34-099-22851

Well Details

Well ID: 34-099-22851
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: UKRAINIAN ORTHODOX CHURCH
License Status: Producing
License Date: 2000-01-06
Spud Date: 2000-03-06
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2000-03-08
Well Total Depth: 3473.00 ft
Configuration: Vertical
Latitude: 41.110000
Longitude: -80.680000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2000-01-06 Proposed Formations:BASS ISLAND DOLOMITE, Issued Date:1/6/00, Expired Date:1/5/01 6:00:00 AM, Drilling unit acres:41.257, Proposed Well Type:OG, Proposed Well Class:ESPW
Original Spud 2000-03-06 RBDMS Rec
Completed 2000-03-08 RBDMS Rec
Reached Total Depth 2000-03-08 RBDMS Rec
Completion Report Received 2000-08-22 RBDMS Rec
Construction Permit Expires 2001-01-05 RBDMS Rec
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-11-17 3385 3389 20
3385 3389 20
3385 3389 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 2000 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
0 0 0
2002 BOCOR HOLDINGS, LLC 0.00 0.00 0
2003 BOCOR HOLDINGS, LLC 0.00 0.00 0
2004 BOCOR HOLDINGS, LLC 0.00 0.00 0
2007 BOCOR HOLDINGS, LLC 0.00 0.00 0
2012 BOCOR HOLDINGS, LLC 0.00 0.00 0
2013 BOCOR HOLDINGS, LLC 0.00 0.00 0
2014 BOCOR HOLDINGS, LLC 0.00 0.00 0
2015 BOCOR HOLDINGS, LLC 913.00 59.00 369
2016 BOCOR HOLDINGS, LLC 1008.00 30.00 365
2017 BOCOR HOLDINGS, LLC 917.00 35.00 365
2018 BOCOR HOLDINGS, LLC 968.00 10.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2002 BOCOR HOLDINGS, LLC Brine 0 0
2003 BOCOR HOLDINGS, LLC Brine 0 0
2004 BOCOR HOLDINGS, LLC Brine 0 0
2007 BOCOR HOLDINGS, LLC Brine 0 0
2012 BOCOR HOLDINGS, LLC Brine 0 0
2013 BOCOR HOLDINGS, LLC Brine 0 0
2014 BOCOR HOLDINGS, LLC Brine 0 0
2015 BOCOR HOLDINGS, LLC Brine 21 369
2016 BOCOR HOLDINGS, LLC Brine 0 365
2017 BOCOR HOLDINGS, LLC Brine 0 365
2018 BOCOR HOLDINGS, LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1821872637 2010-4-15 0:00: PW No Violations
0173819067 2018-06-21 Production Wells No Violations The purpose of my inspection was to document the status of identification at well #2-2851. At the time of inspection correct identification was posted at the well head. No further action is necessary.
0785093327 2004-04-08 Production Wells No Violations The tank battery is shared with permit 2807 and consists of 1-210 bbl storage tank, 1-50 bbl salt water tank, 1-separator and a dike that is low. This well is being used for domestic only.
1701602905 2018-05-31 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-2851. RBDMS indicated reported production was current. Access to the well and tank battery remained drivable and stable. The well was enclosed within a locked chain-link fence enclosure hidden with landscape. Identification was present but illegible. The 8.625 well head was above grade and closed to atmosphere. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the closed position. No leaks were observed. Staining consistent with a legacy operation was present. A domestic supply connection was present. The tank battery was shared with #2-2807. A worn earthen dike that was free of fluid was present around the equipment. A chain-link fence enclosure was present on top of the dike. Equipment on location consisted of one (1) horizontal separator and one (1) 50 bbl production tank. The separator remained in good repair and contained a current 16 day chart. The production tank remained in good repair and contained an identification sign that was peeling from the tank. The tank valve was closed, but missing a plug. I will contact the operator to make corrections to the identification and install a plug in the valve.
173819067 2018-6-21 0:00: PW No Violations 0.20
1821872637 2010-04-15 Production Wells No Violations I performed a random field inspection. I GPSd both the tank battery and the wellhead. I continued to walk around both the wellhead and the tank battery and found both to be in good condition. The ID signs were posted. There were no violations at this time.
785093327 2004-4-8 0:00:0 PW No Violations 0.50
iDIAN00458 2000-06-27 Preliminary Restoration No Violations
iDIAN004582 2000-6-27 0:00: PL No Violations

For data sources see[9]

References