X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-153-23003

Well Details

Well ID: 34-153-23003
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: EOS ENERGY LLC
Well Pad ID:
Farm/Lease Name: KIRK H & G UNIT
License Status: Producing
License Date: 2007-05-18
Spud Date: 2007-08-07
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2007-08-12
Well Total Depth: 3906.00 ft
Configuration: Vertical
Latitude: 41.140000
Longitude: -81.520000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-05-18 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:5/18/2007, Expired Date:5/17/2008 6:00:00 AM, Drilling unit acres:20.06, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-08-12
Reached Total Depth 2007-08-12
Correction to Well 2007-11-30 UNIT SIZE INCREASED TO 20.077 ACRES.
Completion Report Received 2008-01-09
Construction Permit Expires 2008-05-17
Change of Owner 2018-07-31 Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC
Record Last Modified 2018-07-31

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-03-10 3672 3744 40
3672 3744 40
3672 3744 40

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 7 200 Mscf 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 CUTTER OIL COMPANY 464.00 0.00 76
2008 CUTTER OIL COMPANY 11928.00 1301.00 365
2009 CUTTER OIL COMPANY 7549.00 539.00 365
2010 CUTTER OIL COMPANY 5987.00 404.00 365
2011 CUTTER OIL COMPANY 5193.00 446.00 365
2012 CUTTER OIL COMPANY 4221.00 351.00 362
2013 CUTTER OIL COMPANY 2302.00 35.00 365
2014 CUTTER OIL COMPANY 2553.00 335.00 365
2015 CUTTER OIL COMPANY 3088.00 214.00 365
2016 CUTTER OIL COMPANY 2487.00 212.00 365
2017 CUTTER OIL COMPANY 2405.00 360.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 CUTTER OIL COMPANY Brine 1637 76
2008 CUTTER OIL COMPANY Brine 599 365
2009 CUTTER OIL COMPANY Brine 301 365
2010 CUTTER OIL COMPANY Brine 397 365
2011 CUTTER OIL COMPANY Brine 322 365
2012 CUTTER OIL COMPANY Brine 160 362
2013 CUTTER OIL COMPANY Brine 10 365
2014 CUTTER OIL COMPANY Brine 340 365
2015 CUTTER OIL COMPANY Brine 267 365
2016 CUTTER OIL COMPANY Brine 142 365
2017 CUTTER OIL COMPANY Brine 219 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1583521067 2007-8-10 0:00: DD No Violations
-1740062729 2007-11-1 0:00: PW No Violations
-328170323 2018-12-6 0:00: UP No Violations
-695680321 2007-8-16 0:00: DD No Violations
-983225172 2007-9-5 0:00:0 DD No Violations
0328170323 2018-12-06 UrbanProduction Wells No Violations Access to the tank battery and wellhead was on a graveled driveway. The tank battery was surrounded with a locked board on board fence and an earthen dike. I. D. signage was posted and current. The equipment in the tank battery included two (2) 140 barrel stock tanks, one (1) 35 barrel poly brine tank, one (1) horizontal separator , one (1) orifice gas meter and one (1) Dominion / EOG meter station. The chart on the orifice gas meter reflected the current production period. The load lines were locked and plugged. The stock tanks had the required equipment per Senate Bill 165. The wellhead was surrounded with a locked board on board with current I.D. signage posted. The well was operated as an electric pumping well. There was a domestic gas connection attached to the casing. I spoke with John Difrangia (614.580.5796, Owner ) to express my concern regarding tree limbs overhanging the stock tanks. Mr. Difrangia said, He would have them removed. No further enforcement action will be taken once the limbs are removed.
0352862470 2007-08-07 Drill / Deepen / Reopen No Violations Poulson Drilling is moving on the location. The required sign and permit are posted along Albertson Parkway. No violations at this time.
0695680321 2007-08-16 Drill / Deepen / Reopen No Violations The drilling rig has moved off. The pits are lined and in good condition.
0983225172 2007-09-05 Drill / Deepen / Reopen No Violations The Uniontown office received a gas odor complaint from neighboring properties. This investigation found that Cutter had fraced the well on 9/4 and was flowing back into a frac tank. Cutter will be running tubing and rods later today which will stop any escaping natural gas. No violation at this time.
1171727137 2007-09-07 Drill / Deepen / Reopen No Violations The rods and tubing have been run and the pump jack has been set. The well is secure with no gas leaks. No violations at this time.
1247331845 2008-05-07 Preliminary Restoration No Violations Preliminary restoration is approved.
1304623805 2010-02-05 Drill / Deepen / Reopen No Violations checked site for tour on Senate Bill 165.
1583521067 2007-08-10 Drill / Deepen / Reopen No Violations Poulson is drilling ahead and should be ready to move on Monday. The pits are lined and fenced. No violations at this time.
1740062729 2007-11-01 Production Wells No Violations The well is in production. Preliminary restoration will be approved as soon as the temporary fence section on the north side of the tank battery is replaced with the permanent fence.
352862470 2007-8-7 0:00:0 DD No Violations

For data sources see[9]

References