34-153-21669

Well Details

Well ID: 34-153-21669
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: QUIST DONALD E
Well Pad ID:
Farm/Lease Name: QUIST UNIT
License Status: Domestic Well
License Date: 1984-07-27
Spud Date: 1984-08-09
Spud Drilling Contractor: ARMSTRONG DRLG
Final Drill Date: 1984-08-17
Well Total Depth: 3840.00 ft
Configuration: Vertical
Latitude: 41.270000
Longitude: -81.470000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-01-03 635 AMERICAN WAY PROD INC GeoDate 1/3/84
Oil and Gas 1984-01-03 Issued Date 12/30/83 Expired Date 6/27/84 Acres 0020280 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1984-02-03 635 AMERICAN WAY PROD INC GeoDate 2/3/84
Oil and Gas 1984-02-03 Issued Date 12/30/83 Expired Date 6/27/84 Acres 0020280 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1984-07-27 568 STONEWALL GAS CO GeoDate 7/27/84
Oil and Gas 1984-07-27 Issued Date 7/27/84 Expired Date 1/23/85 Acres 0020280 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03840 Proposed Drill Depth 03840
Original Spud 1984-08-11 R.L. 2-4-84, R.I. 7-28-84
Completed 1984-08-17 R.L. 2-4-84, R.I. 7-28-84
Reached Total Depth 1984-08-17 R.L. 2-4-84, R.I. 7-28-84
Construction Permit Expires 1985-01-23 R.L. 2-4-84, R.I. 7-28-84
Completion Report Received 1985-10-22 R.L. 2-4-84, R.I. 7-28-84
CO 1993-01-25 28 CGAS EXPLORATION,INC GeoDate 7/27/84
CO 1993-06-15 4570 QUIST DONALD E GeoDate 7/27/84
Record Last Modified 2017-02-15 R.L. 2-4-84, R.I. 7-28-84

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3706 3746 22
3706 3746 22
3706 3746 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 0 0
H2O 0 2400 Bbl 40000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 STONEWALL GAS CO 5762.00 77.00 365
1993 CGAS EXPLORATION 475.00 0.00 366

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 STONEWALL GAS CO Brine 0 365
1993 CGAS EXPLORATION Brine 0 366

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1533743408 2018-08-02 Production Wells No Violations The Uniontown office received a request for inspection of the Packer # 1 well located at 2890 Farnham Road, Richfield, OH, 44286. The request was made by Lacy Androne ( 419.516.6543 ). I spoke with Ms. Androne, who indicated that the drinking water was unbearable to consume. A water treatment company supplied test results ( according to Androne ) which showed Total Dissolved Solids (TDS) above 3000 mg/L . Access to the well and tank battery was gained on a residential graveled driveway. The well was operated as an electric pumping well. The well was surrounded with a locked chain link fence. An inspection of the wellhead area did not indicate any leaking pipes or fittings. The stuffing box had grease caked on it from lubricating the polish rod. The valve to the 8.625 X 4.5 annular space was covered and not visible during this inspection. The wellhead was approximately 225 to the residential water well, which was located on the west side of the house. The tank battery (~ 300 from water well) was locked and surrounded with a chain link fence. The I. D. signage was posted and legible. There were two (2) 100 barrel stock tanks and a 2408 horizontal separator in the tank battery. The load line was plugged with a flat plug.. My research indicated that the original tankage capacity, for the Packer #1, was reported to be 310 barrels. This volume of capacity was reduced in 2014 to 200 barrels. The tanks were visually inspection and I did not detect any integrity issues. I did not identify any areas of vegetation which had been scalded or voided of vegetation. Using historical aerial photos it appears that the drilling pits were located on the north side of the well toward the Turnpike. I did not find any surface expression of contamination which would impact the water. I referred Ms. Androne to Scott Scheiner ( Environmental Assessment Program ) for further investigation.
1534338706 2018-08-15 UrbanProduction Wells Violations Noted The Quist # 1 was designated as a Domestic well. The access was gain at 8312 Valley View Road, Macedonia, OH 44056 through the residence driveway. The wellhead was secured with a fence and was unlocked at my request to secure access for the inspection. The vegetation was trimmed and maintained. The well was operated as a plunger lift well with 1.5 tubing inside of 4.5 production casing. The 8.625 surface casing ( from records ) was not visible at the surface. The domestic gas connection point was made at the 4.5 production casing with a regulator, pop - off valve and gauge. The valves were closed on the domestic connection. The gate valve on the 1.5 tubing was closed as was a two (2) inch valve on the flow line. The wellhead was equipped with a motor valve and intermitter control box ( batteries were dead ). There was not any of the required identification signage per OAC 1501:09-9-05 ( E ) 1. I did not identify any leaks or contamination during this inspection at the wellhead. The tank battery was located approximately 100 west of the wellhead. The tank battery was surrounded with a locked ( I requested removal for access ) chain link fence topped with barbed wire. A earthen dike surrounded the tank battery. The vegetation was maintained and cut. The tank battery was comprised of one (1) 140 barrel stock tank, one (1) buried concrete brine vault and one (1) 2408 horizontal separator with orifice meter. A choke manifold, on the inlet side of the separator, was closed. The two (2) inch valve leading from the meter run to sales line was closed. The three (3) inch oil load line , on the stock tank, was locked and plugged, but the two (2) inch brine drain did not have a lock. The brine tank was full. I did not identify any leaks or contamination in the tank battery. The required Urbanized Area ( OAC 1501:9-9-05 ( E ) 1 ) signage was not posted. The Owner shall post identifying identification signage that is compliant with OAC 1501:9-9-05 ( E ) 1 on both the wellhead an

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1534338706 US-OH-114757 2018-08-16 ID (a-i)

For data sources see[9]

References