X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-103-21508

Well Details

Well ID: 34-103-21508
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: MFC DRILLING INC
Well Pad ID:
Farm/Lease Name: BOBIER
License Status: Plugged and Abandoned
License Date: 2017-04-21
Spud Date: 1965-04-28
Spud Drilling Contractor:
Final Drill Date: 1965-05-28
Well Total Depth: 3297.00 ft
Configuration: Vertical
Latitude: 41.020000
Longitude: -81.920000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1965-04-28
Completed 1965-05-28
Reached Total Depth 1965-05-28
Change of Owner 2002-09-06 Operator changed from 255, KING DRILLING CO to 3059, MFC DRILLING INC
APP 2017-04-21 Proposed Formations:CLINTON, Issued Date:4/21/2017, Expired Date:4/21/2019 12:00:00 PM, Drilling unit acres:121.5, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2017-08-22
Record Last Modified 2018-07-11
Construction Permit Expires 2019-04-21

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3212 3222 2
2006-09-11 3224 3332 16
3212 3222 2
3212 3222 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 900 Bbl 28000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 KING DRILLING CO 155.00 17.00 0
1986 KING DRILLING CO 1.00 20.00 365
1995 KING DRILLING CO 0.00 8.00 365
1996 KING DRILLING CO 0.00 16.00 365
1997 KING DRILLING CO 0.00 0.00 365
1998 KING DRILLING CO 0.00 19.00 365
1999 KING DRILLING CO 0.00 9.00 365
2000 KING DRILLING CO 0.00 7.00 365
2001 KING DRILLING CO 0.00 13.00 365
2002 MFC DRILLING INC 0.00 0.00 365
2003 KING DRILLING CO 0.00 0.00 365
2004 KING DRILLING CO 0.00 0.00 365
2005 KING DRILLING CO 0.00 0.00 365
2006 MFC DRILLING INC 5559.00 100.00 365
2007 MFC DRILLING INC 2750.00 79.00 365
2008 MFC DRILLING INC 2244.00 77.00 365
2009 MFC DRILLING INC 1983.00 39.00 365
2010 MFC DRILLING INC 1681.00 38.00 365
2011 MFC DRILLING INC 1095.00 38.00 365
2012 MFC DRILLING INC 1078.00 0.00 366
2013 MFC DRILLING INC 1047.00 39.00 365
2014 MFC DRILLING INC 711.00 0.00 365
2015 MFC DRILLING INC 424.00 37.00 365
2016 MFC DRILLING INC 438.00 40.00 365
2017 MFC DRILLING INC 316.00 38.00 212

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 KING DRILLING CO Brine 0 0
1986 KING DRILLING CO Brine 0 365
1995 KING DRILLING CO Brine 0 365
1996 KING DRILLING CO Brine 0 365
1997 KING DRILLING CO Brine 0 365
1998 KING DRILLING CO Brine 0 365
1999 KING DRILLING CO Brine 0 365
2000 KING DRILLING CO Brine 0 365
2001 KING DRILLING CO Brine 0 365
2002 KING DRILLING CO Brine 0 365
2003 KING DRILLING CO Brine 0 365
2004 KING DRILLING CO Brine 0 365
2005 KING DRILLING CO Brine 0 365
2006 MFC DRILLING INC Brine 15 365
2007 MFC DRILLING INC Brine 0 365
2008 MFC DRILLING INC Brine 0 365
2009 MFC DRILLING INC Brine 12 365
2010 MFC DRILLING INC Brine 0 365
2011 MFC DRILLING INC Brine 0 365
2012 MFC DRILLING INC Brine 0 366
2013 MFC DRILLING INC Brine 0 365
2014 MFC DRILLING INC Brine 0 365
2015 MFC DRILLING INC Brine 10 365
2016 MFC DRILLING INC Brine 0 365
2017 MFC DRILLING INC Brine 0 212

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1728176598 2014-5-5 0:00:0 PW No Violations
1728176598 2014-05-05 Production Wells No Violations Inspected production well on 05/05/2014. The tank battery consists of 1-100 bbl steel tank, 1-1,600 gal plastic tank, horizontal separator, and a compressor station within an earthen dike. The diked area is located within an unlocked metal fence. The tank battery is used by multiple wells; identification is posted for all wells utilizing it. The well is equipped with a pump jack with an electric motor located within an unlocked metal fence. Well identification is posted at the wellhead. No problems were noted at the time of the inspection.

For data sources see[9]

References