34-153-23095

Well Details

Well ID: 34-153-23095
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DOMINION EAST OHIO
Well Pad ID:
Farm/Lease Name: ROBIL UNIT
License Status: Storage Well
License Date: 2014-03-04
Spud Date: 2009-10-12
Spud Drilling Contractor: WHIPSTOCK OHIO DRILLING
Final Drill Date: 2009-10-18
Well Total Depth: 4013.00 ft
Configuration: Vertical
Latitude: 40.940000
Longitude: -81.620000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-08-31 Proposed Formations:CLINTON, Issued Date:8/31/2009, Expired Date:8/31/2010 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-10-18
Completion Report Received 2009-11-27
Change of Owner 2010-04-30 Operator changed from 8321, DOMINION EXPL& PROD INC to 8632, DOMINION FIELD SERVICES INC
Change of Owner 2014-02-20 Operator changed from 8632, DOMINION FIELD SERVICES INC to 240, DOMINION EAST OHIO
APP 2014-03-04 Proposed Formations:CLINTON, Issued Date:3/4/2014, Expired Date:3/3/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SO, Proposed Well Class:
Construction Permit Expires 2015-03-04
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-02-12 3819 3877 24
3819 3877 24
3819 3877 24

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 1797 Bbl 61754 622M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 DOMINION EXPL& PROD INC 1047.00 0.00 38
2010 DOMINION FIELD SERVICES INC 3887.00 88.00 245
2011 DOMINION EAST OHIO 4041.00 79.00 365
2012 DOMINION FIELD SERVICES INC 2759.00 47.00 366
2013 DOMINION FIELD SERVICES INC 1975.00 26.00 355

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 DOMINION EXPL& PROD INC Brine 0 38
2010 DOMINION FIELD SERVICES INC Brine 422 245
2011 DOMINION EAST OHIO Brine 0 365
2012 DOMINION FIELD SERVICES INC Brine 501 366
2013 DOMINION FIELD SERVICES INC Brine 326 355

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1826472681 2014-12-26 0:00 UP No Violations
-1916804372 2018-3-15 0:00: SO No Violations 0.50
-724292814 2009-10-22 0:00 DD No Violations
-787777382 2009-10-28 0:00 DD No Violations
-945241319 2017-1-30 0:00: SO No Violations
0228511595 2010-08-16 UrbanPreliminary Restoration No Violations Preliminary restoration is approved.
0724292814 2009-10-22 Drill / Deepen / Reopen No Violations Whipstock is still on site for maintenance. The 7 annular pressure was 0 psi and is still vented into a 300 bbl frac tank.
0787777382 2009-10-28 Drill / Deepen / Reopen No Violations The well will be fraced in the near future. The tank battery is under construction and the salesline is being installed.
0945241319 2017-01-30 Storage Well No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were closed. The well was fenced and locked. The tank battery still contained production equipment and consisted of one 100 BBL production tank, one 50 BBL poly brine tank, and a mechanical separator. The valves on the separator were closed. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery. Lease access was stable. No violations at this time.
1156595749 2009-10-17 Drill / Deepen / Reopen No Violations Ran cement bond log. Highest evidence of cement at 1370. Top of cement at 1704. DV tool at 2360. Pressure on 7 dia annulus was 350 psi. Will drill out cement and DV tool with 6-1/4 dia bit.
1255538837 2009-10-13 Drill / Deepen / Reopen No Violations Cemented surface casing. The drilling pits are fenced off and the pit liners are intact.
1256052744 2009-10-15 Drill / Deepen / Reopen No Violations Whipstock hit a solution mine void at 2846. Will set 7 dia casing and will do a 2-stage cement job using a DV tool.
1256053556 2009-10-16 Drill / Deepen / Reopen No Violations Cemented 7 casing (3208 set at 3220 KB) using a DV tool set at 2366. Lost circulation 40 bbls into the 2nd stage of displacement. Did not circulate cement to surface. Will wait on cement 12 hrs and run a cement bond log to determine height of cement on the back side of the 7.
1256310312 2009-10-20 Drill / Deepen / Reopen No Violations Drilling is completed but Whipstock is still on site for maintenance. The drilling pits are lined, fenced and in good condition. The 7 casing annulus is plumbed into a 300 bbl frac tank and open to prevent pressure build up.
1356617280 2012-12-26 Production Wells No Violations I inspected this location on 12/26/2012. This well is operated on a Plunger Lift System. All piping and fittings were found to be leak free and in working order. I found 580psi on the casing, 340 psi on the tubing, and 8 psi on the 8.625 annulus. Signage was in place and legible. The Tank battery consisted of a 140 Bbl. Stock tank, a 35 Bbl. Brine tank, 2408 Separator and Gas measuring station. All piping and tankage was found to be leak-free and in working order. No violations were identified at this time.
1550684284 2019-02-20 Storage Well No Violations My inspection found the well is equipped with a plunger-lift system. There is a domestic gas connection. The diked tank battery consists of a steel tank, a plastic brine tank, a meter run, a vertical and horizontal separator. The well is legibly identified. No compliance issues are cited at this time.
1775607683 2020-6-25 0:00: SO No Violations 0.50
1826472681 2014-12-26 UrbanProduction Wells No Violations I was on location to conduct a status check of this well. The well is of plunger lift construction. The tank battery consists of a 140 BBL production tank, mechanical separator, a 1500 gallon poly brine tank. The valves at the wellhead were open. The low pressure relief valve, spark arrestor and charcoal filter were installed on the 140 BBL production tank. The tank battery was diked. The fencing around the wellhead and tank battery is an 8 foot high chain link fence with green privacy slats and topped with three strands of barbed wire. The man doors to the tank battery and well were locked. The well is properly identified with a clear, legibly marked well identification sign. The lease road is stable and drivable. No violations found.
1916804372 2018-03-15 Storage Well No Violations I did a status check inspection for this storage well. The well is equipped with a plunger-lift system. There is a domestic gas connection. The diked tank battery consists of a steel tank, a plastic brine tank, a vertical separator, a horizontal separator and two meters. The well is legibly identified. The well and tank battery are fenced in, gated and locked. No compliance issues are cited at this time.
228511595 2010-8-16 0:00: UL No Violations

For data sources see[9]

References