34-153-23154

Well Details

Well ID: 34-153-23154
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: INDUSTRY STANDARD SUPPLIES INC
Well Pad ID:
Farm/Lease Name: LOYAL OAKS SWIM CLUB
License Status: Producing
License Date: 2012-08-20
Spud Date: 2012-08-27
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2012-09-03
Well Total Depth: 3975.00 ft
Configuration: Vertical
Latitude: 41.050000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-08-20 Proposed Formations:CLINTON, Issued Date:8/20/2012, Expired Date:8/20/2014 12:00:00 PM, Drilling unit acres:20.925, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2012-08-31 CORRECTION TO CASING PROGRAM .
Reached Total Depth 2012-09-03
Completion Report Received 2013-03-21
Construction Permit Expires 2013-08-20
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2013-03-21 3754 3834 132
3754 3834 132
3754 3834 132

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-09-24 H2O 15 54326 Gal 30000 Superior Well Services

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 COLLINS JOHN 0.00 0.00 0
2013 INDUSTRY STANDARD SUPPLIES INC 6822.00 219.00 365
2014 INDUSTRY STANDARD SUPPLIES INC 4214.00 106.00 365
2015 INDUSTRY STANDARD SUPPLIES INC 3756.00 118.00 365
2016 INDUSTRY STANDARD SUPPLIES INC 2326.00 0.00 365
2017 INDUSTRY STANDARD SUPPLIES INC 2252.00 97.00 365
2018 INDUSTRY STANDARD SUPPLIES INC 1197.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 COLLINS JOHN Brine 0 0
2013 INDUSTRY STANDARD SUPPLIES INC Brine 393 365
2014 INDUSTRY STANDARD SUPPLIES INC Brine 85 365
2015 INDUSTRY STANDARD SUPPLIES INC Brine 565 365
2016 INDUSTRY STANDARD SUPPLIES INC Brine 399 365
2017 INDUSTRY STANDARD SUPPLIES INC Brine 293 365
2018 INDUSTRY STANDARD SUPPLIES INC Brine 282 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1933104074 2014-12-8 0:00: UP No Violations
1457968246 2016-03-14 UrbanProduction Wells No Violations This inspection ( 03/14/2016 ) was conducted to access the compliance with a previously issued Compliance Notice ( # 18264471477 ). The prior deficiences included I.D. signage, locks on load lines and a pop off valve on the 8.625 to 4.5 annular space. My inspection indicated that all item noted previously have been brought into compliance. No further violations noted.
1933104074 2014-12-08 UrbanProduction Wells Violations Noted I inspected this well on 12/8/2014. The lease road is graveled and passable. All the facilities ( wellhead and tank battery ) are fenced. The well was operated as a pumping well utilizing an electrified Linear Rod Pump. The construction of the well has 2.375 upset tubing inside 4.5 casing. All piping and fittings were leak free at the wellhead. The pop-off on the 8.625 casing was lacking the required pressure gauge. The tank battery consisted of a 210 barrel oil tank, 100 barrel brine tank and a hornizontal mechanical separator. The load lines were equipped with flat plugs, but were not locked. The require urban signage was absent. There were non-essential items ( frac valve, safety fence, etc. ) that need to be removed from the tank battery.In order to bring the Loyal Oaks Swim Club # 1 into compliance the Operator shall, 1.) Place the required Urban signage at the well and tank battery, 2.) Place locks on the load lines of all tanks, 3.) Place the required gauge on the 8.625 pop-off manifold and expose the valves, 4.) remove all non-essential items ( frac valve, safety fence, etc. ) from the tank battery. These corrective measure shall be completed and approved ( by DOGRM Inspector ) by 1/23/2015

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1933104074 US-OH-119456 2016-10-25 ID (a-i)
1933104074 US-OH-119457 2016-10-25 LOCKS

For data sources see[9]

References