X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-21699

Well Details

Well ID: 34-155-21699
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Brookfield Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: TODUT L& E
License Status: Producing
License Date: 1980-12-29
Spud Date: 1982-01-11
Spud Drilling Contractor:
Final Drill Date: 1982-01-16
Well Total Depth: 4998.00 ft
Configuration: Vertical
Latitude: 41.260000
Longitude: -80.570000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-12-29 54 TITAN ENERGY CORP GeoDate 12/29/80
Oil and Gas 1980-12-29 Issued Date 12/29/80 Expired Date Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1982-01-11
Completed 1982-01-16
Reached Total Depth 1982-01-16
Completion Report Received 1982-03-18
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Change of Owner 2017-04-13 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-04-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4780 4842 24
4780 4842 24
4780 4842 24

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 198 Mscf 0
H2O 0 60000 Gal 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TITAN ENERGY CORP 8198.00 68.00 0
1985 TITAN ENERGY CORP 5982.00 58.00 365
1986 TITAN ENERGY CORP 3882.00 73.00 365
1987 TITAN ENERGY CORP 3163.00 0.00 365
1988 TITAN ENERGY CORP 3706.00 73.00 365
1989 TITAN ENERGY CORP 2958.00 72.00 365
1990 TITAN ENERGY CORP 1935.00 44.00 365
1991 TITAN ENERGY CORP 1255.00 0.00 365
1992 TITAN ENERGY CORP 2684.00 0.00 365
1993 TITAN ENERGY CORP 1856.00 58.00 365
1994 TITAN ENERGY CORP 1013.00 0.00 365
1997 TITAN ENERGY CORP 1335.00 52.00 245
2000 BIG SKY ENERGY INC 2239.00 114.00 365
2001 BIG SKY ENERGY INC 2679.00 40.00 365
2002 BIG SKY ENERGY INC 1987.00 42.00 365
2003 BIG SKY ENERGY INC 265.00 0.00 365
2004 BIG SKY ENERGY INC 2753.00 52.00 365
2005 BIG SKY ENERGY INC 1842.00 18.00 365
2006 BIG SKY ENERGY INC 1761.00 0.00 365
2007 BIG SKY ENERGY INC 1429.00 31.00 365
2008 BIG SKY ENERGY INC 1571.00 33.00 365
2009 BIG SKY ENERGY INC 1791.00 0.00 365
2010 BIG SKY ENERGY INC 1208.00 0.00 365
2011 BIG SKY ENERGY INC 897.00 0.00 365
2012 BIG SKY ENERGY INC 2554.00 16.00 366
2013 BIG SKY ENERGY INC 757.00 0.00 365
2014 BIG SKY ENERGY INC 1599.00 0.00 365
2016 BIG SKY ENERGY INC 147.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TITAN ENERGY CORP Brine 0 0
1985 TITAN ENERGY CORP Brine 0 365
1986 TITAN ENERGY CORP Brine 0 365
1987 TITAN ENERGY CORP Brine 0 365
1988 TITAN ENERGY CORP Brine 0 365
1989 TITAN ENERGY CORP Brine 0 365
1990 TITAN ENERGY CORP Brine 0 365
1991 TITAN ENERGY CORP Brine 0 365
1992 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 0 365
1994 TITAN ENERGY CORP Brine 0 365
1997 TITAN ENERGY CORP Brine 10 245
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1280505197 2016-8-31 0:00: UP No Violations 0.30
0000PL4084 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1280505197 2016-08-31 UrbanProduction Wells No Violations I was on location to assess compliance notice # 1427060378. At the time of my inspection, I found the well not in production. The well is equipped with a plunger lift assembly. The gate valve and the flow line valve plumbed off of the tubing are closed. There is no domestic gas supply. There is a 25 bbl. storage tank outside the diked 100 bbl. storage tank not in use and needs removed. A 50 bbl. storage tank next to a vertical separator does not meet spacing requirements. There is a stenciled identification sign on the 100 bbl. storage tank with faded and unreadable well information.
1359641289 2013-01-31 UrbanProduction Wells No Violations My inspection found the well equipped with a plunger lift unit surrounded by overgrown weeds. It had no identification sign. The tank battery contained one, 100 barrel production tank. The identification sign stenciled onto the tank with half of the proper information. There was no plugs on the load lines. The dike was weathered; however, it meets containment requirements. The separator was in good working condition. There was one, 50 barrel brine tank next to a vertical drip tank at the sales flow line. The 7 day production chart was located next to the sales flow line. The well shares the production tank and separator with permit number 2-1668. The lease road was in stable condition with a locked wire steel line at the entrance. This well was placed in production prior to House Bill 278. I called Jamie Campbell at 440-858-7252. I instructed him to install the plugs on the load lines, remove enough weeds to expose the wellhead, and post the identification sign. I will re-inspect by 2/8/2013.
1427060378 2016-04-15 Production Wells Violations Noted My inspection found the well to be equipped with a plunger lift unit. The valves on the wellhead are closed. The plastic flow line is running above ground in multiple locations and needs to be buried. There is a section of poly flow line that is above ground 100 ft from the wellhead that has two repair clamps on it. There is a 10 ft area around the flow line repair that is saturated with oil and needs to be cleaned up. The tank battery consists of a 100 BBL production tank. The heated separator is outside of the tank battery with the proper spacing. The production chart in the meter box was last changed on 2/29/16. There is a 25 BBL tank sitting 20 ft outside of the tank battery that is not currently being used and needs to be removed from the location. There is a second separator on location for the sales line. The sales line separator is connected to a 50 BBL tank. The dike around the 50 BBL tank needs to be rebuilt. The proper identification was located on the tank battery. The identification on the wellhead was ilegible and needs replaced. The lease road is in stable condition and is secured by a wire gate. The tank battery and lease road are being shared by permit 2-1698.
1430357293 2013-09-10 UrbanProduction Wells No Violations I received a letter in reference to complaint ID #2500 from Attorney Thomas Carey, Jr. representing the landowner, who had concerns about the condition of a well site on his property. My inspection found the well was in production. The tank battery, separator, vertical separator, and both wells were engulfed with overgrown weeds. There were small trees growing next to the flow line and stairs at the production tank and around the well. I had to tie orange tape to mark the location of the well. I researched our database and found the annual production reports were up to date. I called Valerie Dunn of Well Completion Services at 440-858-2343. I informed her a complaint was filed concerning the condition of the well site. I told her to have the weeds and small trees cut down at the tank battery, separators, and both wells by 10/23/2013. I noticed a plug was placed on the load line and the stenciled identification sign had all of the correct information per my request on 1/28/2013. I took photos of the entire well site.
PL4084 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1427060378 US-OH-112453 2016-06-14 Failure to properly bury pipeline
1427060378 US-OH-112454 2016-06-14 Well operation causing pollution and contamination
1427060378 US-OH-112455 2016-06-14 Failure to legibly identify well

For data sources see[9]

References