Well ID: 34-153-23095 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.94,"lon":-81.62,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: DOMINION EAST OHIO | |
Well Pad ID: | |
Farm/Lease Name: ROBIL UNIT | |
License Status: Storage Well | |
License Date: 2014-03-04 | |
Spud Date: 2009-10-12 | |
Spud Drilling Contractor: WHIPSTOCK OHIO DRILLING | |
Final Drill Date: 2009-10-18 | |
Well Total Depth: 4013.00 ft | |
Configuration: Vertical | |
Latitude: 40.940000 | |
Longitude: -81.620000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2009-08-31 | Proposed Formations:CLINTON, Issued Date:8/31/2009, Expired Date:8/31/2010 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2009-10-18 | |
Completion Report Received | 2009-11-27 | |
Change of Owner | 2010-04-30 | Operator changed from 8321, DOMINION EXPL& PROD INC to 8632, DOMINION FIELD SERVICES INC |
Change of Owner | 2014-02-20 | Operator changed from 8632, DOMINION FIELD SERVICES INC to 240, DOMINION EAST OHIO |
APP | 2014-03-04 | Proposed Formations:CLINTON, Issued Date:3/4/2014, Expired Date:3/3/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SO, Proposed Well Class: |
Construction Permit Expires | 2015-03-04 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-02-12 | 3819 | 3877 | 24 |
3819 | 3877 | 24 | |
3819 | 3877 | 24 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 1797 Bbl | 61754 | 622M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | DOMINION EXPL& PROD INC | 1047.00 | 0.00 | 38 |
2010 | DOMINION FIELD SERVICES INC | 3887.00 | 88.00 | 245 |
2011 | DOMINION EAST OHIO | 4041.00 | 79.00 | 365 |
2012 | DOMINION FIELD SERVICES INC | 2759.00 | 47.00 | 366 |
2013 | DOMINION FIELD SERVICES INC | 1975.00 | 26.00 | 355 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | DOMINION EXPL& PROD INC | Brine | 0 | 38 |
2010 | DOMINION FIELD SERVICES INC | Brine | 422 | 245 |
2011 | DOMINION EAST OHIO | Brine | 0 | 365 |
2012 | DOMINION FIELD SERVICES INC | Brine | 501 | 366 |
2013 | DOMINION FIELD SERVICES INC | Brine | 326 | 355 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1826472681 | 2014-12-26 0:00 | UP | No Violations | |
-1916804372 | 2018-3-15 0:00: | SO | No Violations | 0.50 |
-724292814 | 2009-10-22 0:00 | DD | No Violations | |
-787777382 | 2009-10-28 0:00 | DD | No Violations | |
-945241319 | 2017-1-30 0:00: | SO | No Violations | |
0228511595 | 2010-08-16 | UrbanPreliminary Restoration | No Violations | Preliminary restoration is approved. |
0724292814 | 2009-10-22 | Drill / Deepen / Reopen | No Violations | Whipstock is still on site for maintenance. The 7 annular pressure was 0 psi and is still vented into a 300 bbl frac tank. |
0787777382 | 2009-10-28 | Drill / Deepen / Reopen | No Violations | The well will be fraced in the near future. The tank battery is under construction and the salesline is being installed. |
0945241319 | 2017-01-30 | Storage Well | No Violations | At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were closed. The well was fenced and locked. The tank battery still contained production equipment and consisted of one 100 BBL production tank, one 50 BBL poly brine tank, and a mechanical separator. The valves on the separator were closed. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery. Lease access was stable. No violations at this time. |
1156595749 | 2009-10-17 | Drill / Deepen / Reopen | No Violations | Ran cement bond log. Highest evidence of cement at 1370. Top of cement at 1704. DV tool at 2360. Pressure on 7 dia annulus was 350 psi. Will drill out cement and DV tool with 6-1/4 dia bit. |
1255538837 | 2009-10-13 | Drill / Deepen / Reopen | No Violations | Cemented surface casing. The drilling pits are fenced off and the pit liners are intact. |
1256052744 | 2009-10-15 | Drill / Deepen / Reopen | No Violations | Whipstock hit a solution mine void at 2846. Will set 7 dia casing and will do a 2-stage cement job using a DV tool. |
1256053556 | 2009-10-16 | Drill / Deepen / Reopen | No Violations | Cemented 7 casing (3208 set at 3220 KB) using a DV tool set at 2366. Lost circulation 40 bbls into the 2nd stage of displacement. Did not circulate cement to surface. Will wait on cement 12 hrs and run a cement bond log to determine height of cement on the back side of the 7. |
1256310312 | 2009-10-20 | Drill / Deepen / Reopen | No Violations | Drilling is completed but Whipstock is still on site for maintenance. The drilling pits are lined, fenced and in good condition. The 7 casing annulus is plumbed into a 300 bbl frac tank and open to prevent pressure build up. |
1356617280 | 2012-12-26 | Production Wells | No Violations | I inspected this location on 12/26/2012. This well is operated on a Plunger Lift System. All piping and fittings were found to be leak free and in working order. I found 580psi on the casing, 340 psi on the tubing, and 8 psi on the 8.625 annulus. Signage was in place and legible. The Tank battery consisted of a 140 Bbl. Stock tank, a 35 Bbl. Brine tank, 2408 Separator and Gas measuring station. All piping and tankage was found to be leak-free and in working order. No violations were identified at this time. |
1550684284 | 2019-02-20 | Storage Well | No Violations | My inspection found the well is equipped with a plunger-lift system. There is a domestic gas connection. The diked tank battery consists of a steel tank, a plastic brine tank, a meter run, a vertical and horizontal separator. The well is legibly identified. No compliance issues are cited at this time. |
1775607683 | 2020-6-25 0:00: | SO | No Violations | 0.50 |
1826472681 | 2014-12-26 | UrbanProduction Wells | No Violations | I was on location to conduct a status check of this well. The well is of plunger lift construction. The tank battery consists of a 140 BBL production tank, mechanical separator, a 1500 gallon poly brine tank. The valves at the wellhead were open. The low pressure relief valve, spark arrestor and charcoal filter were installed on the 140 BBL production tank. The tank battery was diked. The fencing around the wellhead and tank battery is an 8 foot high chain link fence with green privacy slats and topped with three strands of barbed wire. The man doors to the tank battery and well were locked. The well is properly identified with a clear, legibly marked well identification sign. The lease road is stable and drivable. No violations found. |
1916804372 | 2018-03-15 | Storage Well | No Violations | I did a status check inspection for this storage well. The well is equipped with a plunger-lift system. There is a domestic gas connection. The diked tank battery consists of a steel tank, a plastic brine tank, a vertical separator, a horizontal separator and two meters. The well is legibly identified. The well and tank battery are fenced in, gated and locked. No compliance issues are cited at this time. |
228511595 | 2010-8-16 0:00: | UL | No Violations |
For data sources see[9]