X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23949

Well Details

Well ID: 34-155-23949
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: VALLEY VIEW
License Status: Producing
License Date: 2008-08-08
Spud Date: 2008-08-10
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-08-16
Well Total Depth: 5348.00 ft
Configuration: Vertical
Latitude: 41.160000
Longitude: -80.580000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-07-29 Proposed Formations:CLINTON, Issued Date:7/29/2008, Expired Date:7/29/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2008-08-08 Proposed Formations:CLINTON, Issued Date:8/8/2008, Expired Date:8/8/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-08-16
Completion Report Received 2009-03-06
Construction Permit Expires 2009-08-08
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-04 5006 5086 40
2009-06-04 5171 5177 12
5006 5086 40
5171 5177 12
5006 5086 40

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 20 0 48200

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PAC DRILLING LLC 4166.00 182.00 73
2009 PAC DRILLING LLC 23166.00 500.00 356
2010 PAC DRILLING LLC 19510.00 198.00 339
2011 PAC DRILLING LLC 8341.00 183.00 339
2012 PAC DRILLING LLC 5557.00 159.00 338
2013 PAC DRILLING LLC 4579.00 150.00 365
2014 PAC DRILLING LLC 6915.00 109.00 360
2015 PAC DRILLING LLC 3458.00 50.00 360
2016 PAC DRILLING LLC 2549.00 44.00 358
2017 PAC DRILLING LLC 2180.00 96.00 358
2018 PAC DRILLING LLC 2024.00 103.00 358

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PAC DRILLING LLC Brine 0 73
2009 PAC DRILLING LLC Brine 0 356
2010 PAC DRILLING LLC Brine 0 339
2011 PAC DRILLING LLC Brine 0 339
2012 PAC DRILLING LLC Brine 0 338
2013 PAC DRILLING LLC Brine 32 365
2014 PAC DRILLING LLC Brine 26 360
2015 PAC DRILLING LLC Brine 40 360
2016 PAC DRILLING LLC Brine 0 358
2017 PAC DRILLING LLC Brine 0 358
2018 PAC DRILLING LLC Brine 15 358

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1762785835 2020-3-27 0:00: UP No Violations
-1908467271 2016-7-20 0:00: UP No Violations 1.00
-591070604 2018-5-14 0:00: UP No Violations
0279818062 2017-07-12 UrbanProduction Wells No Violations

-up lines have plugs, but no locks. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--3951 and 2-3957.

The equipment on the pad consists of the following:



0517845675 2008-07-31 Drill / Deepen / Reopen No Violations Capstar moving on site .
0591070604 2018-05-14 UrbanProduction Wells Violations Noted At the time of this inspection, the well was equipped with a plunger lift assembly and the annulus and flow line valves were open. The wooden fence that surrounds the well needs repaired. Parts of it are missing and identification needs posted at the well. The diked tank battery has three storage tanks and a separator. The pick-up lines have plugs and the valve handles have been removed. The 210 BBL storage tanks are missing the required urban safety equipment. There was an identification sign posted on the wooden fence at the tank battery, but no lock on the fence. Parts of the tank battery fence need repaired and are falling down. The identification sign was missing the required information per 1501:9-9-05(E)(1)(a-e). The tank battery was shared with wells 2-3951 and 2-3957. The access was stable with a closed gate but no signage on the gate.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 3) Install signage at the well and lease gate per 1501:9-9-05(E)(1)(a-i). 4) Install a lock on the tank battery fence per 1501:9-9-05(E)(3).

1233853262 2008-11-10 Preliminary Restoration No Violations Inspection showed no violations . Drilling pits have been closed, also wellsite has been graded .
1444384034 2012-09-05 UrbanProduction Wells No Violations I completed an urban production inspection. My inspection found the well surrounded by a board-on-board fence and the proper identification posted. The tank battery was surrounded by a board-on-board fence and contained two 210 barrel storage tanks, one 50 barrel brine storage tank, the proper identification posted, and a separator. I noticed no visible spills or leaks. The lease road was in good condition. This well shares a lease road and tank battery with permit numbers 2-3949 and 2-3951. Inspection passed.
1453897029 2016-01-21 UrbanProduction Wells Violations Noted I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. There is a wooden fence with missing boards and no lock around the well. There is no identification sign at the well. The tank battery has two 210 barrels production tanks, a 50 barrel poly brine tank, and a mechanical separator. A dike surrounds the tank battery. An identification sign is posted at the tank battery. A wooden fence with no lock surrounds the tank battery. The lease road is in stable condition with a locked gate at the entrance. The tank battery is shared with permit number 2-3951 and 2-3957. I spoke with Rusty Hornhill, PACs well tender. I told Mr. Hornhill a compliance notice would be issued for failure to secure the fence around the tank battery and well with locks, replace missing board and no identification posted at the well. I told Mr. Hornhill a follow-up inspection would be conducted by February 8, 2016.
1478529093 2016-11-07 Production Wells No Violations

-door; however, the latch is missing hardware making it unsecure. I spoke with Rusty Hornhill, well tender with PAC Drilling.

PAC Drilling will: Activated charcoal filters Lightning arrestors Repair the latch to secure the man-door at the tank battery Install locks on the load lines or remove the valve handles

The equipment on the site consists of the following:



Low-pressure relief valve Tank hatch lids with functioning seal and lock

On 12/13/2016, Northeast Regional Supervisor Tom Hill and I met with Justin Caldwell, co-owner of PAC Drilling, and Rusty Hornhill, well tender for PAC Drilling concerning the missing required urban safety equipment on 31 PAC Drilling wells in Hubbard and Liberty Townships. Mr. Caldwell has been given a document listing the wells with the missing the urban safety equipment. PAC Drilling is to submit a schedule for equipment installation for review and approval by the Division of Oil & Gas.

1660572302 2016-03-07 UrbanProduction Wells No Violations I was on location in reference to compliance notice #1453897029. During my inspection, I found fence around the well has not been repaired. There are locks on the fences around the tank battery and well. A new identification sign has been installed.
1908467271 2016-07-20 UrbanProduction Wells No Violations I was on location to assess compliance notice # 1453897029. At the time of my inspection, I found the wooden fence surrounding the well repaired. There are locks and identification signs posted at the well and tank battery. There are no further violations at this time.
1937828068 2019-03-08 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 591070604, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the wooden fence that surrounds the well has been repaired, however identification still needs posted at the well. The 210 BBL storage tanks now have installed the required urban safety equipment. The wooden fence surrounding the tank battery has no way to secure the man door and needs to be secured and locked. The areas of the wooden fence that previously needed repaired have been repaired. The identification sign has been amended with the required information per 1501:9-9-05(E)(1)(a-e). The access gate was present but no identification has been installed on the gate.

PAC needs to: 1) Install signage at the well and lease gate per 1501:9-9-05(E)(1)(a-i). 2) Install a lock on the tank battery fence per 1501:9-9-05(E)(3).

279818062 2017-7-12 0:00: UP No Violations 0.40
517845675 2008-7-31 0:00: DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0591070604 US-OH-126652 2018-06-05 9-05E1 ID (a-i)
0591070604 US-OH-126653 2018-06-05 9-05E3 LOCKS
0591070604 US-OH-126654 2018-06-05 9-05E4 TANKS (a-i)
1453897029 US-OH-113129 2016-11-07 ID (a-i)
1453897029 US-OH-113130 2016-11-07 FENCING (a-d)
1453897029 US-OH-113131 2016-11-07 LOCKS

For data sources see[9]

References