34-153-23059

Well Details

Well ID: 34-153-23059
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DOMINION EAST OHIO
Well Pad ID:
Farm/Lease Name: HAER UNIT
License Status: Storage Well
License Date: 2014-03-05
Spud Date: 2008-11-03
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2008-11-07
Well Total Depth: 3993.00 ft
Configuration: Vertical
Latitude: 40.930000
Longitude: -81.620000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-08-19 Proposed Formations:CLINTON, Issued Date:8/19/2008, Expired Date:8/19/2009 6:00:00 AM, Drilling unit acres:26.5, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2008-10-21 Proposed Formations:CLINTON, Issued Date:10/21/2008, Expired Date:10/21/2009 6:00:00 AM, Drilling unit acres:25.33, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-11-07
Completion Report Received 2009-01-15
Change of Owner 2010-04-30 Operator changed from 8321, DOMINION EXPL& PROD INC to 8632, DOMINION FIELD SERVICES INC
Change of Owner 2014-02-20 Operator changed from 8632, DOMINION FIELD SERVICES INC to 240, DOMINION EAST OHIO
APP 2014-03-05 Proposed Formations:CLINTON, Issued Date:3/5/2014, Expired Date:3/4/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SO, Proposed Well Class:
Construction Permit Expires 2015-03-05
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-02-24 3758 3824 25
3758 3824 25
3758 3824 25

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 620 Mscf 65000 FRAC ALSO USED 1879 BBLS OF WATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 DOMINION EXPL& PROD INC 26144.00 0.00 23
2009 DOMINION EXPL& PROD INC 377364.00 0.00 365
2010 DOMINION FIELD SERVICES INC 127540.00 0.00 365
2011 DOMINION EAST OHIO 147786.00 0.00 365
2012 DOMINION FIELD SERVICES INC 165594.00 0.00 366
2013 DOMINION FIELD SERVICES INC 97052.00 31.00 355

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 DOMINION EXPL& PROD INC Brine 41 23
2009 DOMINION EXPL& PROD INC Brine 177 365
2010 DOMINION FIELD SERVICES INC Brine 0 365
2011 DOMINION EAST OHIO Brine 0 365
2012 DOMINION FIELD SERVICES INC Brine 141 366
2013 DOMINION FIELD SERVICES INC Brine 76 355

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-349054230 2008-12-2 0:00: DD No Violations
-822934302 2020-6-25 0:00: SO No Violations 0.50
-990679023 2019-2-20 0:00: SO No Violations 0.50
0120673250 2018-03-15 Storage Well No Violations I did a status check inspection for this storage well. The well is equipped with a plunger-lift system. The diked tank battery consists of a steel tank, a plastic brine tank, a vertical separator, a horizontal separator, a heater and two meters. The well is legibly identified. The well and tank battery are fenced in, gated and locked. No compliance issues are cited at this time.
0349054230 2008-12-02 Drill / Deepen / Reopen No Violations The location of the tank battery has been changed from what was discussed during the pre-permit site inspection. The landscaping/screening waiver which had been approved, is now denied. Landscaping and/or screening is now required around the wellhead and the tank battery. I also instructed Brian Morley with Dominion to submit a revised map showing the location of the tank battery.
0673734148 2017-01-30 Storage Well No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were closed. The well was fenced and locked. The tank battery still contained production equipment and consisted of one 100 BBL production tank, one 50 BBL poly brine tank, a mechanical separator, and a line heater. The valves on the separator were closed. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery. Lease access was stable. No violations at this time.
0767286001 2009-10-22 Preliminary Restoration No Violations Preliminary restoration is approved.
0990679023 2019-02-20 Storage Well No Violations My inspection found the well is equipped with a plunger-lift system. The diked tank battery consists of a steel tank, a plastic brine tank, a vertical separator, a horizontal separator, a heater and two meters. The well is legibly identified. The well and tank battery are fenced in, gated and locked. No compliance issues are cited at this time.
120673250 2018-3-15 0:00: SO No Violations 0.50
1227233111 2008-11-19 Drill / Deepen / Reopen No Violations The drilling pits were solidified and covered over. The well has been fraced and the service rig is on site flowing back the well.
1398744164 2008-11-12 Drill / Deepen / Reopen No Violations Wildcat moved off starting on 11/7. The pits are open, lined, fenced and in good condition. The site has been graded. No violations at this time.
1420552539 2014-12-26 UrbanProduction Wells No Violations I was on location to conduct a status check of this well. The well is of plunger lift construction. The tank battery consists of a 140 BBL production tank, mechanical separator, a 1500 gallon poly brine tank. The valves at the wellhead were open. The low pressure relief valve, spark arrestor and charcoal filter were installed on the 140 BBL production tank. The tank battery was diked. The fencing around the wellhead and tank battery is an 8 foot high chain link fence and topped with three strands of barbed wire. The man doors to the tank battery and well were locked. The well is properly identified with a clear, legibly marked well identification sign. The lease road is stable and drivable. No violations found.
673734148 2017-1-30 0:00: SO No Violations
767286001 2009-10-22 0:00 PL No Violations

For data sources see[9]