34-153-22623

Well Details

Well ID: 34-153-22623
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: TRANSIT ENERGY INC
Well Pad ID:
Farm/Lease Name: BREITENSTINE-GENIS
License Status: Producing
License Date: 1990-01-02
Spud Date: 1990-03-16
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 1990-03-24
Well Total Depth: 3965.00 ft
Configuration: Vertical
Latitude: 40.980000
Longitude: -81.640000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1990-01-02 2771 TRANSIT ENERGY INC GeoDate 1/2/90
Oil and Gas 1990-01-02 Issued Date 12/29/89 Expired Date 12/29/90 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03965 Proposed Drill Depth 03965
Original Spud 1990-03-17
Completed 1990-03-24
Reached Total Depth 1990-03-24
Construction Permit Expires 1990-12-29
Completion Report Received 1991-04-29
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3828 3920 0
3828 3920 0
2006-09-11 3844 3916 17
3844 3916 17
3828 3920 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 20000 FRAC:WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1990 TRANSIT ENERGY INC 4289.00 0.00 96
1991 TRANSIT ENERGY INC 60149.00 0.00 365
1992 TRANSIT ENERGY INC 3605.00 0.00 365
1994 TRANSIT ENERGY INC 1732.00 0.00 365
1995 TRANSIT ENERGY INC 1579.00 0.00 365
1996 TRANSIT ENERGY INC 1515.00 0.00 365
1997 TRANSIT ENERGY INC 1026.00 0.00 365
1998 TRANSIT ENERGY INC 1096.00 0.00 365
1999 TRANSIT ENERGY INC 1026.00 0.00 365
2000 TRANSIT ENERGY INC 569.00 0.00 365
2001 TRANSIT ENERGY INC 574.00 0.00 365
2002 TRANSIT ENERGY INC 801.00 0.00 365
2003 TRANSIT ENERGY INC 1464.00 0.00 365
2004 TRANSIT ENERGY INC 1273.00 8.00 365
2005 TRANSIT ENERGY INC 1311.00 0.00 365
2006 TRANSIT ENERGY INC 1212.00 0.00 365
2007 TRANSIT ENERGY INC 615.00 0.00 365
2008 TRANSIT ENERGY INC 826.00 0.00 365
2009 TRANSIT ENERGY INC 1515.00 0.00 365
2010 TRANSIT ENERGY INC 853.00 0.00 365
2011 TRANSIT ENERGY INC 604.00 0.00 365
2012 TRANSIT ENERGY INC 641.00 0.00 366
2013 TRANSIT ENERGY INC 537.00 0.00 365
2014 TRANSIT ENERGY INC 650.00 0.00 365
2015 TRANSIT ENERGY INC 632.00 0.00 365
2016 TRANSIT ENERGY INC 464.00 0.00 272
2017 TRANSIT ENERGY INC 865.00 0.00 365
2018 TRANSIT ENERGY INC 867.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1990 TRANSIT ENERGY INC Brine 145 96
1991 TRANSIT ENERGY INC Brine 13 365
1992 TRANSIT ENERGY INC Brine 27 365
1994 TRANSIT ENERGY INC Brine 0 365
1995 TRANSIT ENERGY INC Brine 40 365
1996 TRANSIT ENERGY INC Brine 0 365
1997 TRANSIT ENERGY INC Brine 28 365
1998 TRANSIT ENERGY INC Brine 0 365
1999 TRANSIT ENERGY INC Brine 0 365
2000 TRANSIT ENERGY INC Brine 40 365
2001 TRANSIT ENERGY INC Brine 73 365
2002 TRANSIT ENERGY INC Brine 18 365
2003 TRANSIT ENERGY INC Brine 22 365
2004 TRANSIT ENERGY INC Brine 20 365
2005 TRANSIT ENERGY INC Brine 0 365
2006 TRANSIT ENERGY INC Brine 30 365
2007 TRANSIT ENERGY INC Brine 0 365
2008 TRANSIT ENERGY INC Brine 40 365
2009 TRANSIT ENERGY INC Brine 0 365
2010 TRANSIT ENERGY INC Brine 69 365
2011 TRANSIT ENERGY INC Brine 6 365
2012 TRANSIT ENERGY INC Brine 0 366
2013 TRANSIT ENERGY INC Brine 0 365
2014 TRANSIT ENERGY INC Brine 0 365
2015 TRANSIT ENERGY INC Brine 90 365
2016 TRANSIT ENERGY INC Brine 0 272
2017 TRANSIT ENERGY INC Brine 0 365
2018 TRANSIT ENERGY INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-665611178 2018-7-9 0:00:0 PW No Violations 0.50
-698831423 2005-9-2 0:00:0 PW No Violations
0000PL4151 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0665611178 2018-07-09 Production Wells No Violations I did a partial status check inspection for this well. The tank battery consists of a steel production tank, a vertical separator and a meter. The well is legibly identified at the tank battery. There are no compliance issues at the tank battery.
0698831423 2005-09-02 Production Wells Violations Noted Status check inspection - the tank battery did not have the required identification and the heater tube on the stock tank is starting to leak. Post the required ID and fix the tank leak.
0881087500 2007-08-09 Production Wells Violations Noted CASE 05-032 The violations have been corrected.
881087500 2007-8-9 0:00:0 PW No Violations
PL4151 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0698831423 US-OH-127907 2005-09-07 Well operation causing pollution and contamination
0698831423 US-OH-127908 2005-09-07 Failure to legibly identify well
0881087500 US-OH-130026 2005-09-07 Well operation causing pollution and contamination
0881087500 US-OH-130027 2005-09-07 Failure to legibly identify well

For data sources see[9]

References