X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23951

Well Details

Well ID: 34-155-23951
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: VALLEY VIEW
License Status: Producing
License Date: 2008-07-30
Spud Date: 2008-08-01
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-08-08
Well Total Depth: 5348.00 ft
Configuration: Vertical
Latitude: 41.160000
Longitude: -80.580000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-07-30 Proposed Formations:CLINTON, Issued Date:7/30/2008, Expired Date:7/30/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-08-08
Completion Report Received 2009-03-06
Construction Permit Expires 2009-07-30
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-04 5046 5116 50
5046 5116 50
5046 5116 50

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 20 0 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PAC DRILLING LLC 4166.00 182.00 73
2009 PAC DRILLING LLC 23166.00 500.00 356
2010 PAC DRILLING LLC 19510.00 198.00 339
2011 PAC DRILLING LLC 6456.00 141.00 339
2012 PAC DRILLING LLC 5557.00 159.00 338
2013 PAC DRILLING LLC 4579.00 150.00 365
2014 PAC DRILLING LLC 6916.00 109.00 360
2015 PAC DRILLING LLC 3458.00 50.00 360
2016 PAC DRILLING LLC 2549.00 44.00 358
2017 PAC DRILLING LLC 2180.00 96.00 358
2018 PAC DRILLING LLC 2024.00 103.00 358

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PAC DRILLING LLC Brine 0 73
2009 PAC DRILLING LLC Brine 0 356
2010 PAC DRILLING LLC Brine 0 339
2011 PAC DRILLING LLC Brine 0 339
2012 PAC DRILLING LLC Brine 0 338
2013 PAC DRILLING LLC Brine 32 365
2014 PAC DRILLING LLC Brine 26 360
2015 PAC DRILLING LLC Brine 40 360
2016 PAC DRILLING LLC Brine 0 358
2017 PAC DRILLING LLC Brine 0 358
2018 PAC DRILLING LLC Brine 15 358

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-20332127 2017-4-24 0:00: UP No Violations 0.50
-37288625 2019-3-8 0:00:0 UP No Violations
0020332127 2017-04-24 UrbanProduction Wells No Violations

-up line has a plug. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--3949 and 2-3957.

The equipment on the pad consists of the following:



0037288625 2019-03-08 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 899770143, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the wooden fence that surrounds the well still needs repaired. Parts of it are missing and identification needs posted at the well. The 210 BBL storage tanks now have installed the required urban safety equipment. The wooden fence surrounding the tank battery has no way to secure the man door and needs to be secured and locked. The areas of the wooden fence that previously needed repaired have been repaired. The identification sign has been amended with the required information per 1501:9-9-05(E)(1)(a-e). The access gate was present but no identification has been installed on the gate.

PAC needs to: 1) Install signage at the well and lease gate per 1501:9-9-05(E)(1)(a-i). 2) Install a lock on the tank battery fence per 1501:9-9-05(E)(3). 3) Repair the fencing around the well.

0111664155 2008-08-07 Drill / Deepen / Reopen No Violations Capstar , depth at 5120 , Repairing rig .
0375020244 2012-09-05 UrbanPreliminary Restoration No Violations I completed an Urban Preliminary Restoration inspection. My inspection found the well surrounded by a board-on-board fence and the proper identification posted. The tank battery was surrounded by a board-on-board fence and contained two 210 barrel storage tanks, one 50 barrel brine storage tank, the proper identification posted, and a separator. The production equipment had the proper spacing. The site has been graded and seeded to prevent erosion and sedimentation. This well shares a lease road and tank battery with permit numbers 2-3949 and 2-3957. Inspection passed.
0899770143 2018-05-14 UrbanProduction Wells Violations Noted At the time of this inspection, the well was equipped with a plunger lift assembly and the annulus and flow line valves were open. The wooden fence that surrounds the well needs repaired. Parts of it are missing and identification needs posted at the well. The diked tank battery has three storage tanks and a separator. The pick-up lines have plugs and the valve handles have been removed. The 210 BBL storage tanks are missing the required urban safety equipment. There was an identification sign posted on the wooden fence at the tank battery, but no lock on the fence. Parts of the tank battery fence need repaired and are falling down. The identification sign was missing the required information per 1501:9-9-05(E)(1)(a-e). The tank battery was shared with wells 2-3957 and 2-3949. The access was stable with a closed gate but no signage on the gate.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 3) Install signage at the well and lease gate per 1501:9-9-05(E)(1)(a-i). 4) Install a lock on the tank battery fence per 1501:9-9-05(E)(3).

0932665890 2016-11-07 UrbanProduction Wells No Violations

-door; however, the latch is missing hardware making it unsecure. I spoke with Rusty Hornhill, well tender with PAC Drilling.

PAC Drilling will: Activated charcoal filters Lightning arrestors Repair the latch to secure the man-door at the tank battery Install locks on the load lines or remove the valve handles

The equipment on the site consists of the following:



Low-pressure relief valve Tank hatch lids with functioning seal and lock

On 12/13/2016, Northeast Regional Supervisor Tom Hill and I met with Justin Caldwell, co-owner of PAC Drilling, and Rusty Hornhill, well tender for PAC Drilling concerning the missing required urban safety equipment on 31 PAC Drilling wells in Hubbard and Liberty Townships. Mr. Caldwell has been given a document listing the wells with the missing the urban safety equipment. PAC Drilling is to submit a schedule for equipment installation for review and approval by the Division of Oil & Gas.

111664155 2008-8-7 0:00:0 DD No Violations
1215314401 2016-03-07 UrbanProduction Wells No Violations I was on location in reference to compliance notice #1453820941. During my inspection, I found new locks on the fences around the tank battery and well. A new identification sign has been posted. There are no further violations at this time.
1309175435 2019-7-2 0:00:0 UP No Violations
1453820941 2016-01-21 UrbanProduction Wells Violations Noted I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. There is a locked wooden fence around the well. There is no identification sign at the well. The tank battery has two 210 barrels production tanks, a 50 barrel poly brine tank, and a mechanical separator. A dike surrounds the tank battery. An identification sign is posted at the tank battery. A wooden fence with no lock surrounds the tank battery. The lease road is in stable condition with a locked gate at the entrance. The tank battery is shared with permit number 2-3949 and 2-3957. I spoke with Rusty Hornhill, PACs well tender. I told Mr. Hornhill a compliance notice would be issued for failure to secure the fence around the tank battery with a lock and no identification posted at the well. I told Mr. Hornhill a follow-up inspection would be conducted by February 8, 2016.
2095333054 2008-08-04 Drill / Deepen / Reopen No Violations Case# 08-003 , Capstar drilling at 3450 . I found no violations per noise complaint . RESOLVED .
375020244 2012-9-5 0:00:0 UL No Violations 1.00
899770143 2018-5-14 0:00: UP No Violations
932665890 2016-11-7 0:00: UP No Violations 0.30

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0899770143 US-OH-130255 2018-06-05 9-05E1 ID (a-i)
0899770143 US-OH-130256 2018-06-05 9-05E3 LOCKS
0899770143 US-OH-130257 2018-06-05 9-05E4 TANKS (a-i)
1453820941 US-OH-113127 2016-08-04 ID (a-i)
1453820941 US-OH-113128 2016-08-04 LOCKS

For data sources see[9]