Well Details

Well ID: 34-155-23232
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Liberty Township
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: CHEYENNE UNIT
License Status: Producing
License Date: 1988-09-30
Spud Date: 1988-10-03
Spud Drilling Contractor: SHERMAN DRLG
Final Drill Date: 1988-10-07
Well Total Depth: 5125.00 ft
Configuration: Vertical
Latitude: 41.170000
Longitude: -80.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1988-09-30 Issued Date 9/30/88 Expired Date 9/30/89 Acres 0081350 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05125 Proposed Drill Depth 05125
Original Spud 1988-10-03 CHG. ACG. 2-24-90
Completed 1988-10-07 CHG. ACG. 2-24-90
Reached Total Depth 1988-10-07 CHG. ACG. 2-24-90
Construction Permit Expires 1989-09-30 CHG. ACG. 2-24-90
Completion Report Received 1989-12-22 CHG. ACG. 2-24-90
CO 1990-05-01 2456 SIMCO EXPLORATION CORP GeoDate 9/30/88
Record Last Modified 2017-02-15 CHG. ACG. 2-24-90

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4875 4978 0
4875 4978 0
2006-09-11 4908 4932 2
4908 4932 2
4875 4978 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 FRAC:WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1990 OHIO VALLEY ENERGY SYSTEMS COR 12927.00 287.00 167
1991 OHIO VALLEY ENERGY SYSTEMS COR 13060.00 349.00 364
1992 OHIO VALLEY ENERGY SYSTEMS COR 12756.00 116.00 365
1993 OHIO VALLEY ENERGY SYSTEMS COR 11102.00 202.00 365
1994 OHIO VALLEY ENERGY SYSTEMS COR 8785.00 141.00 365
1995 OHIO VALLEY ENERGY SYSTEMS COR 7466.00 94.00 365
1996 OHIO VALLEY ENERGY SYSTEMS COR 5029.00 47.00 364
1997 OHIO VALLEY ENERGY SYSTEMS COR 4504.00 63.00 364
1998 OHIO VALLEY ENERGY SYSTEMS COR 5402.00 62.00 301
1999 OHIO VALLEY ENERGY SYSTEMS COR 5239.00 49.00 365
2000 OHIO VALLEY ENERGY SYSTEMS COR 4667.00 131.00 365
2001 OHIO VALLEY ENERGY SYSTEMS COR 4282.00 57.00 364
2002 OHIO VALLEY ENERGY SYSTEMS COR 3874.00 58.00 364
2003 OHIO VALLEY ENERGY SYSTEMS COR 4110.00 44.00 364
2004 OHIO VALLEY ENERGY SYSTEMS COR 4225.00 57.00 364
2005 OHIO VALLEY ENERGY SYSTEMS COR 4154.00 60.00 364
2006 OHIO VALLEY ENERGY SYSTEMS COR 2386.00 0.00 364
2007 OHIO VALLEY ENERGY SYSTEMS COR 2166.00 0.00 364
2008 OHIO VALLEY ENERGY SYSTEMS COR 1522.00 66.00 365
2009 OHIO VALLEY ENERGY SYSTEMS COR 1493.00 0.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 1264.00 0.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 1933.00 0.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 3185.00 105.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 2623.00 58.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 2489.00 0.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 2667.00 61.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 1561.00 19.00 249
2017 OHIO VALLEY ENERGY SYSTEMS COR 1152.00 0.00 158
2018 OHIO VALLEY ENERGY SYSTEMS COR 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1990 OHIO VALLEY ENERGY SYSTEMS COR Brine 80 167
1991 OHIO VALLEY ENERGY SYSTEMS COR Brine 130 364
1992 OHIO VALLEY ENERGY SYSTEMS COR Brine 116 365
1993 OHIO VALLEY ENERGY SYSTEMS COR Brine 69 365
1994 OHIO VALLEY ENERGY SYSTEMS COR Brine 40 365
1995 OHIO VALLEY ENERGY SYSTEMS COR Brine 8 365
1996 OHIO VALLEY ENERGY SYSTEMS COR Brine 43 364
1997 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
1998 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 301
1999 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2000 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2001 OHIO VALLEY ENERGY SYSTEMS COR Brine 364
2002 OHIO VALLEY ENERGY SYSTEMS COR Brine 35 364
2003 OHIO VALLEY ENERGY SYSTEMS COR Brine 45 364
2004 OHIO VALLEY ENERGY SYSTEMS COR Brine 15 364
2005 OHIO VALLEY ENERGY SYSTEMS COR Brine 36 364
2006 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2007 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 35 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 43 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 38 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 29 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 20 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 54 249
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 158
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 22 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1814819996 2013-4-16 0:00: UP No Violations 0.50
0000PL3264 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1162616345 2019-02-27 UrbanProduction Wells No Violations I conducted an inspection on this well, regarding a call received on the One Call line regarding a gas release from a pop-off valve, at the tank battery separator location. During this inspection, the well was equipped with a plunger lift assembly. The gate valve on the tubing and the valve on the 2 inch flow line were closed. The well was not in production, at the time of this inspection. The well had legible identification and was surrounded by tall, landscape grasses. The tank battery was comprised of one 100 BBL tank, one 50 BBL tank, and a mechanical separator. Valves on the separator were open and a new pop-off valve appeared to be installed on the outlet line. The diked tank battery was fenced with a locked man door. Legible identification was present at the tank battery. The lease access was stable and located off the northwest corner in the church parking lot. I contacted Ohio Valley Energy System Corp and spoke with Rick Little regarding the gas release incident. Mr. Little stated that a new pop-off valve and murphy switch would be installed at the well location to monitor line pressure, prior to entering the Dominion gathering line. At the time of this inspection, some of the additional equipment had not been installed and that was why the well was currently shut-in.
1814819996 2013-04-16 UrbanProduction Wells No Violations My inspection found the well in production. The well was equipped with a plunger lift unit. The tank battery contained one, 100 barrel production tank, one, 50 barrel brine tank, and a separator. It was surrounded by a chain link fence with the gate off the hinges. There were plugs on the load line. The was an identification sign, but the wrong permit number. The lease road was the parking lot of the church. I called Don Nething at 330-283-5758. I told Don to re-install the gate with a lock and put the correct permit number on the identification sign.
PL3264 PL No Violations

For data sources see[9]

References