34-059-24310

Well Details

Well ID: 34-059-24310
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Spencer Township
Operator Name: EQT PRODUCTION COMPANY
Well Pad ID: US-OH-000721
Farm/Lease Name: NCD3
License Status: Not Drilled
License Date: 2013-10-21
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Horizontal
Latitude: 39.920000
Longitude: -81.620000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-08-23 Proposed Formations:BLACK RIVER, Issued Date:8/23/2013, Expired Date:8/23/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2013-10-21 Proposed Formations:POINT PLEASANT, Issued Date:10/21/2013, Expired Date:10/21/2015 12:00:00 PM, Drilling unit acres:124.78, Proposed Well Type:OG, Proposed Well Class:POOL
Construction Permit Expires 2015-10-21
Record Last Modified 2018-11-01

For data sources see[2]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 EQT PRODUCTION COMPANY Brine 12402 104
2015 EQT PRODUCTION COMPANY Brine 6840 361
2016 EQT PRODUCTION COMPANY Brine 2561 272
2017 PIN OAK ENERGY PARTNERS LLC Brine 1015 265
2018 PIN OAK ENERGY PARTNERS LLC Brine 1173 360
2019 PIN OAK ENERGY PARTNERS LLC Brine 104 90

For data sources see[3] [4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1260177222 2019-11-21 0:00 PW No Violations 0.30
-1286548114 2018-8-15 0:00: PW No Violations 0.50
-1307066001 2019-3-12 0:00: PW No Violations 0.90
-1398255467 2019-1-29 0:00: PW No Violations 0.20
-1399009179 2018-3-29 0:00: PW No Violations 0.50
-1627190719 2015-12-7 0:00: PW No Violations 0.50
-17895179 2018-3-29 0:00: PW No Violations 0.50
-2098265170 2018-8-20 0:00: PW No Violations 0.50
-210820811 2018-8-15 0:00: PW No Violations 0.40
-30807304 2018-8-15 0:00: ND No Violations 0.10
-532430560 2020-3-5 0:00:0 PW No Violations 0.50
-658112004 2020-3-5 0:00:0 PW No Violations 0.20
-903650741 2014-9-15 0:00: PL No Violations 0.50
-931789033 2019-2-6 0:00:0 PW No Violations 0.40
0017895179 2018-03-29 Production Wells No Violations On the day of my inspection I accompanied ODNR Inspector Jeff Adams please see his report for details.
0030807304 2018-08-15 Not Drilled No Violations The purpose of my inspection today was a status check. During my inspection there was no evidence of the well being drilled and the permit expired in the year 2015. Three production wells were located on pad under the permit numbers 34059242760100, 34059242740100, and 34059243100100.
0210820811 2018-08-15 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the wells were equipped with a production tree style wellhead and were equipped to produce with an enhanced recovery method by injecting produced gas into the 5.5-inch diameter production casing. The well appeared to be producing. The production equipment consisted three sand traps, three gas production units, twelve 400-barrel tanks, a sand purge tank, one 200-barrel tank, one combustor, and three compressors. Identification was at the well entry, the wellhead, and tank battery. Production records were current. Accompanied by ONDR inspector Pat Shreve and ODNR Regional Supervisor Brent Bear.
0282740615 2019-02-05 Production Wells No Violations The inspection is just on well head only. Luke Mallet accompanied me on the inspection and revealed the third compressor feeds the this well PN-4310. The well is compressing gas down casing and feeding oil and gas back into the tubing. The gauge on the well head is unreadable and will pump out the cellar tomorrow. The red valves are safety valve shut offs and hold true on the Gas Production Units.
0407017140 2016-04-27 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a sand trap, a GP Unit, a combustor, a sand purge tank, 12-400bbl tanks and 140bbl tank shared with the 34059242740100 NCD3 580011 and 34059242760100 NCD3 580010 within containment. The well was equipped with a production tree producing by gas injection and was online at the time of inspection. The impoundment has been closed and restored to grade with seed and mulch in place.
0449775819 2019-02-13 Production Wells No Violations
0542091007 2017-06-23 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a sand trap, a GP Unit, a combustor, a sand purge tank, 3-compressor units, 12-400 barrel tanks and a 140 barrel tank shared with the 34059242740100 NCD3 580011 and 3405924276010 NCD3 580010 within containment. The well was equipped with a production tree producing by gas injection and was online at the time of inspection. Identification was present and production records were current.
0634105999 2014-08-12 Preliminary Restoration No Violations On the day of my inspection the site passed preliminary restoration according ORC 1509.072A.
0903650741 2014-09-15 Preliminary Restoration No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A.
0931789033 2019-02-06 Production Wells No Violations The inspection revealed that Pin Oak (Luke Mallet) was pumping out the cellar and that the pressure gauge being monitored on the 9 5/8 casing on the 2-inch port which had 2 psi is on the pressure gauge.
1005750960 2019-5-2 0:00:0 PW No Violations 0.20
1045838042 2016-12-16 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a sand trap, a GP Unit, a combustor, a sand purge tank, 3-compressor units, 12-400 barrel tanks and a 140 barrel tank shared with the 34059242740100 NCD3 580011 and 3405924276010 NCD3 580010 within containment. The well was equipped with a production tree producing by gas injection and was online at the time of inspection.
1067631227 2018-09-05 Production Wells No Violations The purpose of my inspection was a status check. I was contacted by Pin Oak well tender Luke Mallet. Mr. Mallet stated that he has installed gauges for annular pressure monitoring. During my inspection the wells were equipped with a production tree style wellhead and were equipped to produce with an enhanced recovery method by injecting produced gas into the 5.5-inch diameter production casing. Production valves were in the open position. Annular pressure monitoring was now present. The production equipment consisted three sand traps, three gas production units, twelve 400-barrel tanks, a sand purge tank, one 200-barrel tank, one combustor, and three compressors. Identification was at the well entry, the wellhead, and tank battery. Production records were current.
1286548114 2018-08-15 Production Wells No Violations Brent Bear and I accompanied Austin Gutridge on the inspection. The inspection revealed the well is equipped with a large flange style well head with 2 master tubing valves and 1 flowline valve. The well is an enhanced gas system by compressing gas down tubing annulus and produce the oil thru the tubing. The tank site consists of [12] 400-barrel steel tanks, [1] 40-barrel steel tank enclosed within a Galvanized and rubber impoundment. There is a gas production unit and a gas cyclone. The compressors are over by the entrance of the pad.
1307066001 2019-03-12 Production Wells No Violations The inspection revealed the well is equipped with a Cactus flanged well head assembly. The 2--inch casing. No riser was installed because the pressure is at 0 psi.
1398255467 2019-01-29 Production Wells No Violations

[1] Gas production unit, [1] sand trap, [12] 400-barrel steel tanks, [1]140-barrel steel tank, cyclone combustor and a compressor. The two outside compressors were running and the center one was not.

1399009179 2018-03-29 Production Wells No Violations On the day of my inspection accompanied by ODNR Inspector Doug Bennett, I witnessed the production equipment included a sand trap and GP Unit. A combustor, a sand purge tank, 12- 400 barrel tanks and 140 barrel tank shared with the 34059242740100 NCD3 580011 and 3405924276010 NCD3 580010 within containment. The well was equipped with a production tree producing by gas injection and was online at the time of inspection. Proper identification was present and production report was up to date.
1622310803 2014-03-12 Drill / Deepen / Reopen No Violations On the day of my site inspection, there are no spills to report, erosion control has been established around the pad / top soil stock pile and entry way, the perimeter drainage and catch basins are working properly, all rain water is contained on the pad, Halliburton preformed a squeeze job at a depth of 5826 to prevent fluid lose, the Pioneer Rig #70 was not drilling at the time of my inspection.
1624941831 2014-09-15 Preliminary Restoration No Violations On the day of my inspection I witnessed that EQT was preparing for flow back on Wednesday and the site passed preliminary restoration according to ORC 1509.072A.
1627190719 2015-12-07 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a sand trap, a GP Unit, a combustor, a sand purge tank, 12-400bbl tanks and 140bbl tank shared with the 34059242740100 NCD3 580011 and 3405924276010 NCD3 580010 within containment. The well was equipped with a production tree producing by gas injection and was online at the time of inspection.
1745684556 2018-08-20 Production Wells No Violations The purpose of my inspection today was a status check. On 8/15/18 I met in person with Luke Mallet the well tender for Pinn Oak. I explained to Mr. Mallett that gauges will need installed to properly monitor annular pressures. Mr. Mallett was unsure of the current annular pressures for each well and he stated he will have the work completed in two weeks. During my inspection today, the gauges have not yet been installed. A follow up inspection will be conducted.
2098265170 2018-08-20 Production Wells No Violations The inspection was conducted under an enhanced production set-up. The well is equipped with a tree style well head and all valves are open. The production equipment consists of one Gas Production Unit, [12] 400-barrel steel tanks enclosed within a galvanized impoundment. The gas vapors are sent thru a gas Cyclone and burned. There is a compressor to compress gas and send the gas back down the tubing annulus.
282740615 2019-2-5 0:00:0 PW No Violations 1.00
407017140 2016-4-27 0:00: PW No Violations 0.50
449775819 2019-2-13 0:00: PW No Violations 0.20
542091007 2017-6-23 0:00: PW No Violations 0.50
634105999 2014-8-12 0:00: PL No Violations 0.80

For data sources see[5]

References