X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-23130

Well Details

Well ID: 34-099-23130
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Boardman Township
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: KUSHMA
License Status: Producing
License Date: 2010-06-29
Spud Date: 2010-11-03
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2010-11-08
Well Total Depth: 5645.00 ft
Configuration: Vertical
Latitude: 41.050000
Longitude: -80.660000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-06-29 Proposed Formations:OHIO SHALE THRU MEDINA, Issued Date:6/29/2010, Expired Date:6/29/2011 6:00:00 AM, Drilling unit acres:41.13, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-11-08
Completion Report Received 2011-01-21
Construction Permit Expires 2011-06-29
Correction to Well 2012-09-07 UNIT SIZE CHANGED TO 64.72 ACRES.
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-05-09 5380 5434 66
5380 5434 66
5380 5434 66

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-11-30 H2O 15 114000 Gal 80000 Producers Service Corporation

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 OHIO VALLEY ENERGY SYSTEMS COR 21266.00 95.00 225
2012 OHIO VALLEY ENERGY SYSTEMS COR 18714.00 51.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 13632.00 59.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 9918.00 55.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 8806.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 7568.00 0.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 6683.00 61.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 6037.00 37.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 445 225
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 108 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 54 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 87 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 37 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1070722974 2010-12-25 0:00 UL No Violations
-1279076236 2011-3-2 0:00:0 UL No Violations
-1343819087 2010-11-8 0:00: DD No Violations
-1448475915 2011-1-28 0:00: UL No Violations
-1950047551 2010-11-3 0:00: DD No Violations
-221247371 2017-12-13 0:00 PW No Violations 0.60
-64778491 2011-8-4 0:00:0 PL No Violations
-736247352 2011-4-7 0:00:0 UL No Violations
-93174478 2010-11-4 0:00: DD No Violations
0046568766 2010-11-18 UrbanPreliminary Restoration No Violations The drilling pits are closed. There were no violations at this time.
0064778491 2011-08-04 Preliminary Restoration No Violations Board on board fencing installed around well head and tank battery. ID sign posted. Top soil graded out. Vegetation established. Landscaping done around well head and tank battery. All drilling equipment removed from site. This well site satisfies ORC 1509.072. Preliminary restoration passed. No violations at this time.
0093174478 2010-11-04 Drill / Deepen / Reopen No Violations I performed a rig inspection on Wildcat rig #1. The drillling crew were running into the hole with 8 5/8 casing. The drilling depth was 687. This inspection satisfies 1501:9-9-03. There were no violations at this time.
0221247371 2017-12-13 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-3130. Inspector John Fleming was present during the inspection. A review of RBDMS indicated production reporting was current. Access to the well was through a commercial parking lot. The well head and tank battery were enclosed by a locked chain-link fence enclosure obscured with landscaping. Correct identification was present. The 8.625 well head was at grade. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. A domestic supply connection was present. Production equipment was within a locked board fence enclosure obscured by landscaping. Correct identification was present. A stable earthen dike that was free of fluid was present around the equipment. Equipment within the dike consisted of one (1) horizontal separator, one (1) 70 bbl production tank and one (1) 50 bbl brine tank. The separator remained in good repair and contained a current 7 day production chart. The production tank remained in good repair. Valves were closed and plugged. A tank float safety shut off device was connected to the separator. A charcoal canister and spark arrestor were present. The poly brine tank remained in good repair. The inlet valve was closed. The drain valve was closed and plugged. No violations were observed during this inspection.
0266161854 2011-07-05 UrbanPreliminary Restoration No Violations The were trees and bushes planted around the tank battery and the wellhead. There was vegetation growth on the location with an ID sign on both the wellhead and the tank battery. This well PASSES PRELIMINARY RESTORATION.
0736247352 2011-04-07 UrbanPreliminary Restoration No Violations The location is in a rough grade. The board on board fences are around the wellhead and the tank battery. The ID signs are posted. The drilling location is muddy.
1070722974 2010-12-25 UrbanPreliminary Restoration No Violations The drilling location top soil has been spread. It is in a rough grade mode. A water tank from the frac is still on the location.
1279076236 2011-03-02 UrbanPreliminary Restoration No Violations The board on board fence was around the tank battery and the wellhead with an ID sign posted. There were no violations at this time.
1288872341 2010-11-04 Drill / Deepen / Reopen No Violations I witnessed the running and the cementing of the 8 5/8 casing on Wildcat rig #1. There were no violations at this time.
1289329520 2010-11-08 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 4 1/2 casing. There were no violations at this time.
1289388599 2010-11-09 UrbanPreliminary Restoration No Violations The drilling rig is gone. The steel fence is around the drilling pits. There were no violations at this time.
1343819087 2010-11-08 Drill / Deepen / Reopen No Violations I performed a rig inspection on Wildcat rig #1. The crew were no the process of running into the hole with 4 1/2 casing. This inspection satisfies 1501:9-9-03. There were no violations at this time.
1448475915 2011-01-28 UrbanPreliminary Restoration No Violations The tank battery was installed. Still location in rough grade. I called Ted Hill(330-719-0100) for status on the completion. Ohio Valley are waiting to bore a hole to the house for gas. Then they will proceed on getting the rough grade to a better finished grade. There were no violations at this time.
1510508857 2010-11-15 UrbanPreliminary Restoration No Violations The rig is gone and the debris hauled off. The drilling pits fluid has been emptied. The pits are not closed yet.
1776227107 2011-06-09 UrbanPreliminary Restoration No Violations The drilling area was seeded and strawed. The area was landscaped. No vegetation growth. There were no violations at this time.
1950047551 2010-11-03 Drill / Deepen / Reopen No Violations I perform a rig inspection on Wildcat rig 1. The drilling depth was 39 and on fluid. The ID sign was posted. This inspection satisfies 1501:9-9-03. There were no violations at this time.
2118708573 2010-11-30 UrbanPreliminary Restoration No Violations The pits are closed. The logging truck is on location. Appalachian Well Service. The frac will be on 12/1/10. There were no violations at this time.
266161854 2011-7-5 0:00:0 UL No Violations
46568766 2010-11-18 0:00 UL No Violations

For data sources see[9]

References