:00 PB No Violations 3.60
1619380667 2020-1-2 0:00:0 PB No Violations 0.80
1626461242 2020-7-13 0:00: PB No Violations 10.70
1646885876 2019-8-21 0:00: PB No Violations 0.70
1724152022 2018-08-23 Plug / Plug Back No Violations KLX was on location to set a composite bridge plug within the 9.625 inch diameter casing at 551 feet. The tool was evaluated and prior to my departure ODNR Pat Shreve arrived on location to witness the tool being set.
1742076053 2019-7-15 0:00: PB No Violations 0.30
177170774 2020-6-15 0:00: PB No Violations 2.00
1782887963 2015-12-07 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed the well the well remains in Temporary Inactive status, and equipped with a Cactus casing wellhead with valves in the closed position with no flowline installed. Production equipment included a sand trap, a GP Unit, a sand purge tank, 8-400bbl tanks and 140bbl within containment and a gas combustor and will be shared with the 34059242800100 Dobeck 580015. The location was gated and grating was protecting the cellar with proper identification present at the entry and at the wellhead. The water impoundment was securely fenced in with a life preserver at the locked gate.
1844606017 2018-08-15 Plug / Plug Back No Violations The inspection today was a meeting with EQT. Brent Bear and I accompanied Austin Gutridge. We had met Rick Green and Beau Fry with EQT. The inspection revealed the well did not appear to be leaking. Fountain Quail Rig 8 was in the process of skidding to the well to plug. Plugging procedures were discussed between EQT and ODNR. ODNR is awaiting a plugging proposal from EQT.
1878244287 2019-7-23 0:00: PB No Violations 2.50
1940999795 2018-08-27 Plug / Plug Back No Violations The inspection was conducted as part of a re-plugging operations and due to Compliance Notice number -
1959168704 2020-8-18 0:00: PB No Violations 4.70
1989640701 2019-7-18 0:00: PB No Violations 1.10
1992001711 2019-6-17 0:00: PB No Violations 0.20
2034958497 2018-04-23 Plug / Plug Back No Violations During my inspection Energy Fishing and Rental were on location with their casing jacks. The casing jacks were rigged up and pulled 180,000 pounds to pull the 5.5 inch diameter casing out of the casing head. The casing head was disassembled and the backside of the 9.625 inch diameter intermediate casing had a small amount of gas that was bled down immediately. After bleeding down the gas it did not reappear. Conserv Incorporated pulled stretch on the casing while running within the 5.5 inch diameter casing with the wireline free point locator. The tool was calibrated and then was ran down to tag the prior cement plug top at 3500 feet. The tool verified a free point at 2,777 feet. The free point locater was tripped out of hole. Conserv tripped in hole with a casing cutter and cut the casing at 2751 feet.
2040943696 2020-8-28 0:00: PB No Violations 1.70
2042393132 2020-7-10 0:00: PB No Violations 2.30
207187660 2020-8-20 0:00: PB No Violations 2.00
2089626705 2013-12-11 Drill / Deepen / Reopen No Violations On the day of my inspection, I witnessed an Excavator solidifying the drill pits, the well has been drilled down 6968 (Black River) and is waiting for the drilling rig to arrive and complete the lateral bore (13,943) Point Pleasant, the I.D. is posted at the entry of the lease road.
2116842031 2019-04-12 Plug / Plug Back No Violations The inspection revealed that the rig and equipment was off the pad. Cactus night cap was bled off from the work on the pad and had broke off the line and gauge. The line was repaired, and the gauge was at 20 psi. The company had placed concrete barriers around the well and the cellar is dry.
2118031944 2018-03-28 Plug / Plug Back No Violations On the day of my inspection accompanied by ODNR Inspector Jeff Adams, we met with EQT Plugging Specialist Josh Williams and reviewed the work done yesterday witnessed by ODNR Inspector Justin Smith. Conserv Incorporated (CI) had removed the check valve, safely bled well down, set at cast iron bridge plug at 6249 feet and successfully performed a 1500 pound per square inch pressure test for 20 minutes. Conserv Incorporated Wireline Service (CIWS) was rigged up and performed a cement bond log (CBL) on the 5.5 inch diameter production casing.
2139091015 2020-7-27 0:00: PB No Violations 1.00
228131856 2019-3-21 0:00: PB No Violations 1.00
289319637 2017-3-22 0:00: DD No Violations 1.50
385049191 2020-6-11 0:00: PB No Violations 1.50
434030416 2019-12-19 0:00 PB No Violations 0.20
44052145 2020-10-23 0:00 PB No Violations 0.30
494358497 2019-5-13 0:00: PB No Violations 1.30
57832985 2019-11-21 0:00 PB No Violations 1.00
612321277 2019-5-17 0:00: PB No Violations 0.20
61584530 2020-6-10 0:00: PB No Violations 5.80
62103232 2018-3-26 0:00: DD No Violations 1.00
623219531 2018-8-2 0:00:0 PB No Violations 1.00
650235603 2019-12-2 0:00: PB No Violations 0.20
713495836 2019-4-1 0:00:0 PB No Violations 1.00
715523761 2020-7-20 0:00: PB No Violations 5.90
777980161 2018-7-31 0:00: PB No Violations 4.00
803965431 2015-4-22 0:00: DD No Violations 2.00
863309937 2018-8-22 0:00: PB No Violations 6.50
881274820 2019-3-15 0:00: PB No Violations 3.20
90835173 2020-6-24 0:00: PB No Violations 0.70
96197826 2020-7-2 0:00:0 PB No Violations 8.10

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0650839104 US-OH-127375 2018-06-13 9-9-04(D) Uncontrolled flow of oil or gas from a well
0650839104 US-OH-127376 2018-06-13 NONE3 Defective casing, leaking well

For data sources see[3]