34-153-23125

Well Details

Well ID: 34-153-23125
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Richfield Township
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: MATA UNIT
License Status: Producing
License Date: 2011-01-28
Spud Date: 2011-04-12
Spud Drilling Contractor:
Final Drill Date: 2011-04-17
Well Total Depth: 3816.00 ft
Configuration: Vertical
Latitude: 41.260000
Longitude: -81.620000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-01-28 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:1/28/2011, Expired Date:1/27/2013 12:00:00 PM, Drilling unit acres:36.79, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-04-17
Completion Report Received 2011-06-07
Construction Permit Expires 2012-01-28
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-08-12 3536 3579 71
3536 3579 71
3536 3579 71

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-05-10 H2O 15 93065 Gal 60000 Producers Service Corporation

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 OHIO VALLEY ENERGY SYSTEMS COR 0.00 100.00 15
2012 OHIO VALLEY ENERGY SYSTEMS COR 4875.00 2393.00 330
2013 OHIO VALLEY ENERGY SYSTEMS COR 15521.00 3506.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 19673.00 2718.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 10099.00 1301.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 8494.00 891.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 7010.00 1047.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 6866.00 820.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 40 15
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 149 330
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 220 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 162 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 68 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 30 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1151620772 2011-4-21 0:00: UD No Violations
-1513241530 2011-5-10 0:00: UD No Violations
-1820054244 2011-7-13 0:00: UD No Violations
-1906505944 2011-4-25 0:00: UD No Violations
-458077968 2011-11-30 0:00 UL No Violations
-547636434 2011-4-28 0:00: UD No Violations
0167006008 2011-06-20 Urban Drill / Deepen / Reopen No Violations The well has been fraced and the tank battery is under construction. Ohio Valley is also starting to work on reclamation. No violations at this time.
0458077968 2011-11-30 UrbanPreliminary Restoration No Violations Preliminary Restoration is approved.
0547636434 2011-04-28 Urban Drill / Deepen / Reopen No Violations Dons Excavating and Chem Tech were on site to solidify the drilling pits. Chem Tech placed one load of dust (approximately 22 tons) into each pit. After mixing, Dons Excavating covered each pit with available subsoil.
1151620772 2011-04-21 Urban Drill / Deepen / Reopen No Violations Wildcat Drilling is still on location and rigging down. Pit solidification and closure is scheduled for 4/25.
1313596774 2011-08-08 Preliminary Restoration No Violations The site has been graded, seeded and mulched. Preliminary restoration will be approved if the vegetation establishes. The tank battery is under construction and needs to be fenced.
1318361417 2011-04-12 Urban Drill / Deepen / Reopen No Violations Wildcat Drilling is moving on location and will spud the well later this afternoon. No violations at this time.
1470129350 2011-09-20 Urban Drill / Deepen / Reopen No Violations The majority of the affected area has been graded, seeded and mulched. A small area west of the tank battery still needs attention and the salesline/houseline excavation trenches need graded, seeded and mulched. According to OVE, the landowner is being paid to repair the parking lot and plant any trees that he may want on the lot.
1513241530 2011-05-10 Urban Drill / Deepen / Reopen No Violations Producers Service Corporation was on site to frac the well. The frac data will be submitted in the completion module of RBDMS.
167006008 2011-6-20 0:00: UD No Violations
1820054244 2011-07-13 Urban Drill / Deepen / Reopen No Violations Preliminary restoration is due soon and work still needs to be done to satisfy the restoration requirements. I talked to Ted Hill and Ben Funderberg about finishing the work as soon as possible. They both agreed that the work needs to be done and will be done.
1906505944 2011-04-25 Urban Drill / Deepen / Reopen No Violations Wildcat Drilling equipment is still on site. Pit solidification has been postponed until April 28. The pits have been pumped down and have sufficient freeboard. No violations at this time.
2092036575 2015-03-18 UrbanProduction Wells No Violations I inspected the Matta #1 well on 3/18/2015. The well is operated as a plunger lift well with 1.5 tubing inside of 4.5 production casing. The tubing pressure was 340 psi. with the 4.5 casing being 400 psi.. There are three (3) domestic house taps connected to the well. The well head was leak free. The well head is fenced with plank on plank fencing and was secured with a lock. The required signage was on the well fencing. The tank battery consists of a 140 barrel oil tank, 25 barrel poly brine, a 2408 horizontal mechanical separator and a DOM/EOG meter station. The load lines were locked and secure with flat plugs. I spoke with Ted Hill ( OVE ) to have a small amount of oil residue removed. All other fittings and equipment was free of leaks. The tank battery is surounded by an earthen dike and is fenced with plank on plank fencing. All locks were in place and working. The required I.D. signage was in place and legible. No violations were identified during this inspection.

For data sources see[9]