Well Details

Well ID: 34-153-23162
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DISCOVERY OIL AND GAS
Well Pad ID:
Farm/Lease Name: GOODVIEW PARK UNIT
License Status: Producing
License Date: 2013-06-28
Spud Date: 2014-06-16
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2013-06-28
Well Total Depth: 4622.00 ft
Configuration: Directional
Latitude: 41.060000
Longitude: -81.450000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-06-28 Proposed Formations:CLINTON, Issued Date:6/28/2013, Expired Date:6/28/2015 12:00:00 PM, Drilling unit acres:22.81, Proposed Well Type:OG, Proposed Well Class:
Reached Total Depth 2013-06-28
Construction Permit Expires 2014-06-28
Completion Report Received 2014-09-30
Correction to Well 2015-01-09 CHANGE IN TARGET INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. DIRECTIONAL WELL. UNIT SIZE DECREASED TO 24.02 ACRES.
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-10-06 3943 3993 65
3943 3993 65
3943 3993 65

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 07/15/2014 07/15/2014 4439 98380 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Discovery Oil & Gas Water Water 7732-18-5 100 90.2927 0
Super-Flo RPM Nabors Completion and Production Services Surfactants & Foamers Proprietary Proprietary 40 0.022033 0
D-Limonene 5989-27-5 20 0.011016 0
N-Methyl Pyrrolidone 872-50-4 30 0.016525 0
Proprietary Proprietary 20 0.011016 0
Isopropanol 67-63-0 20 0.011016 0
Other Ingredients Nabors Completion and Production Services Other Ingredients Anionic Polyacrylamide 910644-97-2 40 0.045311 0
Proprietary Proprietary 2 0.002266 0
Proprietary Proprietary 10 0.005508 0
Water 7732-18-5 40 0.022033 0
Water 7732-18-5 48 0.000436 0
Propylene glycol 57-55-6 15 0.016992 0
Dioxane 123-91-1 1 0.00000900 0
Demineralized Water 7732-18-5 50 0.001106 0
anionic copolymer Proprietary 20 0.000442 0
Water 7732-18-5 40 0.045311 0
Glycerin 56-81-5 55 0.001217 0
Water 7732-18-5 50 0.014134 0
2-Butoxyethanol 111-76-2 13 0.000118 0
Proprietary Proprietary 25 0.013771 0
Iron Acid 3M (12.6%-18.0%) Nabors Completion and Production Services Acid Blends Citric Acid 77-92-9 100 0.006543 0
Water 7732-18-5 100 0.323864 0
7647-01-0 100 0.330406 0
PA Specific 20/40 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Titanium Oxide 13463-67-7 0.1 0.007703 0
Iron Oxide 1309-37-1 0.1 0.007703 0
Crystalline Silica, quartz 14808-60-7 99.9 7.69562 0
Aluminum Oxide 1344-28-1 1.1 0.084737 0
Acid Inhibitor 2 (AI-2) Nabors Completion and Production Services Acid Corrosion Inhibitors Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 10 0.00009100 0
Propargyl Alcohol 107-19-7 40 0.000363 0
Isopropyl Alcohol 67-63-0 40 0.000363 0
Glycol Ethers 111-46-6 40 0.000363 0
Ethoxylated Nonylphenol 68412-54-4 13 0.000118 0
Super GREEN SOLV Nabors Completion and Production Services Paraffin & Scale Additives BTEX Free Aliphatic Hydrocarbon 64742-96-7 100 0.041393 0
Breaker FR Nabors Completion and Production Services Gel Breakers ferrous sulfate 7782-63-0 20 0.000442 0
Aliphatic Acid Proprietary 20 0.000442 0
BioClear 1000 Nabors Completion and Production Services Biocides 2,2-Dibromo-3-nitrilo-propionamide (DBNPA) 10222-01-2 100 0.001541 0
IC-100L Nabors Completion and Production Services Iron Control Additives Citric Acid Anhydrous 77-92-9 50 0.014134 0
WFR-3B Nabors Completion and Production Services Friction Reducer Ethoxylated oleylamine 26635-93-8 5 0.005664 0
Ethoxylated alcohols 68002-97-1 15 0.016992 0
Hydrotreated light distillates, non-aromatic, BTEX free 64742-47-8 30 0.033983 0
PA Specific 100 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Iron Oxide 1309-37-1 0.1 0.0011 0
Aluminum Oxide 1344-28-1 1.1 0.012105 0
Crystalline Silica, quartz 14808-60-7 99.9 1.09937 0
Titanium Oxide 13463-67-7 0.1 0.0011 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 Bbl 0
2013-07-15 H2O 0 98380 Gal 80000 OTHER Nabor Completion Services

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2016 DISCOVERY OIL AND GAS 0.00 0.00 0
2017 DISCOVERY OIL AND GAS 390.00 157.00 31
2018 DISCOVERY OIL AND GAS 0.00 319.00 60

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2016 DISCOVERY OIL AND GAS Brine 0 0
2017 DISCOVERY OIL AND GAS Brine 1281 31
2018 DISCOVERY OIL AND GAS Brine 0 60

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1883062388 2016-10-17 0:00 UP No Violations
-2047044130 2016-6-28 0:00: WR No Violations
1209162947 2014-06-18 Casing String Witnessed No Violations
1473170007 2016-07-19 Work Over Reconditioning No Violations I was on location to observe the re-frac of the Goodview Park # 1-D. Producers Service Corp. was the stimulation contractor. There was not a noticeable Breakdown pressure observed. The well treated at 1720 psi @ 12.5 bpm. A total of 150 sacks of 20/50 sand were used. Average treating pressure was 1664 psi. Total job volume was 34,000 gallons of fluid. Five (5) minute shut in pressure was 1406 psi. No violations were identified.
1541651276 2016-07-20 Work Over Reconditioning No Violations I conducted a status check on this location after the frac job. Bishop Well Services was sand pumping the 4.5 casings rathole. Very little ( less than five (5) gallon bucket ) material and sand was recovered from the well. There was not any pressure or shows of oil. No violations identified .
1883062388 2016-10-17 UrbanProduction Wells No Violations The Goodview Park Unit # 1 - D well is operated as an electric pumping unit. The access to the well head was gained by using a grass path as the well was located on park land. The well had a ten ( 10 ) foot fence topped with five ( 5 ) strands of barbed wire. The I.D. signage had the proper information and was of the required letter size. I requested that the sign be relocated to allow visibility from the street. The fencing was locked. The well head was configured as a typical pumping well head. The 8.625 riser was present, but lacked the required gauge. The electric box did not have the required lock. Both these inadequacies were address with Operator. The tank battery was located in an industrial park, which afforded sufficent access. The tank battery consisted of two ( 2 ) 210 barrel stock tanks, one ( 1 ) 100 barrel steel brine tank, two ( 2 ) 25 barrel poly brine tanks and two ( 2 ) horizontal ( 2408 ) mechanical separators. The stock tanks were equipped with charcoal filters, lightening arrestors and pressurized inspection hatches. The required spacing was observed between the tank battery equipment. The load lines were locked and plugged. The tank battery was surrounded with a ten ( 10 ) foot fence topped with five ( 5 ) strans of barbed wire and one ( 1 ) strand of concertina ribbon. An earthen dike surrounded the tank battery. I will re - inspect the pumping unit to ensure the inadequencies previous mentioned are address.
2047044130 2016-06-28 Work Over Reconditioning No Violations I inspected the Goodview Park well # 1-D to review the preparations for a remedial polymer treatment to control the excessive production water production. The Operator decided to treat the well with a polymer fluid inorder to control excessive water production and refrac the well. On location was a 300 barrel fresh water tank ( filled with hydrant water), enclosed pumping and chemical equipment trailers and a generator set. The location was surrounded with silt filter sock on the southern border. At the time of my visit Flotek, Ind. was pumping treatment fluids downhole at a rate of 1.5 bpm with a pressure of 680 psi. down the 2.375 tubing. No violations were observed during this inspection.

For data sources see[10]