34-155-21668

Well Details

Well ID: 34-155-21668
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Brookfield Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: TODUT L& E
License Status: Producing
License Date: 1980-12-18
Spud Date: 1981-02-20
Spud Drilling Contractor:
Final Drill Date: 1981-02-26
Well Total Depth: 4950.00 ft
Configuration: Vertical
Latitude: 41.270000
Longitude: -80.570000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-12-18 54 TITAN ENERGY CORP GeoDate 12/18/80
Oil and Gas 1980-12-18 Issued Date 12/18/80 Expired Date Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1981-02-20
Completed 1981-02-26
Reached Total Depth 1981-02-26
Completion Report Received 1981-12-18
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Change of Owner 2017-04-13 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-04-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4770 4870 22
4770 4870 22
4770 4870 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 228 Mscf 0
H2O 0 78000 Gal 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TITAN ENERGY CORP 12388.00 142.00 0
1985 TITAN ENERGY CORP 9069.00 59.00 365
1986 TITAN ENERGY CORP 8486.00 75.00 365
1987 TITAN ENERGY CORP 6488.00 74.00 365
1988 TITAN ENERGY CORP 6228.00 74.00 365
1989 TITAN ENERGY CORP 5035.00 49.00 365
1990 TITAN ENERGY CORP 3310.00 0.00 365
1991 TITAN ENERGY CORP 2287.00 72.00 365
1992 TITAN ENERGY CORP 2883.00 0.00 365
1993 TITAN ENERGY CORP 2226.00 0.00 365
1994 TITAN ENERGY CORP 1323.00 0.00 365
1997 TITAN ENERGY CORP 1321.00 0.00 245
2000 BIG SKY ENERGY INC 1226.00 3.00 365
2001 BIG SKY ENERGY INC 1652.00 86.00 365
2002 BIG SKY ENERGY INC 804.00 48.00 365
2003 BIG SKY ENERGY INC 4942.00 0.00 365
2004 BIG SKY ENERGY INC 2596.00 0.00 365
2005 BIG SKY ENERGY INC 1842.00 18.00 365
2006 BIG SKY ENERGY INC 1760.00 0.00 365
2007 BIG SKY ENERGY INC 1429.00 31.00 365
2008 BIG SKY ENERGY INC 1570.00 33.00 365
2009 BIG SKY ENERGY INC 1790.00 0.00 365
2010 BIG SKY ENERGY INC 1208.00 0.00 365
2011 BIG SKY ENERGY INC 897.00 0.00 365
2012 BIG SKY ENERGY INC 2554.00 16.00 366
2013 BIG SKY ENERGY INC 757.00 0.00 365
2014 BIG SKY ENERGY INC 1599.00 0.00 365
2016 BIG SKY ENERGY INC 147.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TITAN ENERGY CORP Brine 0 0
1985 TITAN ENERGY CORP Brine 0 365
1986 TITAN ENERGY CORP Brine 0 365
1987 TITAN ENERGY CORP Brine 0 365
1988 TITAN ENERGY CORP Brine 0 365
1989 TITAN ENERGY CORP Brine 0 365
1990 TITAN ENERGY CORP Brine 0 365
1991 TITAN ENERGY CORP Brine 0 365
1992 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 0 365
1994 TITAN ENERGY CORP Brine 0 365
1997 TITAN ENERGY CORP Brine 245
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1019546349 2016-4-15 0:00: PW No Violations
-619705678 2014-10-8 0:00: AM No Violations
0000PL4094 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0219189786 2016-08-31 Production Wells No Violations I was on location to assess compliance notice # -
0619705678 2014-10-08 Administrative Inspection No Violations The company has received a stay from the chiefs order and is allowed to operate their wells. The compliance notice on the well can be removed.
0707001046 2019-02-05 UrbanProduction Wells No Violations I was on location to assess compliance notice 1019546349, regarding the installation of identification at the well and tank battery location. At the time of my inspection, the well was equipped with a plunger lift assembly and in production. The tank battery was comprised of a 100 BBL tank and a mechanical separator. There was also a 50 BBL tank and separator located due east of the 100 BBL tank. There was identification that has been installed on the well and 100 BBL tank with the current owner/operator information. The lease access was stable. Compliance notice closed.
1019546349 2016-04-15 Production Wells Violations Noted My inspection found the well to be equipped with a plunger lift unit. The valves on the wellhead leading into the flow line are open. The tank battery consists of a 100 BBL production tank. The heated separator is outside of the tank battery with the proper spacing. The flow line valve leading into the separator and the sales line valve leaving the separator are open. The production chart in the meter box was last changed on 2/29/16. The well is in production. There is a 25 BBL tank sitting 20 ft outside of the tank battery that is not currently being used and needs removed from the location. There is a second separator on location for the sales line. The sales line separator is connected to a 50 BBL tank. The dike around the 50 BBL tank needs to be rebuilt. The proper identification was located on the tank battery. The wellheads identification sign was ilegible and needs replaced. The lease road is in stable condition and is secured by a wire gate. The tank battery and lease road are being shared by permit 2-1669. The well needs shut in immediately per the temporary restraining order issued by the Trumbull County Court of Common Pleas, dated 4/11/2016.
1062106771 2013-12-10 UrbanProduction Wells No Violations My inspection for Complaint #4200 and #4452 found the small trees in the tank battery cut down and removed per my request. The proper identification signs were posted at the well and tank battery. The overgrown weeds were cut down. A plug was installed on the load line.
1359388765 2013-01-28 UrbanProduction Wells No Violations My inspection found the well equipped with a plunger lift unit. It had no identification sign. The tank battery contained one, 100 barrel production tank. The identification sign stenciled onto the tank with half of the proper information. There was no plugs on the load lines. The dike was weathered; however, it meets containment requirements. The separator was in good working condition. There was one, 50 barrel brine tank next to a vertical drip tank at the sales flow line. The 7 day production chart was located next to the sales flow line. The well shares the production tank and separator with permit number 2-1699. The lease road was in stable condition with a locked wire steel line at the entrance. This well was placed in production prior to House Bill 278. I called Jamie Campbell at 440-858-7252. I instructed him to install the plugs on the load lines and place an identification sign on the well. I will re-inspect by 2/8/2013.
1393361792 2014-02-25 Production Wells Violations Noted I was on location today with O.D.N.R. Supervisor Tom Hill to check compliance of Chiefs Order # 2014-43. My inspection found the well to be equipped with a plunger lift unit. The demco valve and the valve leading to the flow line on the wellhead are open. There is a 100 BBL production tank surrounded by a proper dike. The heat treated separator has the proper spacing. The flow line valve leading into the separator is currently open. The sales line valve leading out of the separator is currently open. There is a 25 BBL tank sitting 20 ft outside of the tank battery that is not currently being used. There is a second separator on location for the sales line. The sales line separator is connected to a 50 BBL tank. The production chart in the separator and the production chart on the sales line show the well has been produced since the last chart change on 2-24-2014. The proper identification was located on the tank battery. The lease road is in stable condition and is secured by a wire gate. The lease road and tank battery are being shared by permit 2-1699. The well is in production which is in non-compliance of Chiefs Order # 2014-43. The well needs to be shut-in immediately.
1672188382 2014-02-28 Production Wells No Violations My inspection today is a follow-up inspection to Compliance Notice # 1393361792, which was issued for non-compliance of Chiefs Order # 2014-43. My inspection found the well to be equipped with a plunger lift unit. The demco valve and the valve leading to the flow line on the wellhead are open. There is a 100 BBL production tank surrounded by a proper dike. The heat treated separator has the proper spacing. The flow line valve leading into the separator is currently open. The sales line valve leading out of the separator is currently open. There is a 25 BBL tank sitting 20 ft outside of the tank battery that is not currently being used. There is a second separator on location for the sales line. The sales line separator is connected to a 50 BBL tank. The production chart in the separator and the production chart on the sales line show the well is still being produced since the last inspection on 2-25-2014. The proper identification was located on the tank battery. The lease road is in stable condition and is secured by a wire gate. The lease road and tank battery are being shared by permit 2-1699. The well is in production which is in non-compliance of Chiefs Order # 2014-43. The well needs to be shut-in immediately.
1753601968 2013-09-23 UrbanProduction Wells No Violations My inspection found the weeds and small trees not removed or cut down from around the well, tank battery, or separator per my request.
219189786 2016-8-31 0:00: PW No Violations 0.50
707001046 2019-2-5 0:00:0 UP No Violations 0.70
PL4094 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1019546349 US-OH-100272 2016-06-14 Failure to legibly identify well
1393361792 US-OH-111630 2014-11-17 Failure to register/obtain or maintain bond/insurance

For data sources see[9]

References